FloodStop 

by 

OnSite 

PRO" 

Leak Detection & Automatic 

Water Shut-off System 
Water Heater Kit - FS3/4NPT  FS1 /2NPT 

Installation and 

Operating 

Manual 

FS1/4C  FS3/8C  FS1NPT  FS1.25NPT 

c@us 

LISTED

Flood Stop Water Heater Kit 

FloodStop 

by 

On Site PRO� 

Congratulations on your purchase of a FloodStop by OnSite PRO� 

electronic water leak detection and automatic water shut-off kit for 

water heaters. This product has been designed to give you years of 

Q 2012 OnSite PRO Inc. 

reliable service and minimize home water damage by detecting water leaks and 

automatically shutting off the water supply. 

To ensure proper installation and to maximize the performance of your 

FloodStop water leak detection system, please read this manual 

thoroughly. 

PLEASE READ CAREFULLY BEFORE PROCEEDING: 

If a leak is detected, the Flood Stop Valve will shut off the water going to the 

water heater. This will stop the continuous flow of water from the water supply 

to the water heater. However, all or some of the water that is already in the water 

heater may still leak out onto the floor. 

NOTE: This unit was shipped with an installation and operating manual that 

contains important information about its operation. If you are 

installing this unit for use by others, we recommend you leave this manual - or a 

copy of it - with the user. 

Water Heater Kit- Model FS3/4NPT 

FEATURES: 

Control Panel has easy to read, lighted function buttons 

AC Power with battery backup - For continued operation in the 

event 

of power outages 

Solid brass, full port motorized ball valve for dependable, long 

lasting performance 

Valve automatically shuts off the water supply when a leak is detected 

Automatic monthly maintenance cycling of the valve to ensure reliable operation 

Valve can be opened and closed with the touch of a button 

Activates an audible alarm when a leak is detected 

Mute button to silence the audible alarm 

Can be reset and reused continuously with the touch of a button 

9.  Plug the pin on the end of the AC Adaptor cord into the 

bottom of the Control Panel, and then plug AC Adaptor 

into a wall outlet. Green Indicator lights will start to 

flash, showing you have power. Note that a red low 

battery indicator light will also flash about every 30 

seconds, and the unit will beep once a minute until the 

batteries are installed. 

NOTE: If a nearby wall outlet is not available you will need to 

purchase a thin low voltage FloodStop"AC Adaptor 

Extension Wire"  Model# WAE-09 (available where you 

purchased your FloodStop System). This wire extends the 

length of the AC Adaptor cord. 

CAUTION: Do not plug the AC Adaptor Into an 

extension cord. 

9. 

10. 

10.  Flood Stop has a battery backup system that allows 

the unit to continue working in the event that you 

have a power outage. To set up the backup system, 

open the front of the Control Panel and install 4 fresh 

AA alkaline batteries (batteries not included). The low 

battery indicator light will now stop flashing and the 

beep will stop. 

-

CAUTION: Replace batteries once a year or sooner as 

necessary. If batteries need to be changed sooner, a red low 

battery indicator light will flash and a beep will sound. 

� 

,.. 

-

;� 

[) 

); 

-

Installation 

11.  Shut off the previously opened faucet and turn on 

both valves that were shut off in steps 1 and 3. 

Check for leaks. Note that a green status light on the 

Control Panel will indicate whether the Flood Stop 

Valve is open or closed. 

How to Operate your Control Panel 

1.  Top button opens Flood Stop Valve 

2.  Middle button closes FloodStop Valve 

3.  Bottom button mutes the audible alarm that 

sounds when a leak is detected 

Testing Your FloodStop System 

1.  Push the Open button to make sure Flood Stop Valve is open. 

• When the FloodStopValve is opening or closing, you will hear the valve motor operating for a 

few seconds. 

2.  Saturate a rag with water and squeeze over Leak Sensor, or dip the Leak Sensor into a small bucket of 

water. Once the Leak Sensor is wet, it will signal the Flood Stop Valve to close, then an audible alarm will 

sound and a red light will flash. 

• Push the Mute button to srlence the alarm, and note that 

the red light will continue to flash. This means 

the Flood Stop Valve is closed, and will remain closed until you push the Open button. 

• Before the Flood Stop Valve can be opened, the Leak Sensor needs to be dry. There is no need to 

unplug the AC Adaptor when drying off the Leak Sensor. 

• The water test can be done with the paper sleeve still on 

the Leak Sensor. Note that the paper sleeve is 

reusable, but once it gets wet you will need to let it air dry flat before placing it back on the Leak Sensor. 

Can be tested at any time with the touch of a button 

Can accommodate additional water leak sensors 

1 Year Limited Warranty 

This Package Contains: 

A  (1) FloodStop Motorized Brass 

Valve (3/4" FIP 

3/4" MIP) 

B  (1) Control Panel 

C  (1)  Leak Sensor with Paper Sleeve 

(l)ACAdaptor 

(l)WireHarness 

F  (1) Hook& Loop Mounting  Pad 

G  (2)  Mounting  Screws with Anchors 

-. 

I..  -

•  0 . 

Ci) 

Check to make sure everything in the package matches the Contents Listing above. 
Read the instructions thoroughly before installing or operating the FloodStop system. 

Warning: Do not put finger(s) inside Flood Stop Valve. Risk of serious injury may occur. 
Caution: Do not grip plastic motor drive for leverage when tightening Flood Stop Valve. 

Preparation 

CAUTION: Make sure the Flood Stop Valve is not connected to the adaptor fitting(s) when soldering. 

WARNING: 

- For use with water only. 

- Do not install on gas line. 

STOP:You may need to purchase additional fittings to install the FloodStop Valve. If you 
are not sure how to install the FloodStop Valve to your existing water line, we recom­
mend that you contact a licensed Plumber. 

Installation

1. Shut off main water supply valve. 

Step 4 instructs you to install the FloodStop Valve 

(3/4" FIP x 3/4" MIP) between the rigid water line 

coming off the manual cold water valve and the wa­

ter heater. Most rigid lines will be copper. Evaluate 

your line and determine which size adapter fitting 

you will need (the most common one will be 3/4. 

solder x 3/4• MIP). Then determine what size union 

you will need between the Flood Stop Valve and the 

water heater. Note that in some cases you can use 

a flexible or corrugated water heater connector in 

place of a union. 

2.  Open faucet nearest water heater to relieve 

water pressure. 

3.  Shut off the manual cold water valve that supplies 

water to the wau�r heater. Note that the top of the 

water heater will usually be marked "Cold" or"lnlet" 

at the point where the cold water line is connected. 

Pressure Drop Data: 

1. 

3. 

The maximum pressure drop for this device 

is 2 psi at a flow rate of 5.5 gpm for NPS-3/4 

and larger. 

Helpful Hints 

If the Leak Sensor Paper Sleeve is misplaced or becomes unusable, a paper towel can be used 

in its place. 

The Leak Sensor has two sets of prongs so you can connect additional Leak Sensors. This is 

helpful when you have the Leak Sensor placed Inside a water heater pan, but also want one 

outside the pan to sense other leaks such as a pressure relief valve failure. You can also link 

them together so they are positioned at different locations around your water heater. 

Once a month, the FloodStop Valve will automatically close and open by itself. The Control 

Panel is programmed to run this cycle to ensure that the valve continues to function properly 

in the event that it needs to shut off the water. 

Hanging Wires may be tied together using twist ties (Not provided). 

Troubleshooting 

Problem 

Status light does not light 

No water comes out of hot side of faucet 

No water comes out of hot or cold side of faucet 

FloodStop Valve does not operate 

Problem 

FloodStop Valve does not operate (continued) 

Leak Sensor becomes wet but Flood Stop Valve 

does not close 

What to Check 

- Make sure there is power to the outlet. 

- Unplug AC Adaptor cord from Control Panel 

and plug back in. 

- If an AC Adaptor extension wire was used, 

unplug both ends and reconnect 

- Make sure fresh batteries are in the Control 

Panel. 

- Push Open button to make sure LeakSmart 

Valve is open. 

- Make sure the manual cold water valve is 

open. 

- Make sure a manual hot water valve was not 

accidentally closed. 

- Make sure main water shut-off valve is

open.

- Make sure both sides of Sensor are dry. 

- Make sure there is power to the outlet. 

- Unplug AC Adaptor cord from Control Panel 

and plug back in. 

What to Check 

- Unplug 6-pin connector from Control Panel 

and plug back in. 

- Locate plug connection between Control 

Panel and FloodStop Valve. Unplug the 

connection and reconnect, making sure 

arrows on side of plugs line up. 

- If an AC Adaptor extension wire was used, 

unplug both ends and reconnect. 

- Make sure fresh batteries are in the Control 

Panel. 

- Unplug long Hat wire from Leak Sensor 

and reconnect. 

- Make sure there is power to the outlet. 

- Unplug AC Adaptor cord from Control Panel 

and plug back in. 

- Unplug 6-pin connector from Control 

Panel and reconnect. 

4.  Position the Flood Stop Valve so that the arrow on the 

side of the valve is pointing to the water heater. Install 

the FloodStop Valve between the rigid water line 

coming from the manual cold water valve and the 

water heater. 

NOTE: The Flood Stop Valve should be installed within 2 

feet of the water heater so that the Leak Sensor can lay 

flat on the floor. 

5.  Mount the Flood Stop Control Panel in an easily 

accessible location within 30 inches of the LeakSmart 

Valve. You may mount the panel using the screws and 

anchors or Hook & Loop Mounting Pad provided. When 

using the Hook & Loop Mounting Pad, make sure the

adhesive is put on a clean, dry surface.

NOTE: Depending on the location you pick, and the distance 

between the Control Panel and the FloodStop Valve, you 

may need to purchase a leakSmart Control Panel to Valve 

Extension Wire, Model# CEXT-09 (available where you 

purchased your Flood Stop System). 

6.  With the contacts of the wire harness connector facing 

you, plug the 6-pin connector end of the Wire Harness 

into the bottom of the Control Panel. 

7.  Take the short round wire coming from the Control 

Panel and plug it into the wire coming from the 

FloodStop Valve. Make sure the arrow on the 

side of each plug lines up with each other. 

NOTE: The Leak Sensor comes with a paper sleeve. If the 

Leak Sensor is going to be placed in a metal water heater 

pan, make sure you leave the paper sleeve on. If the Leak 

Sensor makes contact with metal, it will signal the 

Flood Stop Valve to shut off. The paper sleeve acts as a 

barrier between the Leak Sensor and the metal. When the 

paper sleeve becomes wet, It will signal the Flood Stop Valve 

to shut off. If the Leak Sensor will not be contacting metal, 

you may remove the paper sleeve. 

8.  Connect plug on end of long flat wire coming from 

Control Panel to either set of prongs on the Leak 

Sensor, pushing until plug snaps in place. Then place 

Leak Sensor on the floor next to the water heater, 

preferably on the side that is in line with the floor drain. 

NOTE: Additional Leak Sensors can be connected together 

for added protection.  For additional Leak Sensors, pur­

chase FloodStop Water Leak Sensor, Model# XS-01 (avail­

able where you purchased your Flood Stop System). 

CAUTION: Do not place Leak Sensor or cord in a walk way 

or other location that may cause someone to trip and fall. 

4. 

5. 

6. 

7. 

8. 

Controller  Mounting  Template 

$

27 

(ex  3-�4) 

87mm 

Notice 

• 

0, 

C> 

• Not to be used on Fire Protection Systems

• Four AA batteries must be used as backup

or system will beep continually.

Problem 

What to Check 

Leak Sensor becomes wet but FloodStop Valve 

- Locate plug connection between Control 

does not close (continued) 

Panel and Flood Stop Valve. Unplug the 

connection and reconnect, making sure 

arrows on the side of plugs line up. 

- If an AC Adaptor extension wire was used, 

unplug both ends and reconnect. 

- Make sure fresh batteries are in the Control 

Panel. 

� 

-

Flood Stop Valve closed but now will not open 

- Make sure both sides of Leak Sensor are 

dry. 

The alarm goes off for no apparent reason 

- Leak Sensor is touching metal, or the 

concrete is sweating causing high humidity. 

Correct the problem by placing the Paper 

Sleeve on the Leak Sensor, or use a paper 

towel as a barrier. 

Manual Operation of Flood Stop Valve 

1. Unplug the connection between the Control Panel and the Flood Stop Valve. 
2.  Pull the plastic motor cover off the Flood Stop Valve and slide it down the wire until it stops at the 

plug. Note that no tools are needed to remove the cover. 

3.  Use a mark1H and draw a line across the top of the plastic motor housing. This way once the motor 

is removed you will know how to reposition It for assembly. 

4.  Remove the 4 screws using a Phillips head screwdriver. 

5.  Place thumb and finger on plastic gear and rotate clockwise to open valve or counter clockwise to 

close it. 

This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection 

against harmful interference in a residential installation. This equipment generates, uses and can 

radiate radio frequency energy, and if not installed and used in accordance with the instructions, may 

cause harmful interference to radio communications. However, there is no guarantee that interference 

will not occur in a particular installation. If this equipment does cause harmful interference to radio or 

television reception, which can be determined by turning the equipment off and on, the user is encour­

aged to try to correct the interference by one or more of the following measures: 

• Connect the equipment into an outlet on a circuit different from that to which the receiver 

is connected. 

• Consult the dealer or an experienced radio/TV technician for help. 

Flood Stop Water Heater Kit 

1 Year Limited Warranty 

OnSite PRO Inc. warrants the enclosed Flood Stop product to be free from defects in materials or 

workmanship, under normal use and service, for a period of one (1) year from the date of purchase. 

If at any time during the warranty period the product is determined to be defective, OnSite PRO Inc. 

shall repair or replace it (at our option). The warranty is limited to defective parts as stated. All costs 

of removal and installation of the Flood Stop product, including the replacement of warranty parts, are 

the responsibility of the purchaser. The manufacturer shall not be liable for incidental, consequential, 

or special damages arising at, or in connection with product use 

or 

performance, except as may 

otherwise be accorded by law. Some states do not allow the exclusion limitation of incidental or con­

sequential damages, so the limitation may not apply to you. Any damage to this FloodStop product as 

a result of misuse, abuse, neglect, accident, improper installation, or any use violating the instruction 

manual furnished by us will void this warranty. This warranty does not cover damages or loss caused 

by defects, and the owner's use of the Flood Stop product confirms the understanding that this prod­

uct does not constitute an insurance policy, and is only a loss mitigation product used to reduce the 

risk of water damage. 

To obtain warranty service, call our Customer Service Department at 1-800-667-4833, or e-mail us at 

[email protected]. You may also send the product and original dated receipt, prepaid US post­

age to: On Site PRO Inc 28222 Shadowland Circle, Modjeska Canyon, CA 92676, Attention: Customer 

Service. 

Отзывы: