2. Product information 

│ gb 

 

11 

2.4 Foreseeable cases of misuse 

Maico is not liable for damages caused  
by usage other than its intended purpose. 

The fan unit should not be used: 

●  in single air extraction systems according 

to DIN 18017-3. 

●  close to flammable materials, liquids or 

gases. 

●  to convey chemicals, aggressive gases  

or vapours. 

●  in potentially explosive atmospheres. 
●  outdoors 
●  if there is no protection against accidental 

contact with the impeller on the discharge 
side in accordance with EN ISO 13857. 

 

3. Environmental conditions and 
operating limits 

●  Permissible maximum temperature of air 

 40 °C. 

●  The domestic air supply must be set up so 

that virtually no air can flow into the living 
areas from the kitchen, bathroom and WC. 

●  A room from which the air has to be ex-

tracted must be fitted with a non-closable, 
free supply air cross section of at least  
150 cm²,

e.g. with Maico door ventilation 

grille MLK. 

●  Sufficient supply air intake must be en-

sured during operation with air-ventilated 
fireplaces. The maximum permitted 
pressure difference per living unit is 4 Pa. 

●  VZ, F, KVZ and KF units: Resistance to 

interference according to EN 55014-2 
depending on pulse shape and energy 
component 1000 to 4000 V. If operating 
with fluorescent tubes, extra interference 
suppression measures are needed (L or  
C components or RC modules, protection 
diodes, varistors) because these values 
may be exceeded. 

 

4. Technical data 

See rating plate. 

5. Safety instructions 

 

5.1 General 

● Read these operating instruc-

tions carefully before moun-
ting and commissioning. 

● Assembly and electrical con-

nection may only be under-
taken by trained specialists in 
accordance with Chapter 1. 

● With electrical and equipment 

installation the relevant 
regulations must be observed, 
in Germany particularly DIN 
VDE 0100 with the correspon-
ding parts. 

● Only connect unit to perma-

nently wired electrical instal-
lations with NYM-O or NYM-J 
(2 x 1.5 mm² or 3 x 1.5 mm²) 
cables. Mains isolation device 
required with contact 
openings of at least 3 mm at 
each pole. 

● The fan unit may only be 

operated using the voltage 
and frequency shown on the 
rating plate. 

● Only operate the fan unit 

when it is completely 
installed. 

Содержание ECA 120 SERIES

Страница 1: ...tilator Small Room Fan A rateur pour petits locaux ECA 120 ECA 120 K Montage und Betriebsanleitung Mounting and Operating instructions Instructions de montage et Mode d emploi www m aico ventilatoren...

Страница 2: ...zum Produkt Im Internet unter maico ventilatoren com Mounting an Operating instructions Page 9 Wiring diagrams Page 24 Scope of delivery Small room fan ECA 120 or ECA 120 K Mounting and operating ins...

Страница 3: ...A B C D...

Страница 4: ...den Anweisungen Bewahren Sie diese Anleitung f r einen sp teren Gebrauch gut auf 1 1 Installationspersonal Die Montage ist nur durch Fachkr fte zul ssig Der elektrische Anschluss darf nur von Elektro...

Страница 5: ...hzahlsteuerbar F Ger te k nnen unabh ngig von der Beleuchtung per optionalem Lichtschalter bedient werden Bei Licht an startet die Automatik Wird das Licht ausgeschaltet l uft das Ger t weiter bis die...

Страница 6: ...en Die maximal zul ssige Druckdifferenz pro Wohneinheit betr gt 4 Pa VZ F KVZ und KF Ger te St rfestigkeit nach EN 55014 2 je nach Impulsform und Energieanteil 1000 bis 4000 V Bei Betrieb mit Leuchtst...

Страница 7: ...resultierenden Gefahren verstehen Kinder d rfen nicht mit dem Ger t spielen Reinigung und Benutzer Wartung d rfen nicht von Kindern ohne Beaufsichtigung durchgef hrt werden 6 Montagevorbereitungen 6 1...

Страница 8: ...n Leitungst lle ordnungsgem einf hren 3 Leitungst lle 2 oder 3 vorsichtig aus dem Geh use 4 dr cken herausnehmen und mit einem T llenstecher kreisrund durchsto en F r Aufputzinstallation Leitungst lle...

Страница 9: ...u den Anschluss klemmen alle Versorgungsstrom kreise abschalten Netzsicherung ausschalten gegen Wieder einschalten sichern und ein Warnschild sichtbar anbringen ACHTUNG Ger tebesch digung bei falschem...

Страница 10: ...typen F KF 0101 1255 0000 10 ECA 120 K Thermo Bimetall E180 0913 9100 12 ECA 120 Innengitter ECA 120 K Klappenrahmen 0059 1010 9000 0059 1011 9001 Bei R ckfragen Maico Elektroapparate Fabrik GmbH Stei...

Страница 11: ...instructions safe for use later on 1 1 Installation staff Installation is only permitted when carried out by trained specialists Only qualified electricians are permitted to make the electrical conne...

Страница 12: ...it not speed controllable F units can be operated indepen dently of the lighting using the optional light switch The automatic operating mode commences when Light on If the light is switched off the u...

Страница 13: ...entilated fireplaces The maximum permitted pressure difference per living unit is 4 Pa VZ F KVZ and KF units Resistance to interference according to EN 55014 2 depending on pulse shape and energy comp...

Страница 14: ...y have been instructed about the safe operation of the unit and can understand the resulting risks thereof Children must not play with the unit Cleaning and maintenance must not be carried out by chil...

Страница 15: ...efully press out the cable grommet 2 or 3 from the housing 4 then remove and pierce a round hole in the cable grommet by means of a grommet puncher Use cable grommet 3 for surface installation and cab...

Страница 16: ...hock Prior to access to the connection terminals switch off all supply circuits Switch off main fuses secure against being accidentally switched back on and position a visible warning sign NOTICE Risk...

Страница 17: ...strip E180 0913 9100 12 ECA 120 internal grille ECA 120 K Shutter frame 0059 1010 9000 0059 1011 9001 In the case of questions Maico Elektroapparate Fabrik GmbH Steinbeisstra e 20 78056 Villingen Schw...

Страница 18: ...ilisation du ventilateur Respectez les instruc tions Conservez ces instructions pour une utilisation ult rieure 1 1 Installateurs Le montage est exclusivement r serv des professionnels Le branchement...

Страница 19: ...e et d sactive automatiquement le ventilateur Luminosit de mise en marche sur l appareil au minimum 30 lx luminosit d arr t sur l appareil au maximum 0 3 lx Appareil vitesse non variable Les appareils...

Страница 20: ...de l air l int rieur du logement doit tre r alis e de telle mani re que l air en provenance de la cuisine de la salle de bains et des toilettes ne puisse pas se propager dans les pi ces d habitation...

Страница 21: ...l appareil sont rigoureusement interdites et d gagent le fabricant de toute responsabilit et garantie 5 2 Comportement s r et correct lors du fonction nement Risque de blessure en pr sence d objets d...

Страница 22: ...ine 1 barber les bords de l int rieur de la gaine ATTENTION Risque d endommagement des gaines souples tuyaux agraf s par les crochets ressort Avant le montage dans les gaines souples rompre les mousqu...

Страница 23: ...et les fils non utilis s ATTENTION Risque d endommagement de l appareil par contact avec des composants menac s DES sur platine 5 2 5 3 viter un contact direct des composants ou des surfaces de contac...

Страница 24: ...ctionnement consulter un lectricien qualifi Les r parations sont exclusivement r serv es des lectriciens qualifi s DANGER Danger de mort par lectrocution Avant d acc der aux bornes couper tous les cir...

Страница 25: ...icien sp cialis Chapitre 1 peut se charger du d montage DANGER Danger de mort par lectrocution Avant d acc der aux bornes couper tous les circuits d alimentation lectrique D sactiver le fusible secteu...

Страница 26: ...VZ ECA 120 P ECA 120 24 V ECA 120 KVZ ECA 120 KF ECA 120 F ECA 120 K ECA 120 KP Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Germany Service 49 7720 694 447 technik...

Отзывы: