6
6 720 607 090
3. Technical Data
TABLE 1 - GENERAL
TABLE 3 - PERFORMANCE
TABLE 2 - FLUE DETAILS
The appliance has a permanent pilot.
The appliance and flue components are packed in separate
cartons.
The appliance is for use with Natural Gas only.
Maximum cold water supply inlet pressure
12 bar (180 p.s.i.)
Minimum cold water supply inlet pressure to operate the appliance
0.2 bar (2.9 p.s.i.)
Minimum cold water supply inlet pressure for maximum domestic hot water flow
1 bar (15 p.s.i.)
Domestic hot water delivery with temperature control knob fully anticlockwise
4 to 13 litres/minute at
25°C temperature rise
Domestic hot water delivery with temperature control knob fully clockwise
2.5 to 6 litres/minute at
55°C temperature rise
* These values & settings apply when the
appliance has been converted to operate in
conjunction with a Se-duct type flue system.
Natural Gas
Se-duct*
Gas category
I
2H
I
2H
Appliance Type
C
11
C
21
Minimum rated output
7 kW
7 kW
Maximum rated output
23 kW
20.7 kW
Rated input (Net)
25.5 kW
23 kW
Gas rate (CV 34 MJ/m
3
)
2.9 m
3
/hr
2.6 m
3
/hr
Inlet pressure
20 mbar
20 mbar
Number of injectors
16
16
Injector diameter
1.05 mm
1.05 mm
Pilot injector marking
5
11
Burner pressure
14.1 mbar
12.5 mbar
Height
846 mm
846 mm
Width
420 mm
420 mm
Depth
285 mm
285 mm
Dry weight
20 kg
20 kg
Gas connection
15mm Copper 15mm Copper
Hot/cold water connections
15mm Copper 15mm Copper
Wall hole size - width
310 mm (3 in.)
Wall hole size - height
300 mm (3 in.)
min. length
100 mm (4 in.)
max. length
150 mm (6 in.)
min. length
150 mm (6 in.)
max. length
230 mm (9 in.)
min. length
230 mm (9 in.)
max. length
380 mm (15 in.)
min. length
380 mm (15 in.)
max. length
610 mm (24 in.)
Sales Code 31/12968 - Se-duct flue kit
Sales Code 31/10321
Sales Code 31/10322
Sales Code 31/10323
Sales Code 31/10324
Содержание Multipoint BF
Страница 7: ...7 6 720 607 090 4 Dimensions and Fixings Fig 5...
Страница 19: ...19 6 720 607 090 17 Notes...