Troubleshooting 

FP396

Gas Supply On

• Supply Line Hooked up

• Shutoff Valve Open

NO

NO

NO

NO

• Lockout has engaged. Wait 60

   seconds and try again.

• Piezo not tight enough for good

   ground.

• For spark at electrode while 

   depressing Piezo (Red Button)

   1/8" gap to pilot hood needed.

• All wiring connections

• Replace Piezo Ignitor

• Thermodisk

• For Air in the lines

• Thermopile needs a minimum

   325mV. Adjust pilot flame height.

• All wiring connections

• Replace Thermopile

• Thermocouple needs a minimum

   of 14mV.

• Defective valve. Turn to pilot, 

   meter should read greater than

   100mV.

• Thermodisk

Pilot Lights with

Piezo Ignitor

YES

YES

YES

YES

Pilot Stays Lit

Pilot Lights Main

Burner

System OK

START

CHECK

•  Wall switch is not turned on. 

   Watch for grounded wires!

• Thermopile needs a minimum

   325mV

• Plugged burner orifice

FP396

NVC-standing pilot troubleshooting

5/6/98

Nova SIT 820 Standing Pilot

Содержание NVBC36EN

Страница 1: ...s supplier Do not store or use gasoline or other amma ble vapors and liquids in the vicinity of this or any other appliance FOR YOUR SAFETY If you smell gas 1 Open windows 2 Do not touch electrical sw...

Страница 2: ...es 6 Mantels 6 Mantel Chart 6 Hearth 6 Insulating for Cold Climates 6 Framing Finishing 7 Final Finishing 7 Gas Speci cations 7 Gas Inlet Manifold Pressures 7 High Elevations 7 Parts Identi cation and...

Страница 3: ...Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appli ance must be installed on a metal or wood panel extending the full width and...

Страница 4: ...521mm 559mm Recessed Nailing Flange 6 DIA Rough Opening Width 41 Rough Opening Depth 3 76mm 1041mm FP562 Fig 2 NVBC36 Series speci cation and framing dimensions NVBC36 Series Gas Appliance Circulatin...

Страница 5: ...1mm Recessed Nailing Flange 6 DIA Rough Opening Width 47 Rough Opening Depth 3 76mm 35 895mm 1194mm FP564 Fig 4 NVBC42 Series speci cation and framing dimensions NVBC42 Series Gas Appliance Circulatin...

Страница 6: ...b Opening F 14 356 mm K 14 356 mm G 12 305 mm L 12 305 mm H 10 254 mm M 10 254 mm I 8 203 mm N 8 203 mm J 1 38 mm O 1 38 mm Black Sur round Face CFM164 CFM170 Fig 5b Combustible mantel leg minimum ins...

Страница 7: ...000 21 500 NVBC36EN Natural Electronic Ignition 30 000 21 500 NVBR36EP Propane Electronic Ignition 30 000 22 000 NVBC36EP Propane Electronic Ignition 30 000 22 000 NVBR42RN Natural Millivolt Hi Lo 30...

Страница 8: ...ource to the appliance location has not been accomplished install the required pipe Consult local plumbing code to assure proper pipe size The gas pipeline can be brought in through the right side of...

Страница 9: ...ays provide a union so that gas line can be easily disconnected for burner or fan servic ing See gas speci cation for pressure details and ratings NOTE If ex connector is used it must be kept inside o...

Страница 10: ...o position excess wire completely within the EB1 Attach the cov erplate to the replace Fig 11 Fig 11 Junction box EB 1 hook up FP580 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical...

Страница 11: ...le venting configuration Unacceptable venting configuration FP567a Fig 14 Venting con gurations when installing 36GSKBB 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 2 4 6 8 10 12 14 16 18 20 A FP...

Страница 12: ...hree times with a non ammonia household cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on...

Страница 13: ...tment For units equipped with Hi Lo valves ame adjustment is accomplished by rotating the Hi Lo adjustment knob located near the center of the gas control Flame Characteristics It is important to peri...

Страница 14: ...14 NVB Series B Vent Gas Fireplace 7412950 LG151 NVB36 log flames 2 2 01 djt Red Glow Embers LG151 Fig 19 NVB36 ame appearance LG150 NVB42 log flames 2 1 01 djt LG150 Fig 20 NVB42 ame appearance...

Страница 15: ...push in or turn by hand do not try to repair it call a quali ed service technician Applying force or any attempted repair may result in a re or explo sion D Do not use this replace if any part has be...

Страница 16: ...d to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result...

Страница 17: ...tor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple needs a minimum of 14mV Defective valve Turn to pi...

Страница 18: ...to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check electrical connections between module and gas control If okay replace...

Страница 19: ...almost identical to taking care of the Standing Pilot models Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean At least once per year the lo...

Страница 20: ...20003953 5 Ceramic Tile single 57803 57803 6a Burner Ori ce Natural Manifold Ori ce 20003532 20003547 6b Burner Ori ce LP Manifold Ori ce 20003541 20003552 7 Thermodisk 20001558 20001558 8 Remote Swi...

Страница 21: ...E Pilot Assy Natural 4 Way 10002387 10002387 29b E Pilot Assy LP 4 Way 10002388 10002388 30 Sensing Electrodes 57885 57885 31 Ignition Device Honeywell 20000005 20000005 32 Transformer 7522409 7522409...

Страница 22: ...nction box is available for use with the fan kits The EB 1 is standard on the electronic igni tion models Glass Doors Bi fold and single panel glass doors are available to enhance the viewing of the r...

Страница 23: ...ion the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provisions of this w...

Страница 24: ...2695 Meadowvale Blvd Mississauga Ontario Canada L5N 8A3 800 668 5323 www cfmcorp com CFM Corporation...

Отзывы: