There are many varieties of corn grown around the world.  Each variety has unique characteristics 
including the shape and size of the kernel.  Your stove will burn more consistently with a small to 
mid-size kernel corn.  If the kernel size of the corn varies greatly or if you switch sources frequently, 
you will get a less consistent burn, which will require more attention to the draft setting on your stove.  
Therefore, purchasing corn from the same source will help achieve a more consistent burn.  

DO NOT 

USE CORN WITH A HIGH WAX CONTENT! 

 

WOOD PELLETS 

 

9

 

Be consistent in your wood pellet fuel supplier.  Wood pellets will vary in content and burn 
characteristics from supplier to supplier.  A consistent supply of wood pellets will require fewer 
adjustments to the draft of the stove. 

 

9

 

Check your wood pellets for foreign objects.  Your stove warranty will not cover damage done to your 
stove due to foreign objects in the fuel supply. 

 

9

 

Store your wood pellets in a dry place to prevent them from absorbing excess moisture. 

 

9

 

Vacuum the hopper out after every 6-7 bags to eliminate buildup of sawdust.  More often if the wood 
pellets are poor quality.  If sawdust is a problem you will have to screen each bag of fuel for a 
consistent feed. 

 

9

 

Wood pellets vary from supplier to supplier in ash content from less than 1% to 3% or more.  Low ash 
content pellets will allow you to burn the stove longer between cleanings.  Only wood pellets 
manufactured to the Association of Pellet Fuel Industries (A.P.F.I.) standard for residential pellet fuels 
are recommended.  Look for A.P.F.I. registration number on the back of pellets.  Consult your local 

MagnuM 

reseller for more information on approved wood pellet fuel. 

 

9

 

It is strongly recommended not to keep a supply of wood pellets over the summer months.  Moisture 
will build up and cause problems in the fall with your appliance operation.  Make sure that your 
supplier is not selling you left over fuel or fuel that has been out in the rain. 

 
 
 
 

When you receive your MagnuM Corn/Biomass/Wood Pellet Stove

, Pedestal unit, Leg unit or 

Fireplace Insert

, be careful to inspect all parts and components to make sure that nothing was 

damaged or lost in shipment.  If there was shipping damage, be sure to report it to your MagnuM 
reseller, or the shipping company that delivered your unit.  

Freight damage claims must be made to 

UNPACKING YOUR MAGNUM CORN/BIOMASS/WOOD PELLET UNIT

 

the Freight Company immediately.

  If parts are missing contact your local MagnuM reseller or 

contact the factory right away.  

Your satisfaction is our top priority

 
To uncrate your 

MagnuM appliance

 

1)

 

Cut the banding straps and open the carton lid. The carton is stapled to the wood pallet so it will be 
necessary to pull the cardboard loose from the pallet. Remove the crating box carefully lifting up over 
the top of the unit. Be careful not to scratch the unit with the staples. Remove the wood blocks and 
plastic. We strongly urge you to recycle the packaging materials to help protect the environment. 
 

Содержание Winchester WINACP

Страница 1: ...e pressure All chimney connections elbows and fittings must be airtight Proper venting practices must be followed Consult with a venting professional 9 Ashes must be disposed of in a metal container w...

Страница 2: ...res 36 Glass Maintenance Adjustment Removal and Replacement 37 Circuit Board Functions 38 39 Setting the Draft 40 Wiring Diagram AC DC 41 42 Draft Slide Gate Adjustment 43 Solar Panel Connections 43 I...

Страница 3: ...American Energy Systems Inc manufacturer of the MagnuM Winchester Appliances reserves the right to alter its products their specifications and or price without notice Safety tested and EPA exemption t...

Страница 4: ...tove or it could be that there is a serious lacking of good quality air in the home caused by negative pressure If you have done any remodeling or if this is a newer home it is a very real possibility...

Страница 5: ...d If you are burning fuels not approved for this appliance it will void the warranty and no service warranty will be allowed 9 The MagnuM models will burn high ash content fuels but will require addit...

Страница 6: ...ntent periodically to maintain the proper dryness 9 Check your corn for foreign objects Your stove warranty will not cover damage done to your stove due to foreign objects in the fuel supply 9 Do not...

Страница 7: ...n cleanings Only wood pellets manufactured to the Association of Pellet Fuel Industries A P F I standard for residential pellet fuels are recommended Look for A P F I registration number on the back o...

Страница 8: ...le you are attaching the leg The casting could break if bound or dropped NOTE It is best to attach the legs on one side first and then lift the unit up level to attach the other side You can also atta...

Страница 9: ...ection must be 3 8 inch minimum thickness non combustible material or equivalent extending beneath heater and to the front side rear as indicated CHIMNEY AND CONNECTOR 3 LISTED PELLET VENT ONLY NOTE R...

Страница 10: ...urface The exhaust gases are not hot enough to ignite grass plants or shrubs located in the vicinity of the termination The grade surface must not be a lawn Distance from bottom of termination and pub...

Страница 11: ...h should not exceed 30 feet Diagram 11 1 Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1 0 Horizontal Pipe 1 x 2 1 3 ft Vertical Straight Pipe Actua...

Страница 12: ...mer s responsibility to make sure that there is adequate fresh air to the home so that the MagnuM appliance does not become the fresh air source 4 Only non combustible piping 3 inches in diameter is a...

Страница 13: ...local building codes fire codes and the safety listing tag on the inside hopper lid An outside air source must be connected to the stove and can be brought in through the sidewall or vented crawl spa...

Страница 14: ...THE FOLLOWING REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME 1 Stove must be permanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently el...

Страница 15: ...the pellet vent manufacturer s instructions Connect the pipe and lock the joints as directed by the pellet vent manufacturer and secure the vent pipe to the flue collar on the back of the stove Add a...

Страница 16: ...te The pipe lengths shown are for reference only Your actual pipe length requirements may differ SINGLE WALL PIPE SHALL NOT BE USED FOR ANY INSTALLATION HORIZONTAL INSTALLATION SHALL BE A MAXIMUM OF 5...

Страница 17: ...and presence of all necessary parts including a chimney cap prior to making the connection 3 This stove may be connected to an existing ceiling mounted factory built chimney with a diameter of 4 6 or...

Страница 18: ...sh buildup premature failure of exhaust system staining of the house siding and serious creosote buildup This installation should not be used in a cold climate area Storm Collar Note This type of inst...

Страница 19: ...wo terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or higher settin...

Страница 20: ...to the two terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or highe...

Страница 21: ...21 MAGNUM WIN INSERT INSTALLATION...

Страница 22: ...22 WIN INSERT INSTALLATION cont Siding Use only rigid Pellet Vent pipe Framing Chimney cap Storm Collar Seal Plate 3 75mm Minimum Clearance Around vent 6 150mm min 16 375mm minimum 6 150mm minimum...

Страница 23: ...t use some type of supp bolt to hold and lev the unit not provided ort el For a raised Hearth you can have a decorative skirting made by your installer to finish off the front of the unit The skirting...

Страница 24: ...resh air intake either out the back of the fireplace cavity or down and out to an outside air source Running the fresh air up and out the top of the chimney can cause excessive draft issues Your insta...

Страница 25: ...25...

Страница 26: ...Fireplace Insert Shroud Installation Diagram 26...

Страница 27: ...27 Thermostat wire connection Low voltage thermostat Molex Plug 24 volt thermostat hookup...

Страница 28: ...to prevent moisture from reaching terminals see diagram 8 Connect the red positive lead to the positive battery terminal 9 Connect the black negative lead to the negative battery terminal 10 Reconnec...

Страница 29: ...is not started within the minimum cycle time the auger will stop feeding and you will need to start the cycle over again Pushing and holding the auger switch allows you to prime the auger and add fue...

Страница 30: ...n allows you to prime the auger and add fuel to the firepot automatically Press and hold the button until you have the right fuel load Do not continue to hold the auger button under normal operation a...

Страница 31: ...moving the control switch to the desired operating position B Select the most efficient burn by adjusting the air damper control rod in or out An air damper closed too much will produce a lazy and sl...

Страница 32: ...LEANERS ALLOW ASH TO ESCAPE INTO THE ROOM AIR HOWEVER VACUUMING Use an approved Ash vacuum system IS RECOMMENDED OCCASIONALLY TO AID IN SEASONAL CLEANING AND KEEP THE UNIT FREE OF EXCESS ASH DISCARD T...

Страница 33: ...ldup of ash After cleaning push the rake handle in until it stops COMBUSTION BLOWER Over the course of the heating season dust and ash may collect on the blades of the combustion blower Periodically t...

Страница 34: ...fan blowe on the blades during the heating season This must be vacuum e convection blower will need to be cleaned regularly as the pet ha dings and cause premature wear overheating and failure of the...

Страница 35: ...that they will be ignited in the chimney and produce damage to the chimney or even possibly destroy the home Clean the chimney as often as needed and never go more than one 1 year without a flue clea...

Страница 36: ...unit overheats it will shut itself down safely The unit may not be restarted until it has cooled and the reset button is depressed See Thermodisk location section If the auger does not turn after cle...

Страница 37: ...is not sitting on top of any obstructions The glass will break when tightening the screws if the glass is on the gasket Hold the glass toward the top of the door glass channel when tightening CLEANIN...

Страница 38: ...oad in the firepot The unit is not designed to be operated for long periods of time on the highest heat level setting Optimum efficiency is achieved by using lower settings 2 or 3 It is also recommend...

Страница 39: ...ee 3 separate modes of operation switch located on top of board The manual setting allows the operator to choose heat level setting changes The T STAT setting allows the operator to set the high heat...

Страница 40: ...the flame again If the status of the flame has not changed move the damper another 1 8 until you get a clean dancing flame If moving the damper does not change the fire you might have negative pressur...

Страница 41: ...AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT 41 DHC 3000 AC board...

Страница 42: ...42 DC MODEL DDC 3000 WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...

Страница 43: ...hown When the gate is in the fully open position the plate will be against the mounting plate as shown If the unit needs a draft correction adjustment loosen the bolts see above and then rotate the sl...

Страница 44: ...lling the new igniter hand tighten the igniter and then apply slight pressure to secure the threads Do not over tighten the igniter assembly If you over tighten the igniter assembly it may ruin the ig...

Страница 45: ...the door latch rod and or the door hinges Replace the door gasket if necessary 9 Check for blockage in the air inlet tube or exhaust pipe Clean out as needed 9 Check combustion exhaust blower impeller...

Страница 46: ...witch or relay 9 Check contents of the hopper Add fuel if necessary 9 Check all operations fuses re set manual high limit thermodisk 9 Clean out auger system 9 Have your MagnuM reseller diagnose the p...

Страница 47: ...e home 9 Clean the glass when the unit is not running 9 Seal any leaks in the exhaust system with RTV high temperature silicone sealer 9 Use approved ash vacuum 9 Correct negative pressure situation 9...

Страница 48: ...fuel Lack of clean combustion air Dirty or plugged stove or venting Poor exhaust vent configuration Negative pressure present in the home Exhaust fan motor going out Use combustion enhancement system...

Страница 49: ...Fan MF3541 MagnuM Baby Countryside WIN AC Convection blower RP2045 F 110 N O POF Switch interchangeable with F 140 F 150 RP2050 L 225 N C Switch manual reset MagnuM Baby C S WIN Essex RT080 MagnuM Ba...

Страница 50: ...ility under this warranty is limited to the repair or replacement of the covered defective part The purchaser shall assume all costs related to shipping the replacement parts or return of the unit to...

Страница 51: ...51 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...