Operating Instructions MI 24, MI 24h 

 
 
 
 

 

 

31

 

9

 

Additional Reading 

 

Auditory Disorders: A Manual for Clinical Evaluation 

 

 

 

 

 

Jerger, Susan, and James Jerger 

 

 

 

 

 

Boston: College Hill Press, 1981 

 

 

Handbook of Clinical Audiology 

 

 

 

 

 

Katz, Jack 

 

 

 

 

 

Baltimore: William & Wilkins, 1994 

 

 

Roeser´s Audiology Desk Reference 

 

 

 

 

 

Roeser, Ross J. 

 

 

 

 

 

New York / Stuttgart: Thieme, 1996 

 

 

Auditory Diagnosis 

 

 

 

 

 

Silam, Shlomo and Carol A. Silvermann 

 

 

 

 

 

San Diego / London: Singular Publishing Group, 1997 

 

 

Содержание MI 24

Страница 1: ...MAICO Diagnostics 10393 West 70th Street Eden Prairie MN 55344 USA Toll Free 888 941 4201 MI 24 MI 24h Operating Instructions...

Страница 2: ...probe tone MI 24h 17 6 How to measure the Stapedius reflex 18 7 Interpreting test results 23 8 How to test children 26 9 Additional Reading 27 10 Individual setup of the MI 24 28 11 Care and maintena...

Страница 3: ...requirements This user manual should make it as easy as possible for you to become familiar with the functions of the MI 24 The description of the position e g of controls displays and connections fo...

Страница 4: ...mpliance in the middle ear system while the air pressure is varied automatically from a positive value 200 daPa to a negative value 400 daPa max Maximum compliance of the middle ear system occurs when...

Страница 5: ...Operating Instructions MI 24 MI 24h 3 NOTE 1 02 mm H2O 1 0 daPa...

Страница 6: ...ears the reflex is referred to as a contralateral acoustic reflex For best results this reflex measurement is automatically conducted at the air pressure value where the compliance peak occurred duri...

Страница 7: ...eted the inspection notify the MAICO Special Instrument Distributor you purchased this unit from Save all the original packing material and the shipping container so the instrument can be properly pac...

Страница 8: ...Operating Instructions MI 24 MI 24h 6...

Страница 9: ...during transport please wait until it has warmed up to room temperature 3 3 Preparing the MI 24 for use 3 3 1 Connect probe and accessories Connect the probe cable to socket on the rear of the instru...

Страница 10: ...t 2 L R Switch over left right ear 3 REFLEX Reflex measure off ipsi contra 4 MENU 5 LEFT Left cursor control 6 DOWN Down cursor control 7 RIGHT Right cursor control 8 UP Up cursor control 9 ENTER Ente...

Страница 11: ...Operating Instructions MI 24 MI 24h 9 24...

Страница 12: ...Turn the power switch on The LCD will show the type of instrument and software version for a moment Then the basic measuring figure appears The MI 24 should be switched on about 10 minutes before the...

Страница 13: ...hat probe is blocked in the ear LEAKING indicates that the ear tip does not have a proper seal The boxes below Status show the volume of the ear canal the compliance the pressure at maximum compliance...

Страница 14: ...rted for the 2 ml calibration Put the probe tip in the 2 ml cavity Do this again for the 5 ml volume The MI 24 will automatically change into the tympanometry mode The basic menu for the impedance mea...

Страница 15: ...probe until the green control light goes out indicating the end of the measurement A blue control light indicates that the left ear is selected The system is ready for measurements As soon as you have...

Страница 16: ...ar tip tightly on the probe tip The probe tip should end near the end of the ear tip It should not be inserted more than about 1 mm inside the ear tip or just protrude out of the ear tip see Figure 9...

Страница 17: ...ot be compared directly with other audiometric tests such as sound or speech audiometry which assists in the measurement of hearing Furthermore the impedance measurement is an objective measuring meth...

Страница 18: ...nnected with tube C Less sound is reflected to the microphone when the eardrum is stiff and the eardrum transmits the majority of the sound via the middle ear to the inner ear The highest compliance i...

Страница 19: ...anogram Take hold of the top of the outer ear and pull it back Insert the probe with the ear tip into the auditory canal until the control light of the probe is green indicating the start of the test...

Страница 20: ...s been switched off In the boxes to the right the following test measurements are displayed Ear Volume indicates the volume of the section of the auditory canal between the ear tip and the eardrum in...

Страница 21: ...ly print out what was actually measured The printout in the example above does not show reflex frequencies because only the tympanogram was measured If you have saved two tympanograms for example both...

Страница 22: ...robe tone tympanometry looks very similar to the normal tympanometry mode however the following differences will appear on the screen The scaling is now measured in mmho The pre selected frequency 100...

Страница 23: ...was caused before the highest compliance measurement Simultaneously the stimulus ear is irritated by the sound which causes the contraction of the Stapedius muscle The ipsilateral reflex measurement u...

Страница 24: ...Operating Instructions MI 24 MI 24h 22 measurement It is very important that the patient does not move because a reflex can be registered with a change of compliance of 0 05 ml...

Страница 25: ...selected level in dB Figure 19 80 dB appears The I indicates that an ipsilateral test is selected You can choose between the fixed levels 70 75 80 85 90 95 and 100 dBHL and Auto with a starting level...

Страница 26: ...was detected a Fail is reported and the maximum level is shown You can judge this by watching the real time graph if you have a real Stapedius reflex or only disturbance and artifacts The lower dotte...

Страница 27: ...y In the four boxes marked 1 to 4 the Stapedius response is shown graphically Below each box the test level the test frequency and the type of the test I ipsi C contralateral are shown The test result...

Страница 28: ...at which a reflex had been measured appears below the graph If no reflex was registered Fail is printed on the top of the graph behind the test frequency 0 94 ml 0 81 ml 37 daPa 32 daPa ml 3 2 1 0 60...

Страница 29: ...ws the changes in air pressure and the resulting mobility of the system The compliance is recorded on the vertical axis This mobility is expressed as a change in the volume of the ear canal in ml The...

Страница 30: ...of greater than 150 daPa indicates a referral for medical evaluation A normal tympanogram is shown on the previous page in figure 24 7 3 Abnormal Values It is the purpose of this section to provide s...

Страница 31: ...uce a reduced peak in the presence of severe negative middle ear pressure The ear canal volume is normal and the reflex is either absent or at an elevated level Eustachian tube dysfunction in the abse...

Страница 32: ...o create a probe seal with restless children If the child yawns or cries the instrument will not have stable pressure in the outer auditory canal In addition speaking causes Stapedius muscle reflexes...

Страница 33: ...erger Susan and James Jerger Boston College Hill Press 1981 Handbook of Clinical Audiology Katz Jack Baltimore William Wilkins 1994 Roeser s Audiology Desk Reference Roeser Ross J New York Stuttgart T...

Страница 34: ...u options with the up down left right cursor keys The menu option selected is highlighted on the LCD Setup in Figure 25 Accept the chosen menu option by pressing Enter 10 1 The setup menu Select the m...

Страница 35: ...reen Values can be set between 0 daPa and 200 daPa in steps of 25 daPa Press Limit lo With this option you can set the left limit of the normative box displayed on the tympanogram test screen Values c...

Страница 36: ...Operating Instructions MI 24 MI 24h 34 tympanogram test screen Values can be set between 0 1 ml and 1 0 ml in steps of 0 1 ml To leave the Tympanometry Setup Menu press the Menu button...

Страница 37: ...ion select the sensitivity of the Stapedius reflex detection The Sensitive setting will achieve Pass as test results with very small compliance changes i e 0 03ml The Normal setting is the default set...

Страница 38: ...and restarted with the probe button L R or Pause both the test ear and the test can be selected paused and restarted with the probe button or off Subject Data Printout Turn the printout of the headlin...

Страница 39: ...After selection all the texts appear in the chosen language Display adjust The contrast of the LCD can be changed with this option 10 5 Insert your personal printout data Select the menu option Clini...

Страница 40: ...cleaning To clean the instrument probe contralateral receiver and other accessories use a soft damp cloth use warm soapy water no liquids containing alcohol or ammonia should be used to gently wipe t...

Страница 41: ...because it is only coated on one side If it is inserted wrong no printout will be visible Gently insert the paper end in between the rubber roll and the black plastic part at the rear of the printer F...

Страница 42: ...to return the MI 24 to the Maico Special Instrument Distributor from whom it was purchased or directly to Maico after receiving a return authorization This warranty does not cover breakage or failure...

Страница 43: ...diometer s calibration may be in error perform a biological check on a known ear If all retests show major changes calibration is probably in error All repair and recalibration should be done at an au...

Страница 44: ...instrument in the original shipping carton using the packaging provided Be sure to include all accessories as they are required for proper calibration 2 Enclose an explanatory letter describing the se...

Страница 45: ...tympanometer works properly the instrument has to be checked and calibrated at least once a year The service and calibration must be performed by an authorized service center The use of non calibrate...

Страница 46: ...strument test The test person should be healthy no otitis etc and should not be exposed to loud noise for at least 12 hours before the test The instrument must be calibrated according to chapter 3 5 o...

Страница 47: ...Operating Instructions MI 24 MI 24h 45 Tested by Date...

Страница 48: ...o 105 dBHL High freq option for 4 kHz to 105 dBHL Test level contralat 70 dBHL to 110 dBHL High freq option for 4 kHz to 105 dBHL Attack release time Typical 10 ms ON OFF Ratio Greater than 70 dB Pres...

Страница 49: ...Operating Instructions MI 24 MI 24h 47...

Страница 50: ...option Warm up time less than 10 minutes after power on Environment conditions 15 to 35 C 59 to 95 F operation 5 to 50 C 41 to 122 F storage Maximum humidity 90 storage and operation Dimensions 15 W...

Страница 51: ...e 1 power cable 1 set of ear tips 1 calibration cavities cavities 5ml 2ml 0 5ml 1 printer paper roll for app 350 printouts Consumable 1 roll printer paper Part No 5529 4 pc ear tips yellow 7 mm Part N...

Страница 52: ...Operating Instructions MI 24 MI 24h 50...

Страница 53: ...1162 0321 REV E 07 07...

Отзывы: