Majestic 36MCUFD SERIES Скачать руководство пользователя страница 1

For  use  with  a  listed  gas-fired 

unvented decorative room heater 

not to exceed 40,000 BTU/hr. 

Do 

Not Build a Wood Fire.

READ AND SAVE THESE INSTRUCTIONS

WARNINGS

If the information in this manual is not followed exactly, 

a fire or explosion may result causing property damage, 

personal injury or loss of life.
–  Do  not  store  or  use  gasoline  or  other  flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

–  WHAT TO DO IF YOU SMELL GAS

  •  Do not try to light any appliance.

  •  Do not touch any electrical switch; do not use any 

phone in your building.

  •  Immediately call your gas supplier from a neighbor's 

phone. Follow the gas supplier's instructions.

  •  If you cannot reach your gas supplier, call the fire 

department.

–  Installation  and  service  must  be  performed  by 

a  qualified  installer,  service  agency  or  the  gas 

supplier.

MAGNUM

UNVENTED 

VENT-FREE FIREBOXES 

INSTALLATION AND 

OPERATING INSTRUCTIONS

Carefully review the instructions 

supplied with the decorative type 

unvented room heater for the mini-

mum fireplace size requirement.

DO NOT INSTALL AN APPLIANCE 

IN  THIS  FIREBOX  UNLESS  THIS 

FIREBOX  MEETS  THE  MINIMUM 

DIMENSIONS  REqUIRED  FOR 

THE INSTALLATION.

WARNINGS

If  the  information  in  this  manual  is  not  followed 

exactly,  a  fire  or  explosion  may  result  causing 

property damage, personal injury or loss of life.
–  Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any 

other appliance.

–  WHAT TO DO IF YOU SMELL GAS

  • Do not try to light any appliance.

  • Do not touch any electrical switch; do not use 

any phone in your building.

  • Immediately  call  your  gas  supplier  from  a 

neighbor's  phone.  Follow  the  gas  supplier's 

instructions.

  • If you cannot reach your gas supplier, call the 

fire department.

–  Installation and service  must be performed by 

a qualified installer, service agency or the gas 

supplier.

WARNINGS

MODELS: 36MCUFD, 42MCUFD SERIES

Содержание 36MCUFD SERIES

Страница 1: ...VENTED VENT FREE FIREBOXES INSTALLATION AND OPERATING INSTRUCTIONS Carefully review the instructions supplied with the decorative type unvented room heater for the mini mum fireplace size requirement Do not install an appliance in this firebox unless this firebox meets the minimum dimensions required for the installation WARNINGS If the information in this manual is not followed exactly a fire or ...

Страница 2: ...sions 6 Minimum Hearth Dimensions 7 Location of Firebox 7 Clearances and Height Requirements 8 Fireplace Framing 10 Gas Line Installation 12 Canopy Installation 13 Optional Equipment 14 Forced Air Kit 14 Brass or Chrome Trim 14 Optional Wide Canopy 14 Illustrated Parts Breakdown 15 Using Optional Outside Air Kit 16 Warranty Back Cover ...

Страница 3: ...PORTANT Read these instructions carefully before installing or trying to operate a vent free gas heater in this firebox IMPORTANT SAFETY INFORMATION 1 Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies 2 Children and adults should be alerted to the hazard of high surface temperature and should stay away to avoid burns or clothing ignition ...

Страница 4: ...inued use 20 Input ratings are shown in BTU per hour and are for elevations up to 2 000 feet For elevations above 2 000 feet input ratings should be reduced 4 percent for each 1 000 feet above sea level Refer to the National Fuel Gas Code 21 The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test press...

Страница 5: ...ws for canopy 2 Canopy 3 Installation and Operating Instructions What you will need for installation TOOLS BUILDING SUPPLIES Phillips screwdriver Square Framing materials Hammer Piping complying with local codes Wall finishing materials Saw and or sabersaw Tee joint Caulking material noncombustible Level Pipe wrench Fireplace surround materials noncombustible Measuring tape Pliers Electric drill a...

Страница 6: ...s with fan kit Electrical connections should only be performed by an experi enced licensed certified tradesman 3 Plumb gas line Gas connections should only be performed by an experienced licensed certified tradesman 4 Install vent free gas log heater per the instructions provided with the vent free gas log heater 5 Complete finish wall material surround and optional hearth extension to your indivi...

Страница 7: ...aused by kitchen exhaust fans ceiling fans return air registers for forced air furnaces air conditioners windows or doors Installation must provide adequate ventilation and combustion air DO NOT INSTALL THIS FIREBOX IN A BEDROOM OR BATHROOM Location should be out of high traffic or windy or drafty areas DO NOT INSTALLWHERE CURTAINS FURNITURE CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42 FRO...

Страница 8: ...nst a combustible back wall Figure 4 Clearance and Height Requirements 4 Floor clearance This inner chamber firebox floor must be installed at least 6 above any combustible flooring mate rial such as carpeting or asphalt tile which is closer than 14 to the base of the firebox See Figure 5 Or The inner chamber firebox floor may be installed nearer to the floor if a minimum of 14 of noncombustible m...

Страница 9: ...nstalled it must meet the clearance requirements as shown in Figure 7A However if lower mantel height is desired see page 15 and Figure 7B Figure 7A Mantel Clearances Figure 7B Mantel Clearances for Wide Profile Canopy Only FIREPLACE WALL COMBUSTIBLE MATERIAL AREA HOOD Top View Figure 8 Mantel Clearances CLEARANCES and HEIGHT REQUIREMENTS ...

Страница 10: ...ppropriate height When the firebox is installed directly on carpeting tile or other combustible material other than wood flooring the firebox shall be installed on a metal or wood panel extending the full width and depth of the enclosure Figure 9 Corner Installation Figure 11 Stud Location Figure 10 Inside Chase Installation Figure 12 Recessed Installation Do not fill spaces around firebox with in...

Страница 11: ...side framing members using 8d nails or other suitable fasteners See Figure 14 5 The canopy must be installed for safe operation of the heater See page 13 for canopy installation details When finishing a custom cabinet mantel or other built in enclosure the opening size to accommodate the fireplace with trim installed is as follows Figure 13 Custom Cabinet Figure 14 Location of Nailing Flanges The ...

Страница 12: ...hrough trap to the heater controls and burners Failure to do so could prevent the heater from operating reliably Consult applicable codes An external regulator must be used on all propane L P G heaters in addition to the regulator fitted to the heater to reduce the supply tank pressure to 13 w c maximum Any copper tubing used to supply propane L P G from the tank must be internally tinned Note Whe...

Страница 13: ...the side frames See Figure 15 2 Align the canopy with the holes in the top frame 3 Replace the screws previously removed 4 Tighten side screws Make sure the canopy is level and secure The firebox canopy must not be modified or replaced with a canopy that may be provided with the unvented decorative room heater WARNING Close fireplace screen panel before operating a decorative type unvented room he...

Страница 14: ...ING Any of the original wire as supplied with the fireplace must be replaced Contact dealer for proper replacement wiring harness see parts list for part number 120 volts 60Hz 1 amps Electrical power cord plug can be routed to exit the 36MCUFD 42MCUFD on either the left side or the right side Remove cord protector from side of unit route power cord through hole opposite side Reinstall cord protect...

Страница 15: ... Panel 2 26D4562 26D45622 3 Screen Rod 2 26D0132K 26D0133K ACCESSORIES in KITS 1 Standard Brass Canopy 1 BRCU36 BRCU42 1 Wide Brass Canopy 1 BRC36 BRC42 4 Blower w Rheostat 1 BLOTMC BLOTMC 5 Brass Trim Curved Design 1 BRTKM36 BRTKM42 5 Pewter Trim Curved Design 1 PWTKM36 PWTKM42 5 Black Trim Curved Design 1 BLTKM36 BLTKM42 6 Outside Air Kit 1 AK 4 AK 4 ...

Страница 16: ...age space 5 Locate air supply inlet at least 3 away from any applaince vent terminal 6 Avoid extremely long runs and numerous turns in the duct leading from the fireplace to the combustion air assembly These conditions increase the resistance to the free flow of air through the duct See Figures 17 through 20 for methods of installing the outside air for combustion assemblies Figure 17 Basement Ins...

Страница 17: ...g collar with duct clamp or screws See Figure 22 DO NOT remove the cover if the outside air will not be connected WARNING Figure 21 Attaching Outside Air Starting Collar and Insulation Ring to Left Side of Fireplace Figure 22 Attaching Outside Duct to Starting Collar Insulation Ring AK 4 Starting Collar Sheet Meal Screws Left Side of Fireplace Shorter End of Air Starting Collar Air Starting Collar...

Страница 18: ...ll Note If the wall covering is brick or stone use appropriate masonry fasteners If necessary splice the duct Use a model 403 duct connector to splice duct sections Installing model 403 duct connector 1 Push insulation back approximately 2 from the end of each duct 2 Slip each duct over duct connector until an equal length of connector extends into each duct 3 Place duct clamp over the end of each...

Страница 19: ...ed Lifetime Warranty will also be void if the appliance is not operated and maintained according to the operating instructions supplied with the appliance and does not extend to 1 firebox burner assembly damage by accident neglect misuse abuse alteration negligence of others including the installation thereof by unqualified installers 2 the costs of removal reinstallation or transportation of defe...

Страница 20: ...AUGUST 2008 26D4750 Rev 9 MHSC 149 Cleveland Drive Paris Kentucky 40361 www mhsc com ...