ADDING ENGINE OIL
1.
Place the generator on a firm, level surface.
2.
Remove the oil fill cap/dipstick. Clean the area
around the oil fill cap and wipe the dipstick
clean.
3.
Insert the dipstick in oil filler neck. Do not thread
into filler neck. Remove the dipstick, and check
the oil level.
3.
If oil is needed, carefully add oil to the bottom of
the oil filler neck, below the threads. While
filling, stop to check oil level. DO NOT overfill.
4.
Insert oil fill cap/dipstick and secure tightly.
5.
Check engine oil level before each use of the generator.
OPERATING THE GENERATOR
Before operating the generator, the engine oil level will need to be checked and gasoline will need to be added to the
unit.
CURRENT
(AMPS)
MAXIMUM CABLE LENGTH (FT)
#10
#12
#14
#16
5
10
15
20
600
1200
1800
2400
LOAD IN
WATTS
VOLTS
120
240
120
240
120
240
120
240
225
455
115
225
75
151
57
110
140
285
70
140
47
95
36
70
90
180
45
90
30
60
-
-
60
120
-
-
-
-
-
-
3.
Tighten the gasoline cap after filling the fuel tank.
ADDING GASOLINE
1.
Remove the gasoline cap.
2.
Carefully fill the fuel tank with UNLEADED gasoline. DO NOT use premium gasoline. DO NOT overfill. Allow
approximately 1/2” tank space for fuel expansion.
EXTENSION CORD SELECTION CHART
Keep extension cords as short as possible, preferably less than 15 feet long, to prevent voltage drop and possible
overheating of wires. Use only high quality, well-insulated, three-wire, grounded cord sets to connect equipment to
the generator.
LOWER
LIMIT
UPPER
LIMIT
12
WARNING
DO NOT fill fuel tank near an open flame, while smoking, or while engine is running. DO NOT fill tank
in an enclosed area with poor ventilation. Doing so may result in serious personal injury or death.
Содержание MPG 6600
Страница 1: ...PORTABLE GENERATOR MPG 6600 OPERATING PARTS MANUAL...
Страница 24: ...REV C PART NO 26128 02 04 09...