![Magtrol 5211 Скачать руководство пользователя страница 2](http://html2.mh-extra.com/html/magtrol/5211/5211_manual_3646652002.webp)
www.magtrol.com
MANUAL
Page 2 / 4
© 2019 MAGTROL | Due to continual product development, Magtrol reserves the right to modify specifications without forewarning.
5211
1.2
FRONT AND REAR PANEL
Fig.1-1 5211 Front Panel
Fig. 1-2 5211 Rear Panel
2.0 OPERATION
The 5211 is universal for all Magtrol Hysteresis Brakes and Clutches. Due to the wide
range of full scale current requirements, a three position current range control is provided
to improve torque resolution. The full scale current level of the power supply is determined
by the RANGE switch, LOW, MED, and HIGH. Full scale for the ranges are 0.2 A for LOW ,
0.5 A for MED and 1.0 A for HIGH. The digital panel meter indicates the current output level
to within ± 1%.
The included cable has a 2-pin connector on one end and flying leads on the other. The
flying leads can be connected to the brake or clutch leads by way of the supplied wire nuts.
NOTE:
For current ratings on a particular brake or clutch, refer to
Products>Brakes and Clutches at magtrol.com.
All manuals and user guides at all-guides.com