UVS33/36 Vent-Free Heaters

20002211

Gas Specifications

 

Model 

Fuel  Gas Control  Max. 

Min.  Orifice 

Air

 

 

 

 

Input 

Input 

Size  Shutter

 

 

 

 

BTU/H   BTU/H 

 

Setting

  UVS33RN  Nat  Millivolt Hi/Lo  20,000  15,000 

#45 

1/16"  

   

 

 

 

 

 

Open

  UVS33RP  LP  Millivolt Hi/Lo  20,000  14,750 

#55 

Fully  

   

 

 

 

 

 

Open

  UVS33RN  Nat  Millivolt Hi/Lo  15,000  10,750 

#50 

Closed

  UVS33RP  LP  Millivolt Hi/Lo  15,000  11,000 

#56 

Fully  

   

 

 

 

 

 

Open*

  UVS33RN  Nat  Millivolt Hi/Lo  10,000 

7,500 

#52 

Closed

  UVS33RP  LP  Millivolt Hi/Lo  10,000 

8,000 

#62 

Fully  

   

 

 

 

 

 

Open*

  UVS36RN  Nat.  Millivolt Hi/Lo  25,000  17,500 

n/a 

Fully 

   

 

 

 

 

 

Open

  UVS36RP  LP  Millivolt Hi/Lo  25,000  18,750 

n/a 

Fully 

   

 

 

 

 

 

Open

    * Use air shutter in orifice bag without round holes.

3. Frame in heater with a header across the top.  It is 

important to allow for finished face when setting the 
depth of the frame. 

4. Attach heater to frame using adjustable frame drywall 

strips (located behind access door for shipping).  
Preset depth to suit facing material (adjustable to 
1/2", 5/8" or 3/4" depths). (Fig. 6)

5. Use existing screws in side of unit to attach drywall 

strip. Measure from face of heater to face of drywall 
strip to determine final depth. (Fig. 6)

FP1023

side nailing flange

1/27/00  djt

A
B

C

Adjustable Drywall Strip

(Nailing Flange)

 

Scew 

Drywall

  Position 

Depths

 

1/2" (13 mm)

 

5/8" (16 mm)

 

3/4" (19 mm)

Adjustable 1/2", 

5/8" & 3/4" Spac-

ing

FP1023

Fig. 6

  Adjustable drywall strip (nailing flange).

Framing

Framing can take place before or after the heater is set 
in place.  The framing should be positioned to accom-
modate the wall covering and facing material. Framing 
material should be 2x4 or heavier.  Framing headers 
may rest on top of heater.  (Refer to Page 3, Figure 1 
for heater and framing dimensions.) 

Insulating for Cold Climates

When a heater is installed in a chase or an outside wall, 
the enclosure should be insulated like any other wall 
of the home.  Insulation should be installed under the 
heater and on the inside of the exterior walls. (Fig. 7)  

NOTE:

 Insulating for cold climates is strictly a recom-

mendation and not a requirement. 

GF456

UVC

2/19/97

Insulation meth-

ods shown are 

optional for cold 

climate, not a 

requirement for 

unit operation.

Insulation

FP546

Fig. 7

  Insulating for cold climates.

Parts Identification

FP443a   

UVC33

12/18/99   djt

Nailing 

Flange

Gas 

Line Access

(both sides)

Top 

Louvre

Screen Panel

Logs and Burner

Firebox

Bottom Louvre

(Bottom access 

door, controls behind louvre)

FP443a

Fig. 8

  Parts identification.

Содержание UVS33RN

Страница 1: ... Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance What to Do If You Smell Gas Do not try to light any appliance Do not touch any electrical switch do not use any phone in your build ing Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas sup plier call the fire ...

Страница 2: ...1 Log Installation UVS36 11 Ember Material Placement 12 Lava Rock 12 First Firing 12 Odor During Operation 12 Flame Adjustment 12 Flame Characteristics 12 Lighting and Operating Instructions 14 Troubleshooting 15 Maintenance Cleaning the Standing Pilot Control System 16 Replacement Parts 17 Optional Accessories Fan Kits 19 Electrical Connection 19 Remote Controls 19 Outside Air Termination 19 Cera...

Страница 3: ...ibed in the National Fuel Gas Code ANSI Z 223 1 NFPA 54 Section 5 3 or applicable local codes Unusually tight construction is defined as construction where a Walls and ceilings exposed to the outside atmosphere have a continuous water vapor retarder with a rating of 1 perm 6 x 10 11 kg per pa sec m2 or less with openings gasketed or sealed and b Weather stripping has been added on openable windows ...

Страница 4: ...ccess 12 Rough Opening Depth 2 5 Outside Air Fig 1 UVS33 specifications and framing Fireplace Dimensions 20 36 34 32 5 2 Gas Line Access 2 Dia Finished Wall Thickness Rough Opening Height Rough Opening Width Electrical Cable Knockout 1 Dia 21 1 36 Electrical Box Knockout 2 Dia Electrical Cable Knockout 1 Dia 33 34 36 36 25 51 4 9 7 36 Gas Line Access 2 Dia 14 Rough Opening Depth 3 5 8 Outside Air 2...

Страница 5: ...local codes please match the correct orfice size and BTU s to corresponding room size This conversion must not be completed in the field Once final rate is established remaining orifices are to be discarded not left behind with the fireplace Orifice Conversion Instructions 1 Locate burner with tiles pilot shield and orifice 2 Unscrew two hex nuts connecting pilot shield to burner with tiles Move pilot sh...

Страница 6: ...1 mm D 13 343 mm Z 2 51 mm E 11 292 mm A B C D E V W X Y Z Fireplace CFM146 DV Mantel Chart 7 5 01 sta Top Louvre Assembly Top of Combustion Chamber Bottom of Door Trim Mantels Depending on the width of the mantel it may be in stalled higher or lower from the combustion chamber opening This also applies to the distance between the mantel leg if installed and the fireplace Refer to Fig ures 5a and 5...

Страница 7: ...depth Fig 6 FP1023 side nailing flange 1 27 00 djt A B C Adjustable Drywall Strip Nailing Flange Scew Drywall Position Depths A 1 2 13 mm B 5 8 16 mm C 3 4 19 mm Adjustable 1 2 5 8 3 4 Spac ing FP1023 Fig 6 Adjustable drywall strip nailing flange Framing Framing can take place before or after the heater is set in place The framing should be positioned to accom modate the wall covering and facing ma...

Страница 8: ...without disconnecting the gas line NOTE The gas line connection can be made with prop er 3 8 copper tubing 1 2 rigid pipe or an approved flex connector then reduced to 3 8 to the heater Because some municipalities have some additional local codes it is always best to consult your local authority Consult the current National Fuel Gas Code ANSI Z223 1 NFPA 54 Always check for gas leaks using a 50 50 ...

Страница 9: ... Hex Nuts Louvre Bracket FP1001 Fig 11 Louvre bracket EB1 Receptacle Hook Up 1 Remove 2 knockout Slide the electrical box back plate into the back and bottom lances clips while fitting the box connector into the knockout Fasten into place with fastening screws provided Fig 12 2 Connect the black positive wire to brass screw polarized side of the receptacle The white wire is connected to the chrome ...

Страница 10: ...et on either side of the frame lining up the screws with the pre punched holes Fig 14 Finishing CAUTION All joints between the finished wall and the heater surround top and sides may be sealed only with noncombustible material Only noncombustible material can be applied as facing to the heater surround the black painted face When finishing the heater never obstruct or modify the air inlet outlet top...

Страница 11: ...removal 12 99 Clamps Fireplace Front DV34 2 FP1000 install glass 12 99 Window Frame Pull Clamp Hook Push Clamp Handle FP1000 Window Frame 6 Lift off the window frame as shown in Figure 15 7 To reinstall window frame follow the above procedure in reverse Fig 16 Log Installation UVS33 1 Remove window frame See Window Frame section 2 Remove logs from packaging As with all plastic these are not toys a...

Страница 12: ... Place rear log BE8 on rear bracket ensure log is seated properly leveled and centered to the unit so the log will not move form side to side and is firmly positioned onto the bracket 4 Place front left log BE6 on top of burner left side Use log s bottom holes to locate it onto the left bracket log locator studs 5 Place front right log BE7 on top of burner right side Use log s bottom holes to locat...

Страница 13: ...important to periodically perform a visual check of the pilot and burner flames Compare them to Figures 19 or 20 If the flame patterns appear abnormal contact a qualified service provider for service and adjustment Fig 20 Approximate flame heights for UVS33 LG118 UVS33 log flames 12 20 99 djt LG118a UVS33 log flames at 15 000 BTU 12 22 99 djt LG118b UVS33 log flames at 10 000 BTU 12 22 99 djt LG118 LG...

Страница 14: ...ell all around the heater area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any fireplace Do not touch any electric switch Do not use any phone in your building Immediately call your gas supplier from a neigh bor s phone Follow the gas supplier s instruc tions To Turn Off Gas to Heater Ligh...

Страница 15: ...mopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve turn to pilot meter should read greater than 100mV If not replace Pilot Lights with Piezo Ignitor YES YES YES YES Pilot Stays Lit Pilot Lights Main Burner System OK START CHECK Valve is turned on Wall switch is not turned on Watch for grounded wires ...

Страница 16: ...burner gas orifice thermopile combination millivolt gas valve Most of these components may require only an occa sional checkup and cleaning and some may require ad justment If repair is necessary it should be performed by a qualified technician In order to properly clean the burner and pilot assembly turn off the gas to the unit remove the window frame panel and logs exposing the burner and pilot as...

Страница 17: ...nt Free Gas Room Heater Ref Description UVS33 UVS36 1 Complete Log Set 20002236 10000547 1a Top Left Log A20 BE9 1b Top Right Log A21 BE10 1c Rear Log A19 BE8 1d Front Left Log A17 BE6 1e Front Right Log A18 BE7 2 Lava Rock Package 55255 55255 3 Ceramic Tile Single 57803 57803 4 Burner w Tiles 20002198 20000075 5a Orifice Main Burner Natural 20 000 45 20002202 5b Orifice Main Burner LP 20 000 55 525...

Страница 18: ...LP 10 000 62 20002250 See Rating Plate 6 Fan w Bracket FK24 54103 54103 7 Electrical Cord 6ft 51865 51865 8 Speed control Knob 51882 51882 9 speed Control 51738 51738 10 Frame Window Assembly 20002139 10000148 11 Top Louvre Assembly 10000292 10000037 12 Bottom Louvre Assembly 10000293 10000038 13a Pilot Assembly natural 55464 55464 13b Pilot Assembly LP 55465 10001647 14 Cable Ignitor 20000101 200...

Страница 19: ...rician to carry out the installation If hard wiring the fan in using Method B following we strongly recommend the use of a licensed electrician 1 Open the lower louvre assembly Maneuver the fan bracket assembly around the gas valve and lines to locate the unit onto the screw studs on the back of the fireplace 2 Install the thermal sensor under the bottom of the firebox locating it over the two 10 mm...

Страница 20: ...d or broken Replacement glass complete with gasket is available through your CFM Corporation dealer and should only be installed by a licensed quali fied service person UVS 36GCFK 1 Turn unit OFF 2 Remove the top louvre Refer to Page 11 Figure 15 3 Remove the window frame Refer to Page 11 Figure 16 4 Remove the deflector firebox by removing the three 3 screws securing it to the firebox top Fig 22 5 In...

Страница 21: ...hinges 2 Remove the louvre assembly top 3 Assembly the Bay Window Kit according to the in structions supplied with the kit 4 Place the 2 pieces of ceramic refractory along the base of the bay window Fig 21 5 Hang the bay window assembly over the existing window frame assembly 6 Reinstall the louvre assembly top 7 Do not remove the existing window frame assembly Louvre Assem bly Top Bay Window Fram...

Страница 22: ...22 UVS33 36 Vent Free Heaters 20002211 ...

Страница 23: ...on the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this warranty is covered for six months or the remainder of the original warranty whichever is longest This warranty is limited to the repair of or replacement of part s found to be defective in material or ...

Страница 24: ... CFM Corporation 2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation ...

Отзывы: