Digital programmable belt controller

Turn on the controller:

1. Release the safety button  [4], by turning it to the right..

2. Switch the main switch [5] in the upper posiotion, the permit button LED blinks,

at the same time circuit of the lamp 2 is turned on. 

Press the button number [1], the LED lights up. In this mode, the first belt works automatically with the use of photocells.

To start the conveyor belt for the first time overshadow the photocell with any object or press the foot pedal.

If during the work the photocell is obscured by any object, the conveyor stops automatically and it will start again after removing

the object from the photocell line-of-sight contact.

In case of shaded photocell (or in case of lack of signal from it), it is possible to move the conveyor using the footswitch.

If the conveyor belt is running empty for about 12 seconds and nothing will overshadow the photocell, the controller will stop it automatically.

The second belt works automatically and moves according to the first belt, but its operating time is extended for about 2 seconds.

Turn on a conveyor belt in automatic mode:

Controller MV4K - handling

S. START

POWER

POWER

SERVICE

 

Mv4k

O

T P

S

CTRL

OUT 

2

Digital programmable belt controller

S. START

POWER

POWER

SERVICE

 

Mv4k

O

T P

S

CTRL

OUT 

2

Digital programmable belt controller

MAINS S.C.  E.M.Wosińscy  Brzeziny 95-060 ul. Słowackiego 12, tel/fax: 48 46 8752 777 www.mains.pl; [email protected]  

controller: Mv4k

12

Handling

Содержание MV4k/1

Страница 1: ...CHECKOUT CONTROLLER MV4k 1 MV4k 2...

Страница 2: ...tents 2 Table of contents 2 General informatios 3 Pre instalation informations 4 Dimensions 5 6 Terms of use 7 Electrical parameters 8 Controller connections 9 10 Description of the panel 11 Controlle...

Страница 3: ...ht interference The controller is fed in set controller photocell and a set of connectors to connect the cabling Basic parameters automatic control of main belt automatic control of additional belt ve...

Страница 4: ...The lighting lamps of the station should be out of reach of the operator The controller as a machine component and the supply terminals of the controller are not adapted and are not used to connect t...

Страница 5: ...S owackiego 12 tel fax 48 46 8752 777 www mains pl mains mains pl controller Mv4k 5 Mounting dimensions of controller Mounting dimensions of controller ventilation min 15 cm2 20 crevice min 20mm opti...

Страница 6: ...MAINS S C E M Wosi scy Brzeziny 95 060 ul S owackiego 12 tel fax 48 46 8752 777 www mains pl mains mains pl controller Mv4k 6 Mounting photocells Mounting dimrnsions of photocells...

Страница 7: ...50 60Hz with the protective ground Connecting only with the PE guard wire 220 240V 50Hz PE S START POWER SERVICE Mv4k Digital programmable belt controller OP ST CTRL OUT 2 Be careful with the water Th...

Страница 8: ...Output current of the main belt max 2 A Output current of the additional belt max 2 A Max Power consumption of an additional circuit L1 100W Max Power consumption of an additional circuit L2 100W Pow...

Страница 9: ...condenser phase cable of the motor power supply PE protective cable of the motor N neutral cable of the motor power supply 4 Power supply of the motor II X4 LM phase cable of the motor power supply CM...

Страница 10: ...kets The individual cable cores should be insulated tinned or crimped with the use of the end sleeve as shown It is a protection against accidental short circuit of the cores and possible damage of th...

Страница 11: ...rst pressing continuous signal second pressing intermittent signal 4 Safety switch disconnects the power supply terminal phase STOP in case of any emergency you must press the button This will immedia...

Страница 12: ...n after removing the object from the photocell line of sight contact In case of shaded photocell or in case of lack of signal from it it is possible to move the conveyor using the footswitch If the co...

Страница 13: ...ontinuously The second pressing causes the lamp to glow intermittently The third press turns off the lamp circuit Blinking function can be started programmatically and then switching is typical on off...

Страница 14: ...ill be turn off too This is indicated by an intermittent tone and flashing of the SERVICE LED on the front cover One should then use the safety switch STOP 4 or turn the controller off the power with...

Страница 15: ...the service mode 2 is possibility to switch off the pulse lamp mode by pressing the button 3 OUT diode starts flashing it means the lamp is in the constant mode By pressing second time the same butto...

Страница 16: ...g time none of diode lights S START SERVICE CTRL OUT 2 Programming the opering modes MV4 Controller MV4K programing functions Service mode 3 and 4 Service mode 3 Service mode 3 is switched on while be...

Страница 17: ...light ensure proper lighting conditions check whether the CTRL LED switches on after the unveiling the photocell if not call the customer service b The conveyor belt is not in a controlled footswitch...

Страница 18: ...ring the transport the guarantor obligates himself to deliver fixed unit to the advertiser and is responsible for its loss during the transport 7 During the warranty period defective unit will be repa...

Отзывы: