User manual
Structural diagram description
Remote control add/delete instructions:
Turn off the host power,long
Press “disarm” to choose
Press “emergency”
time press “emergency”button
the zone of coding.
to confirm the zone
and powered on.
of coding.
Delete remote control
Add remote control
Long time press “'emergency”
Press “arm” on remote
button. release after hearing a
control,and send address
long 'DI' sound.
code.
3.3 Add/delete detector
Add detector:
1. Long time press 'disarm' button on control panel and
power on at the same time. You will hear a short “DI”
sound then release the “disarm” button, the “ZONE 1”
LED on.
2. Press 'disarm' button again, then choose defense
zone from zone 1 to zone 4, Press 'emergency ' button
to confirm defense zone, zone led flash and detector
triggered for programming
3. After hear a short 'DI' sound, zone led stop flashing,
detector adding finished. If you hear a long 'DI' sound, it
means repeat code or restriction code.
4.After detector finish adding, you can press 'emergency '
button to add the next detector in this zone. Press 'disarm'
button to choose defense zone again. Or power off to quit.
Remarks
: In same defense zone, if this zone already
added 3 detectors, the first detector will be deleted
when the 4th detector added
Delete detector
:
When enter into coding status, press
'disarm' button and confirm the defense zone of the
detector you want to delete, long time press 'emergency'
button. After hear a long 'DI' sound, detector deleted
User manual
Main technical parameter
Detector add/delete instructions:
Turn off the host power,long
Press “disarm” to choose
Press “emergency”
time press “disarm”button
the zone of coding.
to confirm the zone
and powered on.
of coding.
Delete detector
Add detector
Long time press
“
emergency
”
Trigger detector,and send
button. release after hearing a
address code.
long 'DI' sound.
3.4 Recover factory default setting
Press 'emergency ' and 'disarm' button and power on at the
same time. After hear a long 'di' sound, release the buttons
and defense zone led start flashing. Long time press
'emergency “button, release after hear a long 'di' sound, all
LED on, factory default down. Power off and reopen the panel.
(When factory default, all the detectors, remote controls are
deleted)
4: Main technical parameter
4.1 Control panel parameter
1. Working voltage: AC220V±15%;DC12V (8pcs of AA
battery)
2. Operation current: Static
≤15mA; Alarm≤180mA
3. AC output: AC 220V 2A (440W)
4. Alarm time: 300 seconds
5. Receiving frequency: 315MHz
6. Wireless receiving distance: 100-500m (in the open land)
7. Dimension: 212*150*40mm (including antenna)