Majestic fireplaces Sovereign SC36A Скачать руководство пользователя страница 2

2

SR/SC Series "A" Woodburning Fireplace

7412948

Safety Information

PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE.

IMPORTANT: Read all instructions and warnings carefully before starting installation.  Failure to
follow these instructions may result in a possible fire hazard and will void the warranty.

Description

The SR/SC Series "A" fireplaces are solid fuel, wood-
burning premium fireplaces. The SR36A/42A are radiant
clean-face models and the SC36A/42A are circulating
models with removable grilles (louvres). Both models
are fully insulated fireplaces.

Precautions

CFM Specialty Home Products fireplaces and compo-
nent parts have been highly tested and will operate
safely when installed in accordance with instructions
provided in this manual. Carefully read and understand
all instructions before beginning installation.

If you notice any damage to fireplace or component
parts, immediately report damage to your Majestic
Fireplaces dealer.

Only use CFM Specialty Home Products components or
the warranty will be voided and a fire hazard may be
created.

CFM Specialty Home Products warranty will be voided
by and CFM Specialty Home Products  disclaims any
responsibility for the following actions:

Installation of any damaged fireplace or
chimney component;

Modification of fireplace, chimney assembly or
any component parts thereof; 
(except for chase
flashings as detailed in Chimney Top installation
instructions).

Installation other than as instructed by CFM
Specialty Home Products; or

Installation and/or use of any component part
not manufactured or approved by CFM Spe-
cialty Home Products in combination or
assembly with a Majestic Fireplaces fireplace
system, notwithstanding any independent
testing laboratory or other third party approval
of such component parts or accessory.

Any such action may possibly cause a fire hazard.

Consult local building codes to ensure that you are in
compliance before installing the fireplace.

Fireplaces must be vented to the out-of-doors.

Do not obstruct or modify air inlets/outlets in any
manner.

Do not install combustible materials on any of the
black fireplace surround.

Burn only solid wood fuel or gas logs.

Do not install a solid fuel burning insert or other
products not specified for use with this fireplace.

These fireplaces are not approved for installation in
mobile homes.

Proposition 65 Warning: Fuels used in gas,
woodburning or oil fired appliances, and the products
of combustion of such fuels, contain chemicals known
to the State of California to cause cancer, birth defects
and other reproductive harm.
California Health & Safety Code Sec. 25249.6

Drafts

The fireplace should not be located in areas that create
drafts (ie: frequently opened doors and central heating
air inlets/outlets) that hamper the normal flow of air into
the fire.

Gas Logs

If you plan to install a gas log, the gas line should be
installed before framing the fireplace. The gas line must
be installed by a certified gas line installer.

SR36A / SR42A
SC36A / SC42A

Listed

UL / ULc127

Standard for Factory Built Fireplaces

Safety Information . . . . . . . . . . . . . . . . . .  2

Specifications and Framing . . . . . . . . . . .  3

Parts Identification . . . . . . . . . . . . . . . . . .  5

Chimney Requirements . . . . . . . . . . . . . .  6

Planning Information . . . . . . . . . . . . . . . .  7

Installation . . . . . . . . . . . . . . . . . . . . . . . .  8

Replacement Parts . . . . . . . . . . . . . . . .  19

Accessories . . . . . . . . . . . . . . . . . . . . . .  20

Table of Contents

Содержание Sovereign SC36A

Страница 1: ...0123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 12345678901234567890123456789012123456 123456789012345678901234...

Страница 2: ...use of any component part not manufactured or approved by CFM Spe cialty Home Products in combination or assembly with a Majestic Fireplaces fireplace system notwithstanding any independent testing la...

Страница 3: ...111mm 14 372mm 15 391mm 11 279mm 39 1006mm 3 76mm 8 203mm 7 191mm Outside Air Gas Line Access 1041mm Electrical Access 8 Dia 203mm 3 4 8 7 6 m m FP589 SR36A Series Woodburning Fireplace Fig 1 SR36A Se...

Страница 4: ...trical Access 8 Dia 203mm 3 6 9 1 4 m m FP592 Fig 4 SC42A Series specifications and framing SC42A Series Woodburning Fireplace Circulating Model SR42A Series Woodburning Fireplace Fig 3 SR42A Series s...

Страница 5: ...Fig 5 Fireplace and chase parts identification Termination Cap Storm Collar Pan Flashing Draftstop Batt Insulation cut out around fiestop Firestop Ceiling Level Nailing Flange Gas Line Access both sid...

Страница 6: ...ey exit SR SC36A SR SC42A Maximum 90 0 90 0 Minimum Without Elbows 12 6 12 6 With 2 Elbows 14 6 14 6 With 4 Elbows 21 0 21 0 B Do not use more than 4 elbows per chimney Attach the straps of the return...

Страница 7: ...horizontal distance from the chimney to the peak of the roof is 10 3m or less the top of the chimney must be at least 2 610mm above the peak of the roof but never less than 3 914mm in height above th...

Страница 8: ...WHEN INSTALLING A FIRE PLACE IN AN INSULATED ENCLOSURE BE SURE ALL REQUIRED AIR SPACES ARE MAINTAINED Page 14 Fig 20 Installation Chimney Supports The chimney system is supported by the fireplace for...

Страница 9: ...clamps Feed electrical wire through listed cable clamp leaving approximately six 6 inches of wire exposed through the EB1 Secure listed cable clamp to the wire Attach white wire from power source to o...

Страница 10: ...er point of the chimney on ceiling as though a straight up chimney arrangement is to be used Measure your offset dimension from straight up chimney center point on ceiling Ceiling Chimney Hole Possibl...

Страница 11: ...st chimney section to the collar on top of the fireplace Install the pipe as pictured in Figure 16 When you get a good lock you will hear the pipe clearly snap together Once sections are snap locked i...

Страница 12: ...on the ceiling side and the angled portion extending up into the hole If the area above the ceiling is an attic position the firestop spacer with the flange on the top of the framed hole and the angle...

Страница 13: ...ng centerpoint of the flue system Drive a nail up through roof at the center point This will determine center point on outside of the roof Cut and Frame Roof Hole Size of roof hole varies with the typ...

Страница 14: ...ing for radiant models and 12 305mm from top of grille opening for circulating models Do not install a mantel face plate less than 6 159mm from top of fireplace opening for radiant models and 6 159mm...

Страница 15: ...6 159mm Min 12 305mm Max 12 305mm Min 1 38mm 6 159mm Min Mantel Clearance Radiant Model No Noncombustible Facing Material Combustible Mantel and Trim Finished Wall Header Standoff Noncombustible Mater...

Страница 16: ...overlap minimum May install noncombustible decorative covering OR 018 min sheet metal FIREPLACE HEARTH COMBUSTIBLE FLOOR MINIMUM INSULATION VALUE R 4 MIN FIREBOX OPENING A Min clearance to combustible...

Страница 17: ...a given thickness T K thermal conductivity Noncombustible material with a lower R value may be used provided thickness of material is sufficiently greater to maintain an equivalent total thermal resi...

Страница 18: ...TE When installing an ANSI Z21 11 2 ventless appliance the finishing material used for the mantel must be rated at 250 F or greater BTU input of a gas appliance installed in fireplace should be rated...

Страница 19: ...fireplace 20005487 20005631 5 Screen Pulls 5584139 5584139 6a Firebrick Hearth 20005621 20005421 6b Firebrick Rear 20005627 20005462 6c Firebrick Right Side 20005626 20005461 6d Firebrick Left Side 2...

Страница 20: ...e coverage provided by the owner s insur ance Glass Door Standard Bi Fold door set Brushed Brass finish 36GDKBBSR SR SC36A 42GDKBBSR SR SC42A Black finish 36GDKBKSR SR SC36A 42GDKBKSR SR SC42A Polishe...

Страница 21: ...e chimney through CT100 a chase top Appropriate adapter required Flashing not included Adapter Kit Unites Square Chase Termination with chimney CTSK pipe required Chase Top Housing Low profile pyramid...

Страница 22: ...lation Shield Used to prevent insulation from coming in AIS SK contact with the chimney system SK8 Chimney Sections Used to build chimney systems exposed above SK818CAN 1 Long roof SK84CAN 4 Long 45 C...

Страница 23: ...bject to the following conditions and limita tions 1 This warranty is extended only to a Fireplace installed in the continental United States the state of Alaska and Canada only if and so long as the...

Страница 24: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...

Отзывы: