Magnum 2824 Скачать руководство пользователя страница 22

MAGNUM MASONRY MANUAL – MAY 1999                                                                                                                                                           PAGE  - 22 

FIREPLACE 

 

LIMITED WARRANTY AND 25 YEAR PROTECTION PLAN 

LIMITED WARRANTY 

This limited warranty will not become effective unless you have returned card within 30 days of purchase.  If you fail to do so 
you may make no claim under this warranty.  American Energy Systems, Inc. excludes and disclaims all implied warranties 
including, but not limited to, the implied warranty of merchantability.   
 
This American Energy Systems, Inc. MAGNUM fireplace was manufactured by American Energy Systems, Inc. For a period 
of five (5) years from the date of purchase, American Energy Systems, Inc. will warrant to the original consumer-purchaser 
that all steel components are free of defects in material and workmanship.  Warranty of grates, baffles, glass doors, glass fan 
assemblies, wiring, paint, or gasketing material is not provided for in this warranty. 
 
In the event of a defect within warranty the first year, American Energy Systems, Inc. will repair or at its option, replace the 
defective part entirely at its own expense.  Within the second year through the fifth year after purchase, American Energy 
Systems, Inc. will, at its option, repair or supply replacement parts on this schedule:  Second year, customer must pay one-fifth 
(1/5) of the current retail cost of repair or replacement; Third year, two-fifths (2/5); Fourth year, three-fifths (3/5), Fifth year, 
four-fifths (4/5).  American Energy Systems, Inc. will pay the balance of the expenses. 
 
After expiration of the above five-year warranty and through the 25

th

 year, American Energy Systems Inc. will sell to you 

F.O.B. its factory, a replacement part or parts (if available) at its then current minimum list price.  AMERICAN ENERGY 
SYSTEMS, INC. SHALL NOT BE REPSONSIBLE FOR ANY LABOR, TRANSPORTATION OR OTHER COSTS OR 
EXPENSES. 
 
Repair or replacement may be obtained by returning part or parts freight prepaid to the nearest MAGNUM dealer or if you 
require additional information regarding performance under this warranty you may contact American Energy Systems, Inc. at 
the address stated below. 
 
Magnum fireplaces have been designed for use with wood and coal only.  American Energy Systems, Inc. will not warrant 
performance of unit with manufactured or pressed logs. 
 
Discoloration and distortion of the inner firebox should be expected under normal use.  American Energy Systems, Inc. shall 
not be responsible for this natural occurrence. 

 

 
All warranties are null and void if components specified in installation manuals are not used and if installations are not in 
accordance with instructions furnished with units.  American Energy Systems, Inc. makes no representations or warranty 
regarding, and shall not be responsible for, any building code compliance.  The warranties shall not apply to the product or any 
component of the product which has been moved from its original place of installation. 
 
American Energy Systems, Inc. makes only the limited warranty stated herein.  The Purchase’s sole, exclusive remedy shall 
repair or replacement.  IN NO EVENT SHALL AMERICAN ENERGY SYSTEMS, INC. BE LIABLE FOR ANY COSTS, 
EXPENSES OR DAMAGES INDIRECT, INCIDENTAL OR CONSEQUENTIAL. 
 
Any implied warranties including, but not limited to the implied warranty or merchantability, shall extend only to the original 
consumer\purchaser and are here-by limited to the same duration, extend, and remedy, as the limited warranty provided herein. 
 
Some states do not allow limitations on how long an implied warranty lasts, or allow the exclusion or limitation of incidental or 
consequential damages, so the above limitations or exclusions may not apply to you.  This warranty gives specific legal rights.  
You may have other rights that vary from state to state. 
 
 

 

 

 

 

 

AMEREICAN ENERGY SYSTEMS, INC. 

      150 

Michigan 

Street 

SE 

      Hutchinson, 

 

MN 

55350 

Содержание 2824

Страница 1: ...tion requirements in your area CAUTION Never use gasoline gasoline type lantern fuel kerosene charcoal lighter fluid or similar liquids to start or freshen up a fire in this fireplace Keep all such liquids well away from the fireplace at all times If you are using processed solid fuel fire logs use only fire logs that have been evaluated for use in this type of fireplace Do not poke or stir the lo...

Страница 2: ...MAGNUM MASONRY MANUAL MAY 1999 PAGE 2 TABLE OF CONTENTS PAGE ...

Страница 3: ...has over the past 30 years earned its reputation for unmatched quality and efficiency The added features of this fireplace will enable you to have years of trouble free operation Please read this manual completely through before attempting to install this unit It will give you step by step instructions for proper installation and operation Sincerely Mike Haefner Owner American Energy Systems Inc ...

Страница 4: ...slab to prevent a heat trap Only masonry products or authorized components may be used in the construction of this fireplace COLD AIR PREVENTION In cold or higher elevation climates greater precautions against cold air infiltration must be taken Never consider that an uninsullated masonry wall will take the place of a standard properly insulated outside wall On an outside installation the wall dir...

Страница 5: ...ntel Remember to remove this insulation strip when cleaning out the fireplace chamber All loose mortar must be removed from the top of the fireplace Allow expansion room between the side of the unit and the front face brick Also allow expansion along the brick supported by the lintel bar A Foundation Concrete F Concrete Slab K Connector Pipe P Chimney Adapter B 8 x 8 x 16 Concrete Block G Electric...

Страница 6: ...pace with insulation or other materials NOTE The lower grill is recommended with every installation If it is not used the same 150 square inches of open area is required INSTALLING BLOWERS Two different styles of blowers are available for Magnum Fireplaces A hearth mount 465 cfm squirrel cage design or an interior mount low profile design NOTE Low profile fans tend to create more noticeable air tu...

Страница 7: ...f insulation must surround this slab if installed on an outside wall see Figure __ NOTE If an ash dump is to be used leave a 5 x 10 hole in the slab Construct the inner chamber wall using 4 x 8 x 16 lightweight Hadite block Note If installing adjacent to combustible materials leave at least 6 of open air space between the inner chamber s outside block wall and combustible surface Cover entire area...

Страница 8: ...ils SEE FIGURE __________ Position properly sized slab support over the flue extension so that the holes line up and that the plate overlaps the Hadite block 2 The slab support plates available from your Magnum reseller are constructed of 10 gauge steel Note This concrete slab form can be constructed out of other materials including plywood Proper support from below and caution to remove all combu...

Страница 9: ...t at this time We recommend using a non combustible mantle When laying up face brick on the sides and back allow at least 4 of space to be filled with loose fiberglass insulation If the face brick is being used on the outside of the building allow 6 of area to be insulated Make sure that this insulation surrounds the bottom slab below the frostline thus preventing any cold air conduction through t...

Страница 10: ...e fireplace flange The rods can be adjusted in height by placing shims underneath the rods to get your desired lintel height Place the Tri View lintel iron on the block or brick on each side of the fireplace and rest the lintel bar on the two 2 rods Make sure that you have allowed sufficient expansion room between the lintel iron and the top of the fireplace 1 or more is recommended IMPORTANT The ...

Страница 11: ...ould always remain at least three feet above a combustible roof and should never be less than 12 feet from the top of the fireplace If using a listed type HT Chimney the chimney installation procedures may be generally stated and instruct the installer to follow the procedures specified in the chimney manufacturer s installation manual and use all necessary parts specified for use with the listed ...

Страница 12: ...imum Footing Slab 48 wide X 72 Minimum Height from floor to bottom Fiberglass Insulation of slab 64 Lightweight Block This Height may vary with different installations Air Space Around Unit Warning Do not pack required air spaces with insulation or other materials ...

Страница 13: ...acing Applications Note Footings must be 6 larger per side of area needed for fireplace enclosure Footings must be a minimum of 12 thick Note Installation Dimensions may vary with different customer needs Lay out your installation before figuring footing and slab sizes Warning Do not pack required air spaces with insulation of other materials ...

Страница 14: ...pplications Note Footings must be 6 larger per side of area needed for fireplace enclosure Footings must be a minimum of 12 thick Note Installation Dimensions may vary with different customer needs Lay out your installation before figuring footings and slab sizes Warning Do not pack required air spaces with insulation or other materials ...

Страница 15: ...MAGNUM MASONRY MANUAL MAY 1999 PAGE 15 VERTICALLY ADJACENT INSTALLATIONS 16 OFFSET REQUIRED ...

Страница 16: ...l will adjust the fire burn rate 2 Crumple 8 to 10 pages of newspaper and place a small amount of kindling on top of this newspaper Then light the newspaper in a couple of places 3 After the kindling is well started place two or three small split logs on top These logs like any additional fuel should be placed at slight angles to one another keeping an airspace between the logs Make sure to keep l...

Страница 17: ...educing the fan speed you are not producing less heat but are simply receiving less circulation 8 When opening doors to refuel first open damper completely shut off the fan and slowly open both doors at the same time This will prevent you from drawing smoke into the house Important Note Never throw or drop logs onto the firebrick floor This will cause early deterioration or cracking of this protec...

Страница 18: ...ds to light the fire Ventilating fans exhaust hoods or central heating systems can cause fireplaces to smoke by stealing the fireplace s combustion air If the volume is enough they can reverse the flow of air in the fireplace and cause smoke Always use a rain cap to prevent any moisture from entering down into the chimney Fig 7 CARE OF GLASS DOORS Heat the ceramic glass doors slowly the first time...

Страница 19: ...oroughly cooled CREOSOTE Controlling the rate of burn in an efficient fireplace stove or insert allows in many cases improper flue or chimney temperatures When wood is burned slowly any excess moisture that can not be burned off inside the stove mixes with carbon and other organic materials to form creosote Creosote forms on the inside of the chimney as tiny water droplets mixed with a black tar l...

Страница 20: ...E THE ASSEMBLY IN FIG A B To adjust the right door simply pull on the steel shank to give it a little spring tension and then tighten the set screw on the steel collar using the 9 allen wrench provided Adjust the door so that the handle pulls the door up so that the gasket seals against the door frame DO NOT OVER TIGHTEN THE DOOR AS IT WILL TWIST THE CAST FRAME AND COULD CAUSE GLASS BREAKAGE LEFT ...

Страница 21: ...nwood Low Yes Yes Med Yes Chestnut yellow poplar Low Yes Yes Med Yes Southern yellow pine Douglas fir High Yes Yes Yes Yes Cypress redwood Med Med Yes Med No White cedar western red cedar Med Yes Yes Med Yes Eastern red cedar Eastern white pine western white pine Low Med Yes Med No Sugar pine ponderosa pine true firs Tamarac larch Med Yes Yes Med Yes Spruce Low Yes Yes Med Yes SOURCE U S FOREST PR...

Страница 22: ...NSES Repair or replacement may be obtained by returning part or parts freight prepaid to the nearest MAGNUM dealer or if you require additional information regarding performance under this warranty you may contact American Energy Systems Inc at the address stated below Magnum fireplaces have been designed for use with wood and coal only American Energy Systems Inc will not warrant performance of u...