LIGHTING AND OPERATION

 CAUTION:

 Tipping the gas cylinder more than 60 degrees from its upright position may cause torch to flare. The torch has a built-in 

regulator that controls pressure and reduces the risk of pulsating or yellow flames when used other than upright. It is recommended to start 

working with a disposable hand torch cylinder at room temperature and to keep torch upright as much as possible.

1.  To light with a match, hold as shown and open valve (1) slowly. 

2.  To light with spark lighter, open valve (1) slowly before sparking. Hold spark lighter at a 45° angle to the torch opening (3).

NOTE: 

It is very difficult to light with valve fully open.

3.  For hottest, most efficient flame, adjust inner blue flame of MT200C to 1-1/2 to 2 inch length; adjust inner blue flame of 

MT425C to1/2 to 3/4 inch.

4.  If ignition does not occur immediately upon opening the torch valve (1), close the valve and wait 5 minutes before 

attempting to ignite again. Failure to follow this instruction could result in a build up of flammable gas which if ignited could 

result in a fireball that could cause injuries and property damage. Do not open the valve and allow gas to flow through the torch without 

attempting to ignite the torch.

ADDITIONAL NOTE: 

As a safety feature, the burner may snap if the torch is dropped, in which case the burner must be replaced. 

STORAGE

REMOVE CYLINDER FROM TORCH  WHEN NOT IN USE

1.  Make sure valve is closed by turning flame adjustment knob fully clockwise until it stops. Hand-tighten only. Do not force. 

2.  When torch is cool, disconnect cylinder and store torch and cylinder separately and out of reach of children. Observe cautions on 

cylinder label.

3.  Do not expose cylinders to temperatures in excess of 120ºF.

4.  Store cylinders in well ventilated areas.

  ADDITIONAL WARNINGS

1.  Make sure torch is cool before tightening or removing burner head, or before installing or removing accessories. Using a low flame can 

cause damage to the burn tube and ignition system.

2.  Check all joints and couplings periodically to insure against loose connections. With valve open, without lighting, test all connections 

with soapy water. If bubbles appear, gas is leaking and torch must be repaired. NEVER USE A FLAME TO CHECK FOR LEAKS. Make 

this test in a well-ventilated and spark-free area, and where there are no open flames.

3.  In cold weather the size of the flame will be smaller. To produce a larger flame, pre-warm the cylinder to room temperature prior to use.

DO NOT DISCARD THESE WARNINGS AND INSTRUCTIONS | NE PAS JETER CES AVERTISSEMENTS ET CES INSTRUCTIONS

 NO DESECHE ESTAS ADVERTENCIAS E INSTRUCCIONES | NÃO DESCARTE ESTES AVISOS DE ATENÇÃO E INSTRUÇÕES

200 Old Wilson Bridge Road

Columbus, OH 43085

MagTorch.com

419832     02/20

Содержание MT200C

Страница 1: ...burns Never use the torch on or near combustibles Be careful around motor vehicles or any gasoline fired products and beware of hidden fuel lines and tanks Always make certain the torch is placed on a...

Страница 2: ...er may snap if the torch is dropped in which case the burner must be replaced STORAGE REMOVE CYLINDER FROM TORCH WHEN NOT IN USE 1 Make sure valve is closed by turning flame adjustment knob fully cloc...

Страница 3: ...les Chauffer une surface peut permettre la chaleur de se propager aux surfaces adjacentes qui pourraient tre combustibles ou se pressuriser lorsqu elles sont chauff es Toujours v rifier qu aucune pi c...

Страница 4: ...it causer une accumulation de gaz inflammable dont l inflammation provoquera une boule de feu susceptible de causer des blessures ou des dommages mat riels Ne pas ouvrir le robinet et laisser le gaz s...

Страница 5: ...ficie puede hacer que el calor pase a superficies adyacentes que pueden ser combustibles o se presuricen al calentarse Siempre aseg rese de que no se est n calentando piezas o materiales sin intenci n...

Страница 6: ...mente Si no se sigue esta instrucci n se podr a acumular gas inflamable el cual al encenderse podr a generar una bola de fuego que podr a causar lesiones corporales y da os materiales No abra la v lvu...

Страница 7: ...o calor seja conduzido para as superf cies vizinhas que podem ser combust veis ou se tornarem pressurizadas quando aquecidas Verifique sempre para que nenhuma pe a ou material seja aquecido inadvertid...

Страница 8: ...u o n o for cumprida pode ocorrer um ac mulo do g s inflam vel que quando aceso pode provocar uma bola de fogo causando acidentes pessoais e danos materiais N o abra a v lvula nem permita que o g s fl...

Отзывы: