GBR Series B-Vent Gas Fireplace

7412955

Operating Instructions

Glass Information

Only glass approved for use in Majestic 
Fireplaces  products may be used for re-
placement.

• 

Glass doors are optional. The 

appliance may be operated safely without glass 
doors.

• 

The use of any non-approved replacement glass will 
void all product warranties.

• 

Bi-fold glass doors MUST BE completely open or 
closed while the appliance is in operation.

• 

Care must be taken to avoid breakage of the glass.

• 

Under no circumstances should this appliance be 
operated with broken  glass. Replacement of the 
glass as supplied by the manufacturer should be 
completed by a licensed qualified service person.

• 

Replacement glass is available through your 
Majestic Fireplaces dealer and should only be 
installed by a licensed qualified service person.

Glass Cleaning

It will be necessary to clean the glass periodically. 
During start-up, condensation, which is normal, forms 
on the inside of the glass and  causes lint, dust and 
other airborne particles to cling to the glass surface. 
Also, initial paint curing may deposit a slight film on 
the glass. It is therefore recommended that the glass 
be cleaned two or three times with a non-ammonia 
household cleaner and warm water (we recommend 
gas fireplace glass cleaner). After that the glass should 
be  cleaned two or three times during each heating 
season depending on the circumstances present.

Clean glass after first two weeks of 
operation.

Log Installation

1. Open glass door (if installed).
2. Remove logs from the packaging. (As with all plastic, 

these bags are not toys and should always be kept 
away from children and infants.)

3. Place rear log on back bracket. Ensure that log is 

firmly positioned and there is no side-to-side move-
ment.

4. Place the front log on the front burner (starting to-

ward the rear of the front burner) and slide it forward 
until the notches lock into place.

5. Place the top logs onto the locator notches. Ensure 

that the logs are secure. (Fig. 12)

Fig. 12

  GBR36  log placement.

LG237

GBR logs

5/21/02   djt

Right 

Crossover Log

Left 

Crossover Log

Back 

Log

Front 

Log

LG237

Ember Material Placement

Separate the ember material into small pieces, roughly 
1/2" in diameter and place on the front burner tube. Do 
not pack down; leave in loose, fluffy condition for most 
realistic ember effect. (Fig. 13)

Fig. 13

  Ember placement.

(Overhead View)

LG238

GBR logs

top vu

ember placement

5/21/02   djt

LG238

Lava Rock

The lava rock provided with this fireplace must be 
placed on the firebox base on either side of the burner 
assembly. 

Under no circumstances should lava rock 
be placed on any part of the burner assem-
bly.

Содержание GBR36 Series

Страница 1: ...life FOR YOUR SAFETY Installation and service must be performed by a quali ed installer service agency or the gas supplier Do not store or use gasoline or other am mable vapors and liquids in the vici...

Страница 2: ...bustibles 5 Mantels 5 Mantel Chart 5 Hearth 5 Framing Finishing 6 Final Finishing 6 Gas Speci cations 6 Gas Inlet Manifold Pressures 6 High Elevations 6 Parts Identi cation and Chase Installation 7 Ga...

Страница 3: ...on air must not be obstructed in any way 11 Whether the appliance is installed directly on carpeting vinyl tile or any combustible material other than wood this appli ance must be installed on a metal...

Страница 4: ...1016mm 36 914mm 3 76mm 1 6 m m 37 953mm 13mm 5 4 1 3 7 2 m m 19 502mm 21 533mm 40 1029mm 7 191mm 6 165mm 7 191mm 7 191mm Outside Air Electrical Access Gas Line Access WFP623 GBR36 2 11 98 Rough Openin...

Страница 5: ...70 DV Builder Front View O N M L K J F G H I Mantel Leg CFM164a Mantel Leg Chart 06 22 01 sta Black Surround Face Side of Combustion Chamber CFM170 CFM164 Hearth Extension A hearth extension in front...

Страница 6: ...struct or modify the air inlet outlet grilles in any manner Finish the wall with the material of your choice Refer to Figures 2a and 2b for speci c clearances when install ing a combustible mantel or...

Страница 7: ...essure equal to or less than 1 2 psig 3 45 kPa The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test...

Страница 8: ...to a conveniently located wall receptacle box 2 Attach wire to switch and install switch into recep tacle box Attach cover plate to switch 3 Connect wiring to gas valve Refer to Figure 6 or 7 dependin...

Страница 9: ...ion excess wire completely within the EB1 Attach the cov erplate to the replace Fig 8 FP580 INSTA VENT FREE EB1 JUNCTION BOX 11 18 97 Outside Electrical Box Front Of Unit Inside Front Of Unit FP580 Fi...

Страница 10: ...ed within the vent system using a maximum of two 45 degree elbows B FP567a Fig 11 Venting con gurations when installing 36GSKBB FP567 Fig 10 Venting con gurations FP567 NVBR NVBC VENTING RUNS 11 12 97...

Страница 11: ...hold cleaner and warm water we recommend gas replace glass cleaner After that the glass should be cleaned two or three times during each heating season depending on the circumstances present Clean gla...

Страница 12: ...on gas valve standing pilot only FP390 LO H I Turn counterclockwise to increase flame height Turn clockwise to lower flame height FP390 FLAME ADJUSTMENT KNOB 11 21 96 Flame Characteristics It is impor...

Страница 13: ...smell all around the heater area for gas Be sure to smell next to the oor because some gas is heavier than air and will settle on the oor WHAT TO DO IF YOU SMELL GAS Do not try to light any replace D...

Страница 14: ...d to push in or turn the gas control knob Never use tools If the knob will not push in or turn by hand do not try to repair it call a quali ed service technician Force or attempting repair may result...

Страница 15: ...eded All wiring connections Replace Piezo Ignitor Thermodisk For Air in the lines Thermopile needs a minimum 325mV Adjust pilot flame height All wiring connections Replace Thermopile Thermocouple need...

Страница 16: ...ight All Wiring connections Replace thermopile Thermocouple needs a minimum 14mV Defective valve Turn to pilot meter should read greater than 100mV If not replace Thermodisk Pilot Lights with Piezo Ig...

Страница 17: ...n cable for signs of melting or buckling Take protective actions to shield cable and boot from excessive temperatures Check for 24VAC across MV MV PV terminals If no voltage replace module Check elect...

Страница 18: ...r shutter should be set to 1 16 open 6 Install manifold to burner tube 7 Reinstall burner tube and retaining bracket Burner ori ce and air shutter conversion complete FC102 Air shutter 7 21 99 djt Bur...

Страница 19: ...ube enters the pilot as sembly Tighten tting if necessary 3 Light the main burner and check for leaks around the new pressure regulator assembly Tighten screws if necessary 4 With the main burner ON c...

Страница 20: ...y a quali ed technician In order to properly clean the burner and pilot assem bly turn off the gas to the unit open the glass door if used remove logs exposing the burner and pilot assembly Clean all...

Страница 21: ...es the right to make changes in design materials speci cations prices and discontinue colors and products at any time without notice GBR36 Ref Description GBR36 1 Log Set Assembly 20005291 1a Back Log...

Страница 22: ...37 17 Door Track 3061104 18 Remote Switch Kit 53875 19 Lava Rock Package 55255 20 Bag of Embers 7060109 21 Valve Cover 3078116 22a Electronic Valve Natural 57884 22b Electronic Valve LP 57883 23a Elec...

Страница 23: ...e appliance model number 2 The serial number 3 A description of the part Should you need additional information beyond what your dealer can furnish contact CFM Specialty Home Products 410 Admiral Blvd...

Страница 24: ...Optional remote control units are available to control different functions of the appliance Model Function s Controlled MRC1 ON OFF MRC2 ON OFF and Temperature MRC3 ON OFF and Temperature control with...

Страница 25: ...25 GBR Series B Vent Gas Fireplace 7412955...

Страница 26: ...26 GBR Series B Vent Gas Fireplace 7412955...

Страница 27: ...f upon inspection the damage is found to be the fault of the manufacturer repairs will be authorized at no charge to the customer parts and or labor Any part and or component replaced under the provis...

Страница 28: ...410 Admiral Blvd Mississauga Ontario Canada L5T 2N6 905 670 7777 www majesticproducts com www vermontcastings com CFM Specialty Home Products...