Majestic 360DVS2 Скачать руководство пользователя страница 10

10

360 DVS Series Direct Vent Fireplaces

10006326

A hearth is not mandatory; however, for aesthetic 

purposes, we recommend installing a noncombustible 

hearth that projects out 12” (305mm) or more from the 

front of the fireplace.

Cold climate installation recommendation:  

When installing this unit against a noninsu-

lated exterior wall or chase, it is mandatory 

the outer walls be insulated to conform to 

applicable insulation codes.  

Hearth

Final Finishing

1.  Choose the unit location.
2.  Place the unit into position and secure it to the floor 

with 1

¹⁄₂

” (38mm) screws or nails. Holes to secure 

the unit to the floor are located behind the access 

door grille on the left and right sides of the unit.

3.  Frame in the fireplace with a header across the top. 

It is important to allow for the finished wall face when 

setting the depth of the frame.

4.  Drywall (sheetrock) or wood material may be placed 

with a zero clearance to the top edges of the appli-

ance when finishing walls above sides of the appli-

ance with glass windows. 

NOTE:  Attach wall finish-

ing to constructed frame, not the appliance.

5.  On 360DVSL and 360DVSR, drywall, wood, or wood 

molding may be placed with zero clearance to the 

rear wall of the unit, along the vertical edge formed 

by the standoffs, to intersection of the rear wall, to 

the side wall having the small glass window. 

NOTE:  

Attach wall finishing to constructed frame, not 

the appliance.

Framing & Finishing

Noncombustible materials such as brick or tile may be 

extended over the edges of the face of the appliance. 

DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the 

brick or tile will have to be installed flush with the edges 

of the appliance.

 

 

 

 

 

Max. 

Min.

 

 

 

 

 

Input 

Input

 

Model 

Fuel 

Gas Control 

BTU/h 

BTU/h

  360DVS2RN  Nat 

Millivolt 

38,000 

26,600

  360DVS2RP  Prop 

Millivolt 

38,000 

28,500

  360DVS2EN  Nat 

24V Hi/Lo 

38,000 

26,600

  360DVS2EP  Prop 

24V Hi/Lo 

38,000 

28,500

  360DVS3RN  Nat 

Millivolt 

38,000 

26,600

  360DVS3RP  Prop 

Millivolt 

38,000 

28,500

  360DVS3EN  Nat 

24V Hi/Lo 

38,000 

26,600

  360DVS3EP  Prop 

24V Hi/Lo 

38,000 

28,500

  360DVSLRN  Nat 

Millivolt 

38,000 

26,600

  360DVSLRP  Prop 

Millivolt 

38,000 

28,500

  360DVSRRN  Nat 

Millivolt 

38,000 

26,600

  360DVSRRP  Prop 

Millivolt 

38,000 

28,500

Gas Specifications

Gas Inlet & Manifold Pressures

 

 

Natural 

LP (Propane)

 

Inlet Minimum 

4.5” w.c. 

11.0” w.c.

  Inlet Maximum 

14.0” w.c. 

14.0” w.c.

  Manifold Pressure 

3.5” w.c. 

10.0” w.c.

Input ratings are shown in BTU per hour and are 

certified without deration for elevations up to 

4,500 feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, 

installations must be in accordance with the 

current ANSI Z223.1/NFPA 54 and/or local codes 

having jurisdiction. 
In Canada, please consult provincial and/or local 

authorities having jurisdiction for installations 

above 4,500 feet (1,370 m).

When purging the gas lines, the window 

frame assembly must be removed.

The gas pipeline can be brought in through the vent 

end of the fireplace as well as the bottom. Knockouts  

 (to allow gas pipe installation and testing any gas con-

nection) are provided on the bottom behind the valve. 

It is most convenient to bring the gas line in from the 

vent end of the valve, as this allows fan installation or 

removal without disconnecting the gas line.
The gas line connection can be made with properly 

tinned 3/8” copper tubing, 3/8” rigid pipe, or an ap-

proved flex connector. Since some municipalities have 

additional local codes, it is always best to consult your 

local authority and the CSA-B149.1 installation codes.
For USA installations, consult the current National Fuel 

Gas Code, ANSI Z223.1/NFPA 54.  

Always check for gas leaks with a mild 

soap and water solution. Do not use an 

open flame for leak testing.

The gas control is equipped with a captured-screw type 

pressure test point, therefore it is not necessary to pro-

vide a 1/8” test point upstream of the control.

Gas Line Installation

Содержание 360DVS2

Страница 1: ...y electric switch do not use any phone in your building Immediately call your gas supplier from your neighbor s phone Follow the gas suppliers instructions If you cannot reach your gas supplier call t...

Страница 2: ...lation 17 Below Grade Installation 20 Vertical Through the Roof Application Installation 21 Twist Lock Venting Components 23 Operating Instructions Glass Information 24 Louvre Removal 24 Window Frame...

Страница 3: ...lventilated open all windows Itisrecommendedthatyouburnyour fireplaceforatleast ten 10 hours the first time you use it If the optional fan kit has been installed place the fan switch in the OFF positi...

Страница 4: ...the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS Inspe...

Страница 5: ...ine Access Electrical Access Gas Line Access J J K J J Fireplace Dimensions 360DVS2 Rear Vent Configuration Top Vent Configuration Fig 1a Fireplace specifications 360DVS2 Ref Rear Vent Configuration T...

Страница 6: ...replace Dimensions 360DVS3 306DVSL 360DVSR Rear Vent Configuration Top Vent Configuration Ref Rear Vent Configuration Top Vent Configuration A 38 968 mm 38 968 mm B 40 1032 mm 40 1032 mm C 24 610 mm 2...

Страница 7: ...nfiguration CFM121 CFM122 Framing Dimensions Ref Rear Vent Configuration Top Vent Configuration ROD 24 610 mm minus two times finishing material thickness to be even with face of unit ROH 38 981 mm No...

Страница 8: ...123 CFM124 Framing Dimensions Ref Rear Vent Configuration Top Vent Configuration Model 360DVS3 360DVSL R 360DVS3 360DVSL R ROD See Note 1 See Note 2 See Note 1 See Note 2 ROH 38 981 mm Not to be frame...

Страница 9: ...tibles A B C D E V W X Y Z CFM146 DV Mantel Chart 7 5 01 sta Louvre Assembly Top Fireplace Top of Combustion Chamber Bottom of Door Trim Mantel Shelf Mantel from Top Ref or Breast Plate Ref of Comb Ch...

Страница 10: ...at 24V Hi Lo 38 000 26 600 360DVS2EP Prop 24V Hi Lo 38 000 28 500 360DVS3RN Nat Millivolt 38 000 26 600 360DVS3RP Prop Millivolt 38 000 28 500 360DVS3EN Nat 24V Hi Lo 38 000 26 600 360DVS3EP Prop 24V...

Страница 11: ...g socket assembly from the EB 1 box 3 Feed the supply line in from the out through the elec trical knockout 4 Connect the ground wire of the supply line to the green screw of the socket assembly 5 Con...

Страница 12: ...is purpose NOTE When converting appliance to top vent ensure the insulation material referred to in step 3 is completely removed 4 Remove the 4 screws securing the flue cover plate to the top of the i...

Страница 13: ...TRANSFORMER 24 VAC HOT BLACK WHITE WALL SWITCH WHITE OFF 1 2 3 5 6 8 9 MV MV VP PV GRD 24V SENSE SPARK 24V ORANGE RED GREEN BLACK FP1225 Fig 12 Honeywell ignition module Your fireplace is approved to...

Страница 14: ...m above the meter regulator assy I Clearance to service regulator vent outlet 3 91cm 3 91cm J Clearance to nonmechanical air supply inlet 6 15cm for appliances 10 000 6 15cm for appliances to building...

Страница 15: ...ant Vaseline or similar substance on male end of twist lock pipe prior to assembly Male End Female End Screw Holes TWL100 Fig 15 Twist lock pipe joints Outside Corner Inside Corner Termination Clearan...

Страница 16: ...dewall vent graph showing the relationship between vertical and horizontal dimensions for a Direct Vent flue system Fig 16 Sidewall vent graph Rear Wall Application When installed as a rear vent unit...

Страница 17: ...the termination Vertical Sidewall Application It is very important the venting system maintain its bal ance between the combustion air intake and the flue gas exhaust certain limitations concerning v...

Страница 18: ...of 45 elbows permitted per installation is six 6 These elbows can be installed in either the vertical or horizontal run For each 45 elbow installed in the horizontal run the length of the horizontal r...

Страница 19: ...i e from the elbow to the outside wall face plus 2 51 mm or the distance required if installing a second 90 elbow Fig 27 Always install horizontal venting on a level plane X X FP1441 Fig 27 Horizonta...

Страница 20: ...exceeds 24 610 mm 1 Establish vent hole through the wall Fig 24 2 Remove soil to depth of about 16 406 mm below base of snorkel Install window well not supplied Refill hole with 12 305 mm of coarse gr...

Страница 21: ...l the maximum horizontal length must be reduced by 18 457 mm Example Maximum horizontal length Zero elbows 10 3 m 1 x 45 elbows 8 2 6 m 2 x 45 elbows 7 2 1 m A minimum of an 8 ft 2 43 m vertical rise...

Страница 22: ...orm collar and seal around the pipe 10 Add additional vent lengths for proper height Fig 32 11 Apply high temperature sealant to 4 and 7 collars of vertical vent termination and install CFM110 Typical...

Страница 23: ...K Sidewall Starter Kit Model 7TDVSKV Vertical Venting for 7TDVSKV A order 1 12 to 6 12 roof pitch for 7TDVSKV B order 7 12 to 12 12 roof pitch for 7TDVSKV F order flat roof Starter Kit Model 7TDVSKS S...

Страница 24: ...frame assembly up and away from the fireplace 7 To reinstall the window frame assembly reverse this procedure Front Window Frame Assembly 1 Remove the top and bottom louvre assembly 2 Remove the lowe...

Страница 25: ...logs by the number cast into the underside For correct operation of the fireplace the logs must be correctly placed in the sequence described below 1 Unpack the logs from the shipping carton The logs...

Страница 26: ...and separate it into small pieces then scatter it over burner tiles in a random fashion Do not pack down ember material leave it in a fluffy state Lava Rock Pt 10001454 Remove lav rock material from p...

Страница 27: ...t knob for SIT valve Flame Characteristics It is important to periodically perform a visual check of the pilot and burner flames Compare them to the pictorials illustrated below Figs 45 46 If the flam...

Страница 28: ...because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building I...

Страница 29: ...t call a qualified service technician Force or attempting repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service tec...

Страница 30: ...ot supplied must be used to conduct this test 3 Pilot burning no gas to A Wall switch or wires defective Check wall switch and wires for proper connections main burner Jumper wires across terminals at...

Страница 31: ...RES ARE GOOD AND PILOT BURNER ORIFICE IS NOT BLOCKED CHECK ELECTRICAL CONNECTIONS BETWEEN MODULE AND PILOT OPERATOR ON GAS CONTROL CHECK FOR 24VAC ACROSS PV MVPV TERMINALS ON MODULE IF VOLTAGE IS OKAY...

Страница 32: ...ce Piezo Ignitor Supply Line Hooked Up Shutoff Valve Open PILOT STAYS LIT For Air In The Lines Thermopile Needs A Min 325mv Adjust Pilot Flame Height All Wiring Connections Replace Thermopile Thermoco...

Страница 33: ...360DVS air shutter Air Shutter Retain ing Screws Air Shutters FP1447 Fig 47 Air shutter adjustment 8 SIT Top Convertible Pilot Gently lift off pilot hood from the pilot NOTE Do not remove the spring...

Страница 34: ...s used The only variations are in orifice sizes and component part numbers Your authorized service provider will en sure correct parts are used L O H I HV120 Honeywell valve conversion 9 24 02 djt Reg...

Страница 35: ...should be performed by a qualified technician 1 Turn off pilot light at gas valve side 2 Let fireplace cool if it has been running 3 Remove window frame assembly Refer to Window Frame Assembly Remova...

Страница 36: ...24 27 17 2 29 28 22 23 26 21 20 25 19 13 14 3a b 15a b 16a b 6326 360DVS parts 31a b 32 35 33 HI LO 34a b 25 36 37 30 1 1a 1b 1c 1d 1e 1f 1g Vermont Castings Group reserves the right to make changes i...

Страница 37: ...0002266 8 Pilot Hood SIT Top Convertible 10002385 10002385 10002385 10002385 Orifice Pilot PSE Nat 10001822 10001822 10001822 10001822 Orifice Pilot PSE Prop 10001823 10001823 10001823 10001823 Orific...

Страница 38: ...57 Air Inlet Cover Plate Assembly 10006174 10006174 10006174 10006174 Air Inlet Cover Plate Gasket 10006171 10006171 10006174 10006171 Flue Pipe Plate Assembly 10002554 10002554 10002554 10002554 Flue...

Страница 39: ...e power supply may be connected in two ways Method A Route the 6 lead fitted to the unit to a conveniently located wall socket Method B The EB I receptacle box Pt ZA1200 may be hard wired into the hou...

Страница 40: ...ll mounted thermostat control Decorative Trim Frame Kit The DV360TKMP Medium Trim Kit in polished brass is available for the 360DVS2 model only Each kit contains 4 polished brass trim pieces and the n...

Страница 41: ...41 360DVS Series Direct Vent Fireplaces 10006326...

Страница 42: ...42 360 DVS Series Direct Vent Fireplaces 10006326...

Страница 43: ...installation instructions The Limited Lifetime Warranty will also be void if the appliance is not operated and main tained according to the operating instructions supplied with the appliance and does...

Страница 44: ...83 84 65 360DVS3RN 62 4 83 84 65 360DVS3RP 62 4 83 84 65 360DVS3EN 62 4 83 84 65 360DVS3EP 62 4 83 84 65 360DVSLRN 62 4 83 84 65 306DVSLRP 62 4 83 84 65 360DVSLEN 62 4 83 84 65 360DVSLEP 62 4 83 84 65...

Отзывы: