Vehicle Data Entry
Pos : 60 /T echnisc he Dokumentation/ Leis tung/F unktion/ Abg as/ 06 LPS Tr akt or/ 0801 LPS Z W-500/BA/I nhalt : 0608 Eingabe der F ahrzeugdat en @ 18\ mod_1254730746752_75. doc x @ 456455 @ @ 1
Vehicle data entry via print menu with <F2> and <ENTER>. Following boxes are available:
•
Make
max. 24 characters, alpha-numeric
•
Model
max. 24 characters, alpha-numeric
•
Operating hours (optional)
max. 24 digits, numeric
•
Customer name
max. 24 characters, alpha-numeric
Setting of vehicle data in Variable 4: see section "Operation / Setting Menu <F1> / Program
Variables".
Use the keypad for data entry.
Confirm with <ENTER> .
Make
--
Pos : 61 /T echnisc he Dokumentation/ Alle G erät e/ 01/Übersc hrift en/Übersc hrift en 1. 1/H /Übersc hrift 1. 1: Haupt menü <F 3> @ 18\ mod_1254731050366_75. doc x @ 456562 @ 2 @ 1
4.4
Main Menu <F3>
Pos : 62 /T echnisc he Dokumentation/ Leis tung/F unktion/ Abg as/ 06 LPS Tr akt or/ 0801 LPS Z W-500/BA/I nhalt : 0608 H aupt menü <F 3> @ 34\ mod_1380094313116_75.doc x @ 1831383 @ @ 1
The following measurement methods can be selected:
Display
Mode
Entry values
•
Constant n
Constant RPM
- Target RPM
•
Constant Md
Constant engine torque
- Target RPM
•
Discrete n
Discrete RPM
measurement
- RPM Start
- RPM Stop
- RPM Step
- Waiting time
•
Warm-up drive
Constant power at
constant RPM and p.t.o
shaft torque
- Warm-up power
With V1.11 or higher, the measurements can
be performed using the engine RPM or the
engine torque. To do this, enter the trans-
mission ratio engine/p.t.o. shaft using <F4>.
0.0 Nm
→
0.0 kW
0 rpm
All display and input values bearing this factor are marked with an asterisk on the display.
First the measurement method [constant n] is
displayed:
Measurement with
constant n <*>
→
Key <+> or <->
Change to a different measurement method
Key <ENTER>
Select desired measurement method