MAHLE ROU250 Скачать руководство пользователя страница 19

 

 

 

ROU250

en   

|

  19  

|

  Parts Diagram 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание ROU250

Страница 1: ...MAHLE ROU250 EN Operation Manual Recovery Only Unit...

Страница 2: ...Y PERSON WHO OPERATES THIS EQUIPMENT NEEDS TO KNOW AND UNDERSTAND ALL OF THE INFORMATION IN THIS MANUAL FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY OR DEATH READ THIS MANUAL CAREFULLY AND RETAIN F...

Страница 3: ...edure 7 6 2 Purging Procedure 8 6 3 Liquid push pull procedure 8 6 4 Tank Cooling Procedure 9 7 Troubleshooting 10 8 ROU250 System Kits 11 8 1 ROU250 Kit With R134a Manifold Tank 11 8 2 ROU250 Kit wit...

Страница 4: ...all valves are closed This will maximize the lifecycle of the machine as excess moisture from atmosphere will shorten operating life When using an extension cord it should be 14AWG minimum and no long...

Страница 5: ...the recovery unit itself is approved for multiple refrigerants For a complete list of applicable refrigerants please see the specification section of this manual 3 Symbols Use 3 1 Warning notices Warn...

Страница 6: ...quipment and its proper use when servicing motor vehicles and their components Safety information provided with this equipment should be emphasized by the employer and understood by each employee The...

Страница 7: ...f the recovery machine If the recovery machine If the recovery machine fails to start rotate the fails to start rotate the fails to start rotate the fails to start rotate the INPUT valve and the MODE...

Страница 8: ...filling the storage tank once the be used to avoid over filling the storage tank once the be used to avoid over filling the storage tank once the siphon siphon siphon siphon is started it can continu...

Страница 9: ...e hoses as shown 2 Turn the MODE valve to the Recover position 3 Open the Vapor and Liquid valve of the storage tank 4 Power on and start the compressor 5 Open the INPUT valve and OUTPUT valve of the...

Страница 10: ...ressor does not start Machine is in high pressure shutdown Reduce pressure and press High Pressure Switch Output pressure is too high Rotate INPUT valve and MODE valve to PURGE then rotate INPUT valve...

Страница 11: ...ROU250 en 11 System Kits 8 ROU250 System Kits 8 1 ROU250 Kit With R134a Manifold Tank P N 460 80423 00 8 2 ROU250 Kit with R1234yf Manifold Tank P N 460 80424 00...

Страница 12: ...Notes ROU250 ROU250 en 12 System Kits 8 3 R134a Manifold Gauge Set Kit P N 360 83173 00 8 4 R1234yf Manifold Gauge Set Kit P N 360 83174 00...

Страница 13: ...ROU250 en 13 System Kits 8 5 ROU250 Complete Kit R1234yf R134a With Tank P N 460 80425 00...

Страница 14: ...Notes ROU250 ROU250 en 14 System Kits 8 6 Rou250 Unit Only P N 460 80422 00 8 7 Dot Cylinder With Float Switch P N 360 80310 00...

Страница 15: ...ROU250 en 15 Schematics 9 Schematics 9 1 Electrical Schematic...

Страница 16: ...Notes ROU250 ROU250 en 16 Schematics 9 2 Flow Schematic...

Страница 17: ...17 Tube 2 Control Arm 10 Dryer Filter 18 Base 3 Front Panel 11 Hose 19 Rubber Foot 4 Input Gauge 12 Tube 20 Condenser 5 Output 13 Tube 21 Fan 6 Knob 14 Compressor 22 Back Panel 7 Circuit Breaker 15 M...

Страница 18: ...Notes ROU250 en 18 Notes ROU250 en 18 Notes...

Страница 19: ...ROU250 en 19 Parts Diagram...

Страница 20: ...Notes ROU250 035 82540 MAHLE Aftermarket Inc 10 Innovation Drive York PA 17402 U S A Phone 800 468 2321 Fax 717 755 8304 E mail tech mss us mahle com www servicesolutions mahle com...

Отзывы: