![Magtek ExpressCard 3000 Скачать руководство пользователя страница 17](http://html2.mh-extra.com/html/magtek/expresscard-3000/expresscard-3000_preventive-maintenance-procedure_3655217017.webp)
3 - Preventive Maintenance Procedure (EC3000)
ExpressCard 3000| Instant Issuance Card Personalization System | Preventive Maintenance Procedure
Page 17 of 24 (
D998200294-10
)
3.6
Service the Hopper Module
Follow these steps to service the hopper transport:
1)
Use the
MCP Commands
page (see
D99875607 ExpressCard 2000 / ExpressCard 3000
Hardware Service Manual
) to move the hopper shuttle from the front to the rear of the device to
verify the movement is smooth and there is no belt slippage.
2)
Only if the hopper transport rods are dirty, wipe off the dirt with a soft, lint-free cloth.
3)
Check the hopper transport drive belt for signs of damage. If it is damaged, contact MagTek Support
Services for a replacement.
3.7
Service the XY Transport Module
Do not lubricate the EC3000’s gears, shafts, or bearings. They are made of self-
lubricating material, and lubricants can damage their surfaces.
1)
If there is dirt, dust, or debris on the XY transport rods, wipe it off using a soft, lint-free cloth.
2)
Use the
MCP Commands
page (see
D99875607 ExpressCard 2000 / ExpressCard 3000
Hardware Service Manual
) to move the XY transport from the front to the rear of the device to
verify the movement is smooth and there is no belt slippage. Leave the transport at the rear of the
device.
3)
Check the XY transport drive belt for any signs of damage. If it is damaged, contact MagTek Support
Services for a replacement.
3.8
Service the Exit Transport Module
No additional service is necessary for the Exit Transport, other than the roller cleaning described in
section
3.9
Cool the Tipper Heater / Power Down the Device
The tipper heater operates at temperatures that are not safe to touch. Be sure to cool
down the tipper heater to a safe working temperature before working on or near it.
1)
On the touchscreen, navigate to
Menu
>
Settings
>
Tipper
to open the
Tipper
page.
2)
Press the
Set Heater OFF
button to turn off the tipper heater.
3)
Note the value under
Current Tipper Temp
.
If the tipper temperature is 50°C or hotter, the
tipper heater is not safe to touch.
4)
Take note of the current time, and plan your work to allow enough time for the tipper heater to cool,
which can take up to 15 minutes. You may be able to use compressed air to cool it more quickly.
5)
Power down the device.