Specifications

 

Specifications 

Working principle 

CO

2

NDIR 

PM

Laser scattering principle 

Measurement range 

PM2.5

0~1000μg/m³ 

CO

2

0~5000ppm 

Temperature

-10

~50

 

Humidity

0%~95%RH 

PM2.5 Measurement accuracy 

≤ 100μg/m³

±10μg/m³ 

> 100μg/m³

±10% reading

Reference Instrument TSI 8530

25±2

℃,

50±10%RH

 

CO

2

 Measurement accuracy 

±

50ppm+5% of reading

@ 0~50

 

Temperature Measurement 
accuracy 

±1

 

Humidity Measurement accuracy 

±8%RH 

PM Response time T90 

≤8s 

CO

2

 Response time T90 

<120s 

Working condition 

-10~50

℃,

0~95%RH

(

Non-condensing

)

Storage condition 

-20~60

℃,

0~95%RH

(

Non-condensing

)

Working voltage 

12V DC(24V DC available) 

Working current 

<140mA 

Standby current 

≤90mA 

Signal Output 

RS485 

Installation hole distance 

60mm

standard

 

Dimension 

86*86*24.9 mm 

Lifetime 

PM

≥5 years 

CO

2

≥10 years 

Содержание M9-IAQS

Страница 1: ...Compatible with push button and touch screen operation Using standard 86 box size thickness 24mm PM2 5 CO2 RH T etc multiple sensors can be optionally selected With fresh air control function three l...

Страница 2: ...530 25 2 50 10 RH CO2 Measurement accuracy 50ppm 5 of reading 0 50 Temperature Measurement accuracy 1 Humidity Measurement accuracy 8 RH PM Response time T90 8s CO2 Response time T90 120s Working cond...

Страница 3: ...ions and Interface Definition 1 Dimensions Unit mm tolerance 0 2 mm 2 Pin definition No Pin Description 1 TA Communication port RS485_TA 2 TB Communication port RS485_TB 3 12V Power input 12VDC 24VDC...

Страница 4: ...agnumFirst com 5 11 UI Interface Description Parameter Range corresponding to color LIST Gas Level Range Color PM2 5 g m Good 0 75 Just so so 75 115 Bad 115 CO2 ppm Good 0 600 Just so so 600 1000 Bad...

Страница 5: ...o There are four modes manual intelligent mute and periods Default is manual mode Long press till the buzzer off then is WIFI status 3 Operation Instructions 1 Switch on and off press and hold the for...

Страница 6: ...de The fan speed switched by the user Despite the time period and air quality The fan speed can be adjusted by the The adjustment range is low medium high 6 Mute mode The fan runs at low speed and can...

Страница 7: ...ecting Cable connect the corresponding cable to the controller s RS485 interface according to the interface definition as shown below Step 3 Match the two holes in the controller with the hooks in the...

Страница 8: ...r or rub it against hard objects during use otherwise it may cause damage to the controller s external light and damage Do not place the controller in a dusty environment to avoid dust accumulation in...

Страница 9: ...Sending by controller is fixed as 11H Length Length of frame bytes data length 2 including CMD IP DATA Command Command is fixed as 55H Address Controller address is 1 254 default is 01H Data Data of...

Страница 10: ...tration DF6 DF7 0 5000 ppm Indoor Temperature DF8 DF9 0 600 Corresponding value 100 10 C 10 0 50 0 one decimal place is reserved Indoor Humidity DF10 0 95 0 95 Indoor HCHO Concentration DF11 DF12 Rese...

Отзывы: