29
DVB4136 Direct Vent Gas Fireplace
20012322
4. Push in gas control knob slightly and turn clockwise
to “OFF”. Do not force.
5. Close control access panel.
1.
STOP!
Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. Turn the ON/OFF switch to “OFF” position.
4. Open control access panel.
5. Push in gas control knob slightly and turn clockwise
to “OFF”.
10. Push the control knob all the way in and hold. Im-
mediately light the pilot by repeatedly depressing
the piezo spark ignitor until a flame appears. Con-
tinue to hold the control knob in for about one (1)
minute after the pilot is lit. Release knob and it will
pop back up. Pilot should remain lit. If it goes out,
repeat steps 5 through 8.
FOR YOUR SAFETY READ BEFORE LIGHTING
Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the
Fire Department
C. Use only your hand to push in or turn the gas
control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Applying force or any
attempted repair may result in a fire or explosion.
D. Do not use this fireplace if any part has been under
water. Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been under water.
A. This heater has a pilot which must be lit manually.
When lighting the pilot follow these instructions
exactly.
B. BEFORE LIGHTING smell all around the heater
area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will settle
on the floor.
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any fireplace
•
Do not touch any electric switch
•
Do not use any phone in your building
•
Immediately call your gas supplier from a neigh-
bor’s phone.
To Turn Off Gas To Heater
Lighting and Operating Instructions
1. Turn the ON/OFF switch to Off position.
2. Turn off all electric power to the fireplace if service
is to be performed.
3. Open control access panel.
Lighting Instructions
6. Wait five (5) minutes to clear out any gas. Then
smell for gas, including near the floor. If you smell
gas, STOP! Follow “B” in the safety information
above. If you do not smell gas, go to the next step.
7. Remove glass door before lighting pilot. (See Glass
Frame Removal section).
8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise
to “PILOT”.
• If knob does not pop up when released, stop and
immediately call your service technician or gas sup-
plier.
• If after several tries, the pilot will not stay lit, turn
the gas control knob to “OFF” and call your service
technician or gas supplier.
11.Replace glass door.
12.Turn gas control knob to “ON” position.
13.Turn the ON/OFF switch to “ON” position or set ther-
mostat to desired setting.
14.Turn on all electrical power to the fireplace.
WARNING:If you do not follow these instructions exactly, a fire or explosion
may result causing property damage, personal injury or loss of life.
SIT NOVA
Honeywell
PILOT
ON
OFF
ON
PILOT
O
FF
OFF
FP1067
lighting instruction
knobs
3/9/01 djt
5
4
3
2
1
OF
F
Pi
lot
3/8" - 1/2"
FP1068
Lighting instructions
Pilots
For Fireplaces Equipped with the SIT 820 Valve
Содержание DVB4136