7.0 Legislation

10

© Baxi Heating UK Ltd 2009

7.1

Installation, Commissioning, Service & Repair

1. This appliance must be install in accordance with the
manufacturer’s instructions and the regulations in force. Read
the instructions fully before installing or using the appliance.

2. In GB, this must be carried out by a competent person as
stated in the Gas Safety (Installation & Use) Regulations.

3. 

Definition of competence:

A person who works for a Gas

Safe registered company and holding current certificates in the
relevant ACS modules, is deemed competent.

4. In IE (Eire), this must be carried out by a competent person
as stated in I.S. 813 “Domestic Gas Installations”.

All Gas Safe registered engineers carry an ID card with their
licence number and a photograph. You can check your
engineer is registered by telephoning 0800 408 5500 or online
at www.GasSafeRegistered.co.uk

The boiler meets the requirements of Statutory Instrument
“The Boiler (Efficiency) Regulations 1993 No 3083” and is
deemed to meet the requirements of Directive 92/42/EEC on
the energy efficiency requirements for new hot water boilers
fired with liquid or gaseous fuels:-

Type test for purpose of Regulation 5 certified by:
Notified Body 0051.

Product/Production certified by:
Notified Bodies 0051 & 0086.

For GB/IE only.

7.2 

Benchmark Commissioning Checklist

1. Please ensure that the installer has fully completed the
Benchmark Checklist on the inside back pages of the
installation instructions supplied with the product and that you
have signed it to say that you have received a full and clear
explanation of its operation. The installer is legally required to
complete a commissioning checklist as a means of complying
with the appropriate Building Regulations (England and Wales).

2. All installations must be notified to Local Area Building
Control either directly or through a Competent Persons
Scheme. A Building Regulations Compliance Certificate will
then be issued to the customer who should, on receipt, write
the Notification Number on the Benchmark Checklist.

3. This product should be serviced regularly to optimise its
safety, efficiency and performance. The service engineer should
complete the relevant Service Record on the Benchmark
Checklist after each service.

4. The Benchmark Checklist may be required in the event of
any warranty work and as supporting documentation relating
to home improvements in the optional documents section of
the Home Information Pack.

Содержание Combi 30 HE

Страница 1: ...Baxi Heating UK Ltd 2009 User s Guide and Important Warranty Information Combi 30 HE Please keep these instructions in a safe place If you move house please hand them over to the next occupier...

Страница 2: ...Heating and Hotwater Industry Council For more information visit www centralheating co uk Baxi Heating UK Ltd 2009 All rights reserved No part of this publication may be reproduced or transmitted in a...

Страница 3: ...illuminate when there is a demand for heat to the boiler Central Heating System Pressure The normal operating water pressure is between 1 and 2 0 bar If the pressure exceeds 3 bar the safety pressure...

Страница 4: ...electricity to the boiler is switched on Reset Power On Indicator Boiler On Indicator Burner On Indicator Boiler operating satisfactorily bar 0 1 2 3 4 Is the Central Heating System Pressure needle in...

Страница 5: ...itted set high enough 15 10 5 20 2 5 15 10 5 20 2 5 Turn Room Thermostat to maximum setting typical example shown If you don t know what you need to do to get the boiler to light or need help with the...

Страница 6: ...operate for 1 minute in every 24 hours to prevent sticking 3 5 Safety Thermostat 1 Your Baxi Combi HE is fitted with an additional safety devices which shut down the boiler in the event of the system...

Страница 7: ...refully open the second tap 6 When the needle on the gauge is indicating 1 or more turn both taps off 7 Disconnect the metal braided hose from the taps a small amount of water may be present and remov...

Страница 8: ...eration 450mm For Servicing NOTE The boiler can be operated with a clearance of 5mm at the right This is also sufficient for routine maintenance However a clearance of 20mm is required if it is necess...

Страница 9: ...system the gas and electricity must be left on and the appliance set in the central heating mode 3 The boiler incorporates an integral pump protection feature which continually monitors the time since...

Страница 10: ...r gaseous fuels Type test for purpose of Regulation 5 certified by Notified Body 0051 Product Production certified by Notified Bodies 0051 0086 For GB IE only 7 2 Benchmark Commissioning Checklist 1 P...

Страница 11: ...t not be used until the fault has been corrected by a competent person Warning Gas Tap Heating Flow and Heating Return Isolating Valves Fig 10 In an Emergency If a water or gas leak occurs or is suspe...

Страница 12: ...er visit or for any general advice that you may need Our contact centre is open Monday to Friday 8am 6pm weekends and Bank Holidays 8 30am 2pm excluding Christmas Day and New Years Day When calling he...

Отзывы: