DVBL7 Series Gas Fireplace
VeNtING INStaLLatIoN
VO584-100
Vent Opening
2/99 djt
Vent opening for Combustible walls
9
B\,
”
(244 mm)
Min.
Fireplace Hearth
Framing Detail
opening for Noncombustible wall
7
Z\x
”
(190 mm)
Fireplace Hearth
FP2293
Figure 16 -
Locate vent opening on wall.
9
B\,
”
(244 mm) Min.
VertICaL SIDewaLL INStaLLatIoN -
t-LoCK PIPe
Step 1
Locate vent opening on the wall. It may be necessary to
first position the fireplace and measure to obtain hole lo-
cation. Depending on whether the wall is combustible or
noncombustible, cut opening to size.
Figure 16
(For com-
bustible walls first frame in opening.)
Note:
When using flex vent, the opening will have to be
measured according to the 1/2” (13 mm) rise in 12” (305
mm) vent run.
Combustible walls:
Cut a 9
B\,
”H x 9
B\,
”W (244 x 244 mm)
hole through the exterior wall and frame as shown.
Figure
16
Noncombustible walls:
Hole opening must be 7
Z\x
” (191
mm) in diameter.
Step 2
Secure firestop to the inside frame, center in the 9
B\,
" x
9
B\,
" vent opening.
Step 3
Place fireplace into position. Measure the vertical height
(X) required from the base of the flue collars to the center
of the wall opening.
Figure 17
Step 4
Install the unitized T-Lock vent pipe to the appliance col-
lar, following T-Lock directions on Page 14. It is not neces-
sary to seal this connection. If a 45° elbow is being used
attach the elbow to the appliance in the same manner
then attach the venting to the elbow.
X
X
Figure 17 -
Vertical Height
Requirement
FP1181
IMPortaNt: Pipe can be twisted in either direction.
however, aLL PIPe MuSt Be rotateD IN the SaMe
DIreCtIoN.
Securing the joints with sheet metal screws is not re-
quired.
Step 5
Measure the horizontal length requirement including a 2”
(51 mm) overlap, i.e. from the elbow to the outside wall
face plus 2” (51 mm) (or the distance required if installing
a second 90° elbow).
Figure 18
always install horizontal venting on a level
plane.
X
X
Figure 18 -
Horizontal Length
Requirement
FP1182
Step 6
Use appropriate length of pipe sections - telescopic or
fixed - and install. The sections which go through the wall
are packaged with the starter kit, and can be cut to suit if
necessary.