background image

RESIDENTIAL LIMITED WARRANTY 

FOR CONDENSING BOILERS (CONDENSANDSMARTXS) 

What this Warranty Covers & Who it Applies to: The 

limited warranty provided by Maine Energy Systems 

LLC (

u

MESys") applies only to MESys brand condensing 

boilers with wood pellet burners and accessories 

(

u

Product") sold to you, the first user and purchaser 

provided that the Product was purchased: (1) for your 

normal, household (non-commercial) use, and has only 

been used for normal household purposes; (2) new at 

retail {not a display, "as is", or previously returned 

model) and not for resale, or commercial use; and (3)

within the United States.  Products installed in a

building other than a one or two family residential

dwelling are not covered, under this Warranty unless 

individual Boilers are installed for each dwelling unit. 

Please return your registration card; while not 

necessary to establish warranty coverage, it allows 

MESys to be able notify you in the unlikely event of a 

safety issue. 

How Long this Limited Warranty Lasts: This Limited 

Warranty has two time frames, depending on the 

particular Product component involved. 

(1) MESys warrants that the burner, ignition, electric

and electronic parts, flame tube and burner plate,

chains, bearings, chain pinions, and all other moving

components of the Product are free from defects in

materials and workmanship for a period of 

two (2)

years from the date of initial operation or 

6,000

operating hours, whichever comes first, 

provided they

are installed and properly maintained by a qualified

heating contractor and the other conditions of this

warranty are met, and 

(2) 

In addition, 

all other parts including the boiler 

vessel are warranted to be free from defects in 

materials and workmanship for a period of 

five (5) yeors

from the date of initial operation or 

15,000 

operating

hours, whichever comes first 

provided it is installed and

properly maintained by a qualified heating contractor 

and the other conditions of this warranty are met; and 

Labor is not covered  under this limited warranty. 

The warranty period begins to run upon the date of 

initial operation, and shall not be extended for any 

reason whatsoever.  This limited warranty does not 

cover labor and shipping costs, non-MESYS 

components, serviceable items or normal maintenance, 

nor the other items and events excluded below. 

Terms of Limited Warranty: MESys will provide 

replacement parts for any component that proves to be 

defective in materials or workmanship (excludes labor 

1 of3 

charges) within the periods set forth above, or replace 

it with the most comparable model available from 

MESys at the time of the replacement. The foregoing 

time lines begin to run upon the date of initial 

operation, and shall not be stalled, tolled, extended, or 

suspended, for any reason whatsoever. 

Repair/Replace as Your Exclusive Remedy: During this 

limited warranty period, MESys or one of its authorized 

service providers will provide replacement parts for 

your Product or replace it with the most comparable 

model then available from MESys at the time of the 

replacement (subject to certain limitations stated 

herein,) if your Product proves to have been 

manufactured with a defect in materials or 

workmanship.  All removed parts and components shall 

become the property of MESys at its sole option.  All 

replaced and/or repaired parts shall assume the status 

of the original part for purposes of this warranty and 

this warranty shall not be extended by the replacement 

of such parts.  MESys's sole obligation hereunder is to 

provide replacements for defective Product to a MESys­

authorized service provider during normal business 

hours.  For safety and property damage concerns, 

MESys highly recommends that you do not attempt to 

repair the Product yourself, or use an un-authorized 

servicer;  MESys will have no responsibility or liability for 

repairs or work performed by a non-authorized 

servicer.  If you choose to have someone other than an 

authorized service  provider work on your Product, THIS 

WARRANTY WILL AUTOMATICALLY BECOME NULL AND 

VOID.  Authorized service providers are those persons 

or companies that have been specially trained for 

customer service and technical ability (note that they 

are independent entities and are 

not 

agents, partners, 

affiliates or representatives of MESys). 

Warranty Exclusions: The warranty coverage described 

herein excludes all defects or damage that are not the 

direct fault of MESys, including without limitation, any 

one or more of the following: (a) use of the Product in 

anything other than its normal, customary and 

intended manner (including without limitation, any 

form of commercial use or use that is not for personal, 

family or household purposes);  (b) any party's wilful 

misconduct, negligence, misuse, abuse, accidents, 

improper operation, failure to maintain, improper or 

negligent installation, tampering, failure to follow 

operating instructions, mishandling, unauthorized 

service (including self-performed Hfixing" or exploration 

of the appliance's internal workings); (c) adjustment, 

alteration or modification of any kind;  (d) a failure to 

comply with applicable state, local, city, or county 

electrical, plumbing and/or building codes, regulations 

and laws, including failure to install the product in strict 

Содержание PELLEMATIC SmartXS

Страница 1: ...o installing and servicing SAVE THESE INSTRUCTIONS Operating Manual Pellet heating with auger delivery or vacuum suction system for the end user PELLEMATIC SmartXS FA V2 09 Pelletronic TOUCH USA PE 60...

Страница 2: ...A_FA 2 1 Version valid from 07 2018 Approved Wohlinger Christian Author Manufacturer MAINE ENERGY SYSTEMS LLC 8 Airport Road P O Box 547 Bethel Maine 04217 E Mail info maineenergysystems com MAINE ENE...

Страница 3: ...8 1 Function description 20 8 2 Pellet suction system 22 8 2 1 Assembly of the vacuum system 22 8 3 Storage systems 25 8 3 1 Pellet storage room 25 8 3 2 Flexilo fabric tank 25 9 Operating the Pellema...

Страница 4: ...ral 58 20 1 Chimney 59 20 2 Favorite 59 20 3 Local Settings 60 20 4 Malfunction 61 20 5 Information 61 20 6 ModBUS 62 20 7 E Mail 63 20 8 IP Config 64 21 Software 67 22 Maintenance and servicing 68 22...

Страница 5: ...afe place for future reference Installation and first startup must be carried out by a qualified installer certified by Maine Energy Systems The installation must comply with the requirements of the A...

Страница 6: ...g systems and hot water supply for buildings It is not permissible to use the pellet boiler for any other purpose Reasonable foreseeable inadvertent uses for the pellet boiler are not known The boiler...

Страница 7: ...dures to be followed The boiler correctly starts itself when required by building load There are no user adjustments required for the air controls on your Smart XS It is important to have your Smart X...

Страница 8: ...ppliance and chimney connector joints an uncontrollable burn or excessive temperature indicates excessive draft The efficiency of your Smart XS in condensing mode running at full power is 96 This is t...

Страница 9: ...d lead to death or life threatning injury Warning indicates a situation that could lead life threatning or serious injury Caution indicates a situation that could lead to injury Note indicates a situa...

Страница 10: ...enings in the combustion air inlet must never be partially or completely closed Ventilation systems central vacuum cleaning systems extractor fans air conditioning systems flue gas blowers dryers fuel...

Страница 11: ...stion R Ri is sk k o of f c cu ut t i in nj ju ur ri ie es s d du ue e t to o s sh ha ar rp p e ed dg ge es s Use gloves for performing all work on the boiler D Da am ma ag ge e t to o p pr ro op pe e...

Страница 12: ...ance with the manufacturer s installation specifications or if lacking manufacturers specifications the appliance in question is installed in a manner commonly recognized as safe and correct for the a...

Страница 13: ...le e e es sc ca ap pe e o of f f fl lu ue e g ga as s Do not connect this unit to a chimney flue serving an other appliance unless multiple appliances into a single flue is authorized by all authorit...

Страница 14: ...g upon the boiler room air as supplied by the air inlet and outlet openings for ventilation in the installation room b Independently of the room air via a separate air intake line with a direct connec...

Страница 15: ...and sealed to prevent the escape of condensation Installation without barometric control draft controller is advised Chimney diameter 5 inch And in accordance with chim ney calculation method EN 1338...

Страница 16: ...s clogging of the waste water pipe Dismantle all the parts of the waste water line clean and assemble again Information to help interpret the above information Temperature Class T400 are rated for 500...

Страница 17: ...of the boiler with no valves between the relief valve and boiler Low Water Detection The Low Water Detection device is connected to the Emergency Stop of the boiler Should a low water condition be det...

Страница 18: ...per EN ISO 17225 2 class A1 Ash content max 0 7 Length max 40 mm Diameter 6 mm Fine material max 1 Contents 100 natural wood T Th he e h he ea at ti in ng g s sy ys st te em m i is s s su ui it ta ab...

Страница 19: ...pellet storage rooms and warning signs 4 Legislation in your country must be observed regarding building specifications for storage rooms 5 koFEN also offers FleXILO fabric tanks for storing pellets 7...

Страница 20: ...controlled by means of the flue gas fan After rising up in the flame tube the combustion gases are passed down through the heat exchanger and via the flue gastube and the chimney into the atmosphere T...

Страница 21: ...ine 13 Ash bin 2 Supply and Return 8 Delivery auger 14 Drain valve 3 Air hose 9 Flame return gate 15 Optional Solar Coil 4 Pellet hose suction system 10 Burner 16 Cleaning system 5 Heat insulation 11...

Страница 22: ...ending radius The hose should be as short as possible and with as few curves as possible Bending radius may never be smaller than 12 inches Vertical Lift Max difference in height 10 feet A difference...

Страница 23: ...ease make sure that you cross the hoses as few times as possible Length of the pellet hose The maximum length for pellets hose and air hose are each 66 feet Assembly Use securing clips and carrying bo...

Страница 24: ...Connection of the pellet and air hose to the suction turbine PE 608 USA_FA 2 1 24 Assembly of the vacuum system...

Страница 25: ...he customer Information and important notes on setting up storage rooms can be found in the MESys plan ning documents and at www oekofen com Information on installing the auger extraction system is in...

Страница 26: ...r 9 1 Description of the control panel The control panel is located in the boiler front cover 1 2 3 1 User control unit Operates the boiler controller and the heating controller 2 Main switch Switches...

Страница 27: ...language date and time at Pelletronic Touch 27 9 2 Setting language date and time at Pelletronic Touch Setting the language The factory setting for the language is German Operating Manual PELLEMATIC...

Страница 28: ...Setting the date Setting the time PE 608 USA_FA 2 1 28 Setting language date and time at Pelletronic Touch...

Страница 29: ...there is a malfunction the correspon ding fault message is displayed at this point instead of the weather icon 6 Favorite 1 adjustable 7 Favorite 2 adjustable 8 Favorite 3 adjustable 10 2 User control...

Страница 30: ...new value was not accepted The original value is f Help function inactive g Confirm h Numeric keyboard used to enter values within the min max range 3 Time and date block a Adjustable time or date b...

Страница 31: ...and their function 31 Note Although a scroll down menu is open the navigation icons menu items and parameters behind are active and by touching them it takes you directly there Operating Manual PELLE...

Страница 32: ...10 3 Main Menu In the Main menu you see all submenus By finger pressure on an icon you reach the respective submenu PE 608 USA_FA 2 1 32 Main Menu...

Страница 33: ...Main Menu 33 Menu navigation of Pelletronic Touch Operating Manual PELLEMATIC SmartXS...

Страница 34: ...s Off The adjusted operating mode of the heating circuits and DHW is inactive The frost protection function is active Auto The adjusted operating mode of the heating circuits and DHW is active The fro...

Страница 35: ...uring Values is in the Main menu Pellematic Heating circuit Domestic hot water Solar Accumulator Return pump Heating Plant In the menu item Allocation you see which heating circuits are allocated to t...

Страница 36: ...larger nearby place Search with the following details Postal code location country Postal code country Location country Afterwoods weather data for the next 3 days are downloaded An icon for the curre...

Страница 37: ...weather data for the next 3 days are downloaded An icon for the current weather is displayed on the opening window Note This feature requires an internet connection Cur temperature Current temperature...

Страница 38: ...eating times according to the Set room temperature Heating The Furnace heats constantly according to the Set room temperature Set back The Furnace heats constantly according to the Set back room tempe...

Страница 39: ...uring values Actual value Set value Inputs sensores Outputs pumps mixer and motors Outside Temperature actual Outside Temperature Boiler Temp actual Boiler Temperature Booster Status Booster On Off Fl...

Страница 40: ...for these hea ting days Mo Th 8 With and you switch between the heating blocks You can deactivate heating days in the heating block and activate in another 4 The heating times for Mo Th are assig ned...

Страница 41: ...en the party function deactivates itself automatically 15 4 Vacation The holiday programme cancels the heating times and heats for the entered period on the set temperature level Vacation is in the Ma...

Страница 42: ...the associa ted flow temperature for a heating circuit Base point adjustable from 68 113 F With the change the of base point you provide a parallel shift of the heating curve H limit heating If the av...

Страница 43: ...time to reach the adjusted roomtemp heating Room thermostat influence If the measured room temperature deviates from the set room temperature the heating controller corrects the flow temperature with...

Страница 44: ...ts the cycling On Off On Off of the heating circuit pump If the Set room temperature room temperature hysteresis is reached the associated pump stops If the Set room temperature is 1 C the pump switch...

Страница 45: ...n the time programme to the desired hot water temperature Outside the time programme the installation heats to Watertemp min On The system heats up the domestic hot water continuously on the Water tem...

Страница 46: ...he accumulator temperature is above the switch on temperature during the set heating times the heating circuit is heated until the switch off temperature is reached Solar pump Heating program only act...

Страница 47: ...1 Measuring values Domestic hot water Measuring values DHW is in the Main menu You see all the Heating circuit corresponding measuring values Actual value Set value Inputs sensores Outputs pumps mixe...

Страница 48: ...Off DHW Return pump inactive Auto Temperature regulation within the time programme If the return temperature sensor of the DHW Return pump reaches the Switch off temperature the pump switches off If t...

Страница 49: ...is in menu DHW Return pump You see all the Heating circuit corresponding measuring values Actual value Set value Inputs sensores Outputs pumps mixer und motors 17 2 Time programme DHW return pump In t...

Страница 50: ...s Solar is in the Main menu Solar has following menu items Measuring values Solar Solar circuit 1 2 Solar energy yield 18 1 Measuring values Solar Measuring values Solar is in the menu Solar It displa...

Страница 51: ...for solar cooling If the temperature in the ACC is higher than the ACC temp Max the solar pump switches off The limit sensor measures the temperature in the ACC The solar circuit pump is switched off...

Страница 52: ...Energy is in the menu Solar Yield measuring of solar energy has following menu items Actual Display of the current solar energy refreshes every 60 sec Yield Day Display of todays solar energy since 0...

Страница 53: ...atic has following items Operating Mode Measuring values Pellematic Permanent operation Locktime Continous run Full power Suctionprobe Filling level Suction turbine 19 1 Measuring values Measuring val...

Страница 54: ...orks the same way like the heating circuit time programme 19 3 Continuous running Continuous running is in the menu Smart XS The burner motor runs in permanent operation and transports pellets to the...

Страница 55: ...burner auger run time is calculated automa tically by the PLC depending on the rated power and the boiler setpoint temperature The burner motor is controlled accordingly You can reduce or increase th...

Страница 56: ...when filling level rerises above the adjusted Minimum weight Note Only displaed if mode is set on Textile tank 19 7 Suction turbine Suction turbine is in the menu Smart XS Set a Time full hours at whi...

Страница 57: ...Cleaning 57 19 8 Cleaning Cleaning is in the menu Smart XS Here you activate the function Cleaning On Off Duration of boiler cleaning in seconds Operating Manual PELLEMATIC SmartXS...

Страница 58: ...ol related settings and individual operating options for the customer General is in the Main menu The menu General includes Chimney Favorit Values Local setting Datalog Malfunction Info Save Load ModB...

Страница 59: ...perature and the rest of the time limit After the expiry of the time limit the function chimney ends time of expiry the operation Chimney sweeper ends The button Cancel ends the function Chimney 20 2...

Страница 60: ...g menu items Language Unit Date Time Choose between the languages German English UK English U S French Spa nish Italian Dutch Danish and Russian You can choose between isometric and imperialist number...

Страница 61: ...y It remains until it is acknowledged The menu remains the fault incident reports as long as they are corrected up 20 5 Information Information is in the menu General In the menu item information are...

Страница 62: ...ote The Modbus registers may be set not less than two hours in cyclic operation otherwise the life span of the operating device can decrease Off TCP Server Defaultport for ModBUS is 502 PE 608 USA_FA...

Страница 63: ...server Only the recipient address needs to be configured To ensure maximal flexibility E mail settings can set individually Port used for sending email depends on provider Select encryption mode speci...

Страница 64: ...equired in the local network GW The gateway enables the touch operating device the access to the internet D1 D2 Server which provide routing information Set DHCP On or Off depending on your network En...

Страница 65: ...spe cial services e g 25 Mail 80 Web and so on The ping prevents the internet connection from beeing closed by the router Therefore a query to the Maine Energy Systems server is started at certain tim...

Страница 66: ...be used But the remote controll of the Touch operating device remains active and can be uses as before via port forwarding DynDns fixed external IP LAN and so on All functions for the network interne...

Страница 67: ...Software 67 21 Software Software is in the Main menu Software shows you the name of the current software Operating Manual PELLEMATIC SmartXS...

Страница 68: ...in a manner inconsistent with operating instructions in the manual Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a noncombusti...

Страница 69: ...ge Ashbox 22 2 Cleaning the boiler every year The pellet boiler is equipped with an automatic cleaning system that cleans the heat exchanger every day In ad dition you need to clean the boiler manuall...

Страница 70: ...witch off the main switch before starting any mainte nance work on the system R Ri is sk k o of f c cu ut t i in nj ju ur ri ie es s d du ue e t to o s sh ha ar rp p e ed dg ge es s Use gloves D Da am...

Страница 71: ...Cleaning the boiler every year 71 Emptying of the ash box also possible during operation Note Acknowledge the error message Ashbox Operating Manual PELLEMATIC SmartXS...

Страница 72: ...Cleaning the boiler the boiler must be switched off before Cleaning the heat exchanger PE 608 USA_FA 2 1 72 Cleaning the boiler every year...

Страница 73: ...Cleaning the boiler every year 73 Cleaning the waste water pipe the boiler must be switched off before Operating Manual PELLEMATIC SmartXS...

Страница 74: ...enance intervals We recommend taking out a maintenance contract with your service technician 22 4 Repairs Only authorised specialists may carry out repair work on this system Use original spare parts...

Страница 75: ...ure that no flammable materials are stored in the boiler room Make sure that no washing is hanging in the boiler room Check the display on the control panel for malfunction messages Check the flue gas...

Страница 76: ...f the heating system before entering Check the level of pellets in the textile tank and order more pellets in good time 22 6 Disposal information Ensure environmentally sound disposal in accordance wi...

Страница 77: ...Pellet boiler cautionary markings 77 23 Pellet boiler cautionary markings Operating Manual PELLEMATIC SmartXS...

Страница 78: ...PE 608 USA_FA 2 1 78 Pellet boiler cautionary markings...

Страница 79: ...Pellet boiler cautionary markings 79 Operating Manual PELLEMATIC SmartXS...

Страница 80: ...e or replace it with the most comparable model available from MESys at the time of the replacement The foregoing timelines begin to run upon the date of initial operation and shall not be stalled toll...

Страница 81: ...ETS OUT YOUR EXCLUSIVE REMEDIES WITH RESPECT TO PRODUCT WHETHER THE CLAIM ARISES IN CONTRACT OR TORT INCLUDING STRICT LIABILITY OR NEGLIGENCE OR OTHERWISE THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANT...

Страница 82: ...uthor Manufacturer MAINE ENERGY SYSTEMS LLC 8 Airport Road P O Box 547 Bethel Maine 04217 E Mail info maineenergysystems com MAINE ENERGY SYSTEMS LLC www maineenergysystems com Subject to modifcations...

Отзывы: