10.3 Control cable preparations,
network
DANGER
Danger to life from electric
shock.
Switch off the mains fuse at
the fuse box when carrying out
any work on the ventilation
unit’s electrical equipment.
Position a visible warning
notice to avoid the unit being
accidentally switched back on.
See Chapter 10.8 for details of the
electrical connections of the ventilation
unit(s) and room air control(s).
Install recessed-mounted boxes for UP
room air control(s). These should be
supplied by the customer.
Networking example
Lay the control cables, if possible in empty
ducting, to the locations where the
ventilation unit(s) and room air control(s)
are to be installed.
Lay the power cable to the location(s)
where the ventilation unit(s) are to be
installed.
Construction of a network
● Suitable installation locations for room air
control(s) are, for example, central
positions in the room(s) to be ventilated.
Observe the maximum cable length of 50
m for the whole network.
● Up to 9 ventilation units and up to 4 room
air controls of one type can be networked,
● Only original accessories, such as WRG
35-AAD junction boxes,
WRG 35 TAK 5 control cables or WRG 35
TAK 10 should be used.