39
13.0 Servicing
© Baxi Heating UK Ltd 2014
13.2
Annual Servicing - Inspection (Cont)
6. Undo the nut on the gas pipe at the gas/air inlet (Fig. 72)
and the gas valve. Remove the pipe, taking care not to lose
the sealing washers. Also remove the injector.
7. Disconnect the electrode lead caps, remove the strain
relief clip from the sensing lead and disconnect the lead.
Remove the fan electrical plugs and pull the sensing pipe off
the fan.
8. Undo the screw securing the fan air inlet pipe to the
bracket on the boiler top panel. Remove the pipe (Fig. 73).
9. Undo the five retaining nuts and washers and remove the
fan, gas/air inlet and burner assembly (Figs. 74).
10. Carefully clean any debris from the heat exchanger.
11. Inspect the burner, electrode position, insulation, and
gasket, cleaning or replacing if necessary. Clean any dirt or
dust from the air box.
12. Reassemble in reverse order.
DHW Filter
13. If the flow of domestic hot water is diminished, it may
be necessary to clean the filter.
14. Initially check the cold water inlet tap filter.
15. Turn the tap off and draw off from a hot tap. Undo the
blanking cap and remove the threaded bush
(Fig. 75).
16. Extract the filter and rinse thoroughly in clean water.
Reassemble and check the flow. If required clean the
restricter filter as described below.
17. Pull off the Hall Effect sensor. Undo the restricter from
the inlet/return manifold (Fig. 76).
18. Rinse the filter thoroughly in clean water and reassemble
in reverse order.
19. Turn the selector switch fully anticlockwise against the
spring pressure to the reset position and hold for 5 seconds
to reset the boiler.
20. Complete the relevant Service Interval Record section of
the Benchmark Commissioning Checklist at the rear of this
publication and then hand it back to the user.
Cold Water
Inlet Tap
Blanking
Cap
Threaded
Bush
Fig. 75
Hall Effect
Sensor
Hydraulic Inlet
Assembly
Fig. 76
Restricter
Filter
Gas Pipe
Injector
Fan Air Inlet Pipe
Gas/Air Inlet
Fan, Gas/Air Inlet &
Burner Assembly
Fig. 72
Fig. 73
Fig. 74