FIREPLACE FRAMING
Firebox framing can be built before or after the appliance is set in place. Construct firebox framing following
Figures 9
through 12
and the chart below for your specific installation requirements.
See Figure 1 on Page 6
for firebox dimensions.
The framing headers may rest on the top of the firebox standoffs.
The firebox may be installed directly on a combustible floor or raised on a platform of an appropriate height. When the
firebox is installed directly on carpeting, tile, or other combustible material, other than wood flooring, the firebox shall be
installed on a metal or wood panel extending the full width and depth of the enclosure.
Figure 9 - Corner Installation
Figure 11 - Stud Location
Figure 10 - Inside Chase
Installation
Figure 12 - Recessed Installation
Do not fill spaces around firebox with
insulation or other materials. This
could cause a fire.
W
ARNING
Combustibles may not come any closer to the top of the
enclosure than the standoffs will allow.