INSTALLATION INSTRUCTIONS
ECA 100 KF
Version: 2019-05-22 - MAICO VENTILATOREN, www.maico-fans.com - We are not responsible for mistakes or printing errors and retain the
right to make technical modifications without giving prior notice
Page 7
Article
A
B
C
D
ECA 120
115
95
152
24
ECA 150
140
140
178
22.5
1
ECA fan
2
WH wall sleeve
3
AP outside shutter
4
Masonry
5
Plaster
6
Cable entry
Ceiling installation with roof cowl
Please note the following points when fitting ECA 100 ipro, ECA piano, ECA 100, ECA 120 and ECA 150 series model fans
in a ceiling in ventilation systems with a roof cowl:
The minimum distance from the wall must be observed (see wall mounting as well).
Install the wall sleeve or duct.
Surface- or recessed-mounted connecting cable guide.
ECA 100 ipro and ECA piano only available as recessed-mounted fans.
Drain off any condensation present in the duct using a siphon. Fit a T-piece with siphon in the duct (odour seal) for this pur-
pose.
Proper duct insulation reduces the build-up of condensation considerably.
Use a roof cowl with the condensation drain pointing outwards (see recommended accessories).