S12800 Routing Switch Installa
tion Manual V1.0
Maipu Confidential & Proprietary Information
Page 75
If the fault still cannot be located by the preceding steps, please contact the agent or local
technical service engineers.
5.4 Troubleshooting of MPU Card
S12800 routing switch supports two MPU card (control card) slots. If two MPU cards are
inserted, one is active and the other is standby. In the normal working state, the SYS indicator
on the MPU card panel is in the flashing state. If the SYS indicator is off or on, it indicates that
the MPU card is faulty. Please refer to the following steps for troubleshooting.
Step 1:
Check whether the power module works normally. For details, refer to
Troubleshooting about Power Fault
.
Step 2:
Check whether the MPU card is installed well. You can pull out the MPU card and
insert in again to ensure that the MPU card is installed well. After the MPU card
is started, view whether the SYS indicator of the MPU card flashes.
Step 3:
Insert the MPU card to another MPU card slot and view whether the working
state is normal. If yes, it indicates that the previous MPU card slot may be
damaged.
Step 4:
Connect the Console port and view the boot information to locate the fault via
the configuration terminal.
If the fault still cannot be located by the preceding steps, please contact the agent or local
technical service engineers.
5.5 Troubleshooting of SFU Card
SM12800-12-MF (V1) needs to be configured with the SFU card. In SM12800-12-MF (V1), the
SFU card is inserted vertically and each fan module corresponds to one SFU card indicator. In
the normal state, the SFU card flashes (it indicates that the SFU card of the fan card is loaded
successfully and is the normal working state). If the SFU indicator changes to red or off, it
indicates that the SFU card of the fan card is loaded abnormally or the card fails. The following
takes SM12800-12-MF (V1) as an example to describe. Refer to the following steps for
troubleshooting.
Step 1:
Ensure that the MPU card works normally. For details, refer to
.
Step 2:
Confirm that the output power of the power module is sufficient.
Step 3:
Check whether the SFU card is installed well. You can pull out the SFU card and
insert in again to ensure that the SFU card is installed well.
Step 4:
If there is idle SFU card slot on the switch, you can insert the SFU card to the
idle slot and view whether the working status is normal. If yes, it indicates that
the SFU card slot may be damaged.