4 System and product information
9
For centralised ventilation
, a Centro M / E / H
exhaust air element is installed with an exhaust
air filter and cover → separate Centro operating
instructions.
ER 100 units are approved
for second room
ventilation
. The following control types can be
used for this: Standard, VZ, VZ 15, VZC, G, I, D
or RC. Centralised ventilation with Centro-M / E /
H exhaust air elements is possible in combination
with ER-UP/G housings under certain precondi-
tions (
).
ER 60 units are not permitted for the
second room connection.
For ER radio fans and Maico smart, see 100
RC instructions.
4.4.1 ER-UP housing types
The 3 flush-mounted housing units ER-UP/G, ER-
UPD and ER-UPB are available for flush-mounted
installation. These should be selected to match
the exhaust air system. The connection diameter
for all housing types is DN 75 or DN 80.
4.4.2 Flush-mounted housing ER-UP/G
• Plastic housing without fire protection equip-
ment. Can be combined with ceiling barrier.
• Suitable for wall or ceiling installation, inside or
outside the exhaust air shaft.
• Permissible air outlet direction with wall installa-
tion upwards, to the right or left.
• Plastic exhaust socket with airstream-operated
plastic shutter, maintenance-free.
• For connecting second room ventilation with
knockout points at bottom, on right and left.
4.4.3 Flush-mounted housing ER-UPD
• Can be combined with Saint-Gobain cast duct
PAM-Global RML.
• Can also be used outside fireproof shaft.
• Housing with maintenance-free fire protection
shut-off device to prevent fire transmission
(K90-18017).
• Suitable for wall or ceiling installation, inside or
outside the exhaust air shaft.
• Permissible air outlet direction with wall installa-
tion upwards, to the right or left.
• Metal exhaust socket with airstream-operated
metal backflow preventer with soldered strut.
• For connecting second room ventilation with
knockout points at bottom, on right and left.
4.4.4 Flush-mounted housing ER-UPB
• Housing with maintenance-free fire protection
shut-off device to prevent fire transmission
(K90-18017).
• Housing with fire protection cover for use in fire-
proof exhaust air shafts.
• Suitable for wall or ceiling installation in a fire-
proof exhaust air shaft.
• Permissible air outlet direction with wall installa-
tion upwards, to the right or left.
• Metal exhaust socket with airstream-operated
metal backflow preventer with soldered strut.
4.4.5 Fan insert
• Fan insert with cover and exhaust air filter for
installation in ER-UP/G, ER-UPD or ER-PB
housing.
• Electrical plug connection for quick installation
in the ER-UP housing.
• Fan insert has snap-on attachment for easy in-
stallation.
• Cover with exhaust air filter and time strip. Air
filters are to be changed regularly when filter
change is indicated (time strip).
• Cover can be rotated by ± 5 to compensate for
housings which have been fitted at an angle.
• Filter change without tools.
• For single or second room ventilation using a
single fan. Exception: H models only for single-
room air extraction.
• F and H model: Barrier-free products, as the fan
switches itself on and off automatically.
• Energy-saving motor with thermal overload pro-
tection. This switches itself off in the event of
overheating and then back on again automatic-
ally after cooling down.
• The fans may be subject to jet water in areas 1
and 2 (DIN VDE 0100-701: 2008-10 or
HD 60 364-7:2007).
The
time strip
is visibly attached to a location of
your choice (e.g. next to the cover) and after the
filter change interval has elapsed, it can be dis-
posed of in the domestic waste.
Do not affix the
time strip under the cover
. New time strips are
included in the scope of delivery of the exchange
air filter.
4.4.6 ER-UP controls (circuit board types)
ER-UP fans are available in various models and
with various unit properties. These depend on the
control/circuit board type used in the fan insert.