3 - Installation and User Guidance
DynaGlass| Payment Terminal | PCI PTS POI Security Policy
Page 12 of 22 (
D998200455-10
)
3.3
Environmental Conditions
The environmental conditions for the device to operate normally are specified in
D998200439 DynaGlass
Installation and Operation Manual
, available from MagTek. The table below summarizes those
conditions:
Parameter
Value
DC Power
5V, 1A
Operating Temperature
0℃ to 50℃
Storage Temperature
-10℃ to 60℃
Humidity
10% < RH <90% (40℃)
The security of the device is not compromised by altering the environmental conditions outside the stated
operating ranges above. However, any temperature or operating voltage outside the values in the table
below will trigger environmental security protections, resulting in a tamper condition. The device will
need to be returned to the manufacturer for inspection before this condition can be cleared.
Parameter
Value
Secure temperature
-60℃ to 120℃
Secure operating voltage
2.1V to 3.8V