30

 

 

 

 

Startup/ normal operation 

When the circuit board is energized (the On/Off button is pushed), the start up cycle is initiated.   This starts a timed 
8-15 minute cycle which allows the unit to light.  If the unit is on AC power, the automatic ignition system will 
energize.  The igniter (optional feature) will glow red in the firepot for 10 minutes and then shut off to protect the 
igniter.  If the unit is on DC back up power the automatic ignition system will not work and the unit will have to be 
lit manually. If the proof of fire thermodisk has not reached operating temperature, the unit will go into the shut 
down mode.  The circuit board is programmed to start on the proper feed rate no matter where the heat level is set.  
The unit should be set to the # 2 or #3 heat level for the first 45 minutes. To restart the system if it does not light, 
push the ON/OFF button and the startup sequence will start again.  If you open the door, it will stop the startup 
sequence. 

The circuit board is programmed to start on the number 2 heat setting no matter what the advance heat setting is on. 

NOTE:

 Make sure that the wall thermostat is turned up so that the unit will start. (if using T-STAT or AUTO) 

Once the unit is operating at the proper temperature (usually 10-15 minutes), the circuit board switches from the 
start up cycle to normal operation.  Then the manual draft slide can be set for the right fuel load in the firepot. 

The unit is not designed to be operated for long periods of time on the highest setting.  Optimum efficiency is 
achieved by using lower settings (2 or 3).  It is also recommended that the unit not be run for extended periods of 
time on the number 1 setting.  The draft blower and venting will fill up with fly ash after a long period of time.  It is 
recommended to run the unit on a higher setting (2 or 3) once a week.  Run it this way for a few hours to clear the 
venting and draft blower.   

With all models, the manual draft will have to be adjusted when the higher (4-5) heat settings are used.  The circuit 
board will automatically change the draft and also the room air speed when you change heat settings. 

If you open the door, ash pan door, hopper lid, have negative or positive pressure in the home or place the unit in a 
drafty location the vacuum pressure switch will shut off the auger and the unit will go out.  You can override the 
circuit board by pressing the start button or On/Off button for several seconds and the unit will re-set itself.  If the 
unit does not respond, then the pressure switch will have to be re-set by shutting the unit down, unplugging the 
power and then starting over again. 

 

Shutdown 

To shut the unit down simply turn the heat setting knob to the off position and the system will enter the shut down 
mode.  

The room fan and exhaust blower

 will continue to operate until the low limit cool down sensor tells it that 

the fire is out.  Then the entire system shuts down.  

 

 

  

 
 
 
 
 
 
 
 
 
 
 

CIRCUIT BOARD FUNCTIONS (how does the circuit board operate?) 

Before starting up the Magnum Wood Pellet unit again, it is important to remember to clean out the 
firepot, empty the ashes, clean out the heat exchangers, vacuum out the hopper if needed and fill the 
hopper with fuel.  

Содержание Baby Countryside Corn/ Biomass / Wood Pellet...

Страница 1: ...roper venting practices must be followed Consult with a venting professional 9 Ashes must be disposed of in a metal container with a tight fitting lid 9 All minimum clearances to combustibles must be...

Страница 2: ...1 Wiring Diagram AC DC 32 33 Draft Slide Gate Adjustment 34 Igniter Replacement 35 Trouble Shoot Guide 35 37 38 39 Magnum Replace Parts List 40 Warranty 41 Service Record 42 TESTING CERTIFICATION INFO...

Страница 3: ...products is very much appreciated Many of our Dealers have referral rewards available and I encourage you to ask your local dealer how to get involved in helping make our country energy self sufficien...

Страница 4: ...n the home It can be as simple as the air adjustment not set properly on the side of the stove or it could be that there is a serious lacking of good quality air in the home caused by negative pressur...

Страница 5: ...5 make sure that there is nothing mechanical wrong with the appliance and then determine your need for proper fresh air Your dealer can contact the factory with any questions that he might have...

Страница 6: ...fuels not approved for this appliance it will void the warranty and no service warranty will be allowed The Magnum models will burn high ash content fuels up to 5 but will require additional maintena...

Страница 7: ...the proper dryness Check your Corn for foreign objects Your stove warranty will not cover damage done to your stove due to foreign objects in the fuel supply 9 Do not carry your corn supply over into...

Страница 8: ...from supplier to supplier in ash content from less than 1 to 3 or more Low ash content pellets will allow you to burn the stove longer between cleanings Only wood pellets manufactured to the Associat...

Страница 9: ...combustible material or equivalent extending beneath heater and to the front side rear as indicated CHIMNEY AND CONNECTOR 3 LISTED PELLET VENT ONLY NOTE REGARDLESS OF STOVE CLEARANCE VENT PIPE MUST AL...

Страница 10: ...nature of grade surface The exhaust gases are not hot enough to ignite grass plants or shrubs located in the vicinity of the termination The grade surface must not be a lawn Distance from bottom of te...

Страница 11: ...esponsible for Determining proper total equivalent pipe length depending on installation conditions Component Equivalent Length Equivalent Pipe Length Horizontal Straight Pipe Actual Length in ft x 1...

Страница 12: ...equate fresh air to the home so that the Magnum appliance does not become the fresh air source 4 Only non combustible pipe 3 inches in diameter is approved to use for outside air connections straight...

Страница 13: ...the stove and can be brought in through the sidewall or vented crawl space Flexible or rigid pipe should be used and will connect to the adaptor on the back of the stove See air inlet location under...

Страница 14: ...be permanently bolted to the floor 2 Stove must have permanent outside air source 3 Stove must be permanently electrically ground to the steel chassis of the mobile home 12 ga or larger wire 4 All ve...

Страница 15: ...er the pipe manufacturer s instructions Connect the pipe and lock the joints as directed by the pipe manufacturer and secure the vent pipe to the flue collar on the back of the stove Add a small bead...

Страница 16: ...LANTS OR OTHER COMBUSTIBLES Note The pipe lengths shown are for reference only Your actual pipe length requirements may differ SINGLE WALL PIPE SHALL NOT BE USED FOR ANY INSTALLATION HORIZONTAL INSTAL...

Страница 17: ...es and presence of all necessary parts including a chimney cap prior to making the connection 3 This stove may be connected to an existing ceiling mounted factory built chimney with a diameter of 4 6...

Страница 18: ...s ash buildup premature failure of exhaust system staining of the house siding and serious creosote buildup This installation should not be used in a cold climate area Storm Collar Note This type of i...

Страница 19: ...back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or higher settings When the room tem...

Страница 20: ...two terminals on the back of the control panel When the room temperature drops below the thermostat setting the thermostat switch will close allowing the stove to operate at the medium or higher setti...

Страница 21: ...terminal 10 Reconnect the 110 volt AC power The stove is now ready for 12 volt back up and will switch automatically to 12 volt operation when AC power is lost When AC power is restored the stove will...

Страница 22: ...uger will stop feeding and You will need to start the cycle over again Pushing and holding the Auger switch allows you to prime the auger and add fuel to the firepot automatically This can be done app...

Страница 23: ...ger and add fuel to the firepot automatically This can be done app 1 minute after pushing the on off start button The unit starts automatically on the low heat setting When you have started the unit a...

Страница 24: ...r settings An air damper closed too much will produce a lazy and slow flame Adjusted properly the flames should be bright and lively Altitude and fuel types greatly affect the amount of air required O...

Страница 25: ...ME VACUUM CLEANERS ALLOW ASH TO ESCAPE INTO THE ROOM AIR HOWEVER VACUUMING IS RECOMMENDED OCCASIONALLY TO AID IN SEASONAL CLEANING AND KEEP THE UNIT FREE OF EXCESS ASH DISCARD THE VACUUM BAG AFTER EAC...

Страница 26: ...they should be inspected and vacuumed clean The combustion blower is accessed by opening the stove s right side panel and then removing the inspection caps or the exhaust manifold cover See figure bel...

Страница 27: ...spected cleaned GASKETS INSPECTED Inspected or replaced DOOR GLASS CLEANED INSPECTED V CHIMNEY CLEANING A Creosote Formation Any time a wood or Biomass product is burned slowly tar and other bi produc...

Страница 28: ...mproper make up air for the home improper venting or failure to clean the 3 exhaust in the stove will cause the pressure switch to shut off the fuel feed To resume operation it is necessary to locate...

Страница 29: ...e sure that the glass is not sitting on top of any obstruction The glass will break when tightening the screws if the glass is on the gasket Hold the glass toward the top of the door glass channel whe...

Страница 30: ...hest setting Optimum efficiency is achieved by using lower settings 2 or 3 It is also recommended that the unit not be run for extended periods of time on the number 1 setting The draft blower and ven...

Страница 31: ...s with the ability to use 3 separate programming features This programming must be done by a qualified factory trained technician Contact your local dealer to set up an appointment to have this done T...

Страница 32: ...l will build up in the firepot and eventually smother the flame If this happens or if you notice the firepot is filling up with partially burned fuel open the damper 1 8 at a time until the fire is cl...

Страница 33: ...33 AC MODEL WIRING DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT DC MODEL DDC 3000 WIRING DHC 3000 AC board...

Страница 34: ...34 DIAGRAM WARNING DISCONNECT POWER BEFORE SERVICING THIS UNIT...

Страница 35: ...s adjustment must be made by a qualified Magnum Service Tech When rotating the slide gate be careful not to damage the gasket Re tighten the bolts and check for leaks The Draft Slide Gate is not shipp...

Страница 36: ...he threads Do not over tighten the igniter assembly If you over tighten the igniter assembly it may ruin the igniter Crimp on the terminal ends and attach the terminal ends onto the wiring harness If...

Страница 37: ...access plates 9 Change to a better grade of fuel if necessary 9 Check that damper control knob is adjusted properly Pull out to increase fire burn 9 Push ash cleanout slides in 9 Check gasket seal ar...

Страница 38: ...l is dirty or wet Auger circuit board pressure switch or relay 9 Check contents of the hopper Add fuel if necessary 9 Check all operation fuses re set manual high limit thermodisk 9 Clean out auger sy...

Страница 39: ...house 9 Clean the glass when the unit is not running 9 Seal any leaks in the exhaust system with RTV high temperature silicone sealer 9 Use approved ash Vacumm 9 Correct negative pressure situation 9...

Страница 40: ...o much ash Dirty fuel Wet fuel Lack of clean combustion air Dirty or plugged stove or venting Poor exhaust vent configuration Negative pressure present in the home Combustion motor going out Use combu...

Страница 41: ...y Countryside T40 Essex Hopper Pressure Switch 42 RP2063 Magnum Baby Countryside AC unit Wire Harness assembly 58 RP2062 Magnum Baby Countryside DC unit Wire Harness assembly 58 RP2075 Magnum Baby Cou...

Страница 42: ...efective part The sole duty of the Manufacturer and liability under this warranty is limited to the repair or replacement of the covered defective part The purchaser shall assume all costs related to...

Страница 43: ...43 SERVICE RECORD DATE SERVICE OR CLEANING PERFORMED This record must be sent in when any warranty claims are made...