MAGUIRE LoPro Скачать руководство пользователя страница 6

M A G U I R E   P R O D U C T S ,   I N C .  

 

Rev: January 15, 2019

 

6

L o P r o   R e c e i v e r

 

 
Status Indicator  
 

The LoPro’s status indicator is a green LED located on the front panel of the controller. 

Primarily, this is used to indicate if the unit is powered up, but also serves several other 
purposes. As mentioned earlier, the status indicator is an integral part of setting the LoPro’s 
running mode.  

The status indicator will provide information about the LoPro during standard operation. 

This can be a useful tool for troubleshooting. At any point when the LoPro is turned on, the 
status indicator should be displaying 1 of 4 conditions. The following list describes each, and 
explains what each one means: 

 

  Constantly Illuminated: Satisfied. Not calling for material, presumably hopper full. 

 

  1-Second flash rate: Waiting. Calling for material, but line is currently in use by 

another receiver. 

 

  ¼ Second flash rate: Loading. In the process of conveying material. 

 

  Rapid (1/20

th

 second) flash rate: Alarming. Could be anywhere within the alarm 

routine (see description on page 4).  

 

 
Description of Controls 
 
 

 

 
 

Содержание LoPro

Страница 1: ...MAGUIRE PRODUCTS INC LoProTM Receiver LoPro LoPro LoPro LoProTM TM TM TM Receiver Receiver Receiver Receiver INSTRUCTION MANUAL Copyright Maguire Products Inc 2019...

Страница 2: ...ation ________________________________________ 4 Description of Controls _________________________________________________ 6 Installing the LoPro Receiver ____________________________________________...

Страница 3: ...ossible However technology and product changes may occur more rapidly then the reprinting of this manual Generally modifications made to the pump design or to the operation of the software are may not...

Страница 4: ...ut priority order Adding receivers requires no additional programming sequence or setup Operators simply attach the next receiver s input connector to any other receiver s output connector using a sig...

Страница 5: ...lay is incorporated in between loading cycles Additionally the alarm routine is disabled when set to any of the 4 regrind modes Properly using one of these modes can help to prevent unnecessary vacuum...

Страница 6: ...n about the LoPro during standard operation This can be a useful tool for troubleshooting At any point when the LoPro is turned on the status indicator should be displaying 1 of 4 conditions The follo...

Страница 7: ...ct air pressure to the LoPro fitting Damage or an air leak could result A compressed air filter sold separately is recommended for protection of pneumatic components 4 Connect the 4 pin power signal c...

Страница 8: ...ignal cable and compressed air 3 Release spring latches and remove controller portion 4 Remove replace filter Maguire part ashffd4 Dome side of filter facing toward the material portion 5 When reinsta...

Страница 9: ...Lopro receiver remove the 7 sheetmetal screws holding in the front panel Remove only the front panel Replacement Parts Part Description Maguire Part Number 4 5 dia Dacron filter with foam gasket ashf...

Страница 10: ...as long as equivalent motors with brushes Capable of providing vacuum power for systems up to 1 000 lbs hr Hinged lid for quick cleanout 1 1 2 Vacuum inlet Available in both 120V and 230V models 3rd...

Страница 11: ...M A G U I R E P R O D U C T S I N C Rev January 15 2019 11 L o P r o R e c e i v e r Wiring Diagrams LPR Controller...

Страница 12: ...M A G U I R E P R O D U C T S I N C Rev January 15 2019 12 L o P r o R e c e i v e r MCP Pump...

Страница 13: ...M A G U I R E P R O D U C T S I N C Rev January 15 2019 13 L o P r o R e c e i v e r 3rd Party Pump Control Module...

Страница 14: ...M A G U I R E P R O D U C T S I N C Rev January 15 2019 14 L o P r o R e c e i v e r Dimensional Drawings...

Страница 15: ...M A G U I R E P R O D U C T S I N C Rev January 15 2019 15 L o P r o R e c e i v e r...

Страница 16: ...ssed or implied and of all other obligations or liabilities on our part and MAGUIRE PRODUCTS neither assumes nor authorizes any other persons to assume for it any other liability in connection with th...

Страница 17: ...014 Tel 610 459 4300 Fax 610 459 2700 Email info maguire com Web www maguire com Maguire Europe Tame Park Tamworth Staffordshire B775DY UK Tel 44 1827 265 850 Fax 44 1827 265 855 Email info maguire eu...

Отзывы: