9
STARTING THE PUMP
Before starting the pump, add engine oil and gasoline. See page 11 for instructions on how to properly fill the unit
with engine oil.
1. Attach suction and discharge hoses.
DANGER
CARBON MONOXIDE: USING A GENERATOR INDOORS CAN KILL YOU IN MINUTES!
2. Fill up pump casing with water by removing the fill cap on top of the pump.
3. Open the fuel valve.
4. Turn engine switch on.
5. Open the throttle.
6. Pull starter rope.
7. As engine begins to warm-up, open choke.
8. Open throttle fully to operate.
OPERATING THE PUMP
The pump should begin pumping water within a minute. The longer the suction hose and higher the pump is above
water, the more time it will take to begin pumping.
If the pump does not prime, check for loose fittings or air leaks in the suction hose. Make sure strainer in water is
not blocked.
WARNING
Never pump volatile or corrosive chemicals or solutions with this pump. These fluids
could create serious safety, health and environmental hazards. High pressure
increases the chance of pump explosion which may result in serious personal injury.
STOPPING THE PUMP
1. Reduce engine rpm to idle by moving throttle to the right.
2. Turn engine switch off.
3. Close fuel valve.