Install the DFP sensor so that its keyway is pointing towards the top cover when the follower arm is
half way through its travel.
DFP-2
To find the electrical center point of pot rotation, use a digital multimeter type ohm meter to measure
from the white wire (wiper), to the red or black wire. Turn the potentiometer shaft until the meter
reads 500 ohm. Install the DFP-2 sensor so that at the 500 ohm meter reading, the follower arm is
halfway through its travel.
Figure 5
Follower Arm Electrical Connections
5.3
Follower Arm Control Setup
The control adjustments marked with an underline on the label are the only ones needed for follower arm
adjustment (see Figure 6). Stop time and Stop multiplier apply to all operating modes and are not
distinctively marked.
Figure 6