Installation and operating instructions

Flush-mounted exhaust air elements for Centro centralised
ventilation system according to DIN 18017-3

Centro-M
Centro-E
Centro-H

www.maico-ventilatoren.com

www.maico-ventilatoren.com

Содержание Centro-M

Страница 1: ...Installation and operating instructions Flush mounted exhaust air elements for Centro centralised ventilation system according to DIN 18017 3 Centro M Centro E Centro H www maico ventilatoren com ...

Страница 2: ...es 4 6 Technical data 4 6 1 Environmental conditions and oper ating limits 4 6 2 Regulations for operation with fire places 4 6 3 Technical data table 5 6 4 Storage 5 7 Mounting preparations 5 8 Installation 5 8 1 Installation information on flush mounted housing 5 8 2 Electrical connection 5 8 3 Installation of spiral housing and upper part of housing 5 8 4 Installing the cover 7 9 Commissioning ...

Страница 3: ...late in terior bathrooms toilet rooms and open plan kit chens with exterior windows storage rooms etc After completion of the interior building work the exhaust air elements are inserted into the flush mounted housing units ER UPB ER UPD or ER UP G already installed during the shell con struction phase Exhaust air elements are only intended for do mestic use and similar purposes No other or ad dit...

Страница 4: ...ed housing Shaft level difference according to DIN 4109 tested by IAB Oberursel The Institute for Acoustics and Building Physics in Germany Cover with exhaust air filter and time strip Air filters are to be changed regularly when filter change is indicated time strip Trouble free filter change without tools Centro M with protection class II Installation also permissible with water jets DIN VDE 010...

Страница 5: ...itable dry room Ambient temperature 10 C to 60 C Maico accepts no liability for corrosion damage caused by improper storage e g storage in a damp environment 7 Mounting preparations Suitable mounting material is to be provided by the customer 8 Installation 8 1 Installation information on flush mounted housing The installation of flush mounted housing and the shut off device is described in detail...

Страница 6: ...isk of damage if ESD sensitive com ponents on the board are touched Avoid direct touching of the components or con tact surfaces NOTICE The noise level will increase if the housing floor seal is fitted incorrectly Degree of protection not guaranteed if housing floor seal is positioned incorrectly The housing floor seal must lie flat and without any creases in the housing 7 Check that all screw con...

Страница 7: ...ry first fit a spacing or wall frame 3 With second room extraction insert regulating plate below locking tabs at the side on the in take grille of the cover insert filter mat 4 Lock cover The lock must engage audibly 5 Switch on mains fuse remove warning sign 6 Undertake initial commissioning and function test 7 Affix time strip supplied with the cover and push the activation button A all the way ...

Страница 8: ... reference value during opera tion the newly established reference value is saved The exhaust air element then automatic ally switches back to base load operation or to Off Demand based ventilation automatically or via a switch e g light switch After manual switch on light switch the exhaust air element runs with a start delay of approx 1 minute with demand based ventilation full load After manual...

Страница 9: ... 15 minutes and resets the refer ence value Additional consumers connected to terminal 4 Damage to the unit if connected incorrectly Do not connect addi tional consumers to ter minal 4 The unit may only be connected according to the wiring diagrams Wiring diagrams If the fault persists or reoccurs Disconnect the unit completely from the power supply Let a qualified electrician determine the cause ...

Страница 10: ...Prior to accessing the connection terminals switch off all supply circuits Switch off mains fuse secure against being accidentally switched back on and position a visible warning sign 1 Remove spiral housing 2 Remove all cables 3 Remove lower part of housing from the wall 16 Environmentally responsible disposal The ventilation unit and the packaging contain parts that can be recycled and should no...

Страница 11: ...Notes ...

Страница 12: ...Maico Elektroapparate Fabrik GmbH Steinbeisstr 20 78056 Villingen Schwenningen Deutschland Service 49 7720 6940 info maico de D07 21_EN_DSW AV ...