background image

No.

Description

No.

Description

MI-76750-101

PULLY COVER

MI-76750-S01

LIGHT

MI-76750-102

COVER BASE R/L

MI-76750-S02

SELECTOR SWITCH

MI-76750-103

SWITCH TABLE

MI-76750-S03

STOP BUTTON

MI-76750-104

COVER BASE

MI-76750-S04

VARIABLE RESISTOR

MI-76750-105

HEAD

MI-76750-S05

BUTTON,YELLOW

MI-76750-106

CONTROL BOX

MI-76750-S06

PUSH BUTTON SWITCH

MI-76750-107

DOOR

MI-76750-S07

MOTOR INVERTER SWITCH

MI-76750-108

KNOB BOLT

MI-76750-S09

TERMINAL BLOCK

MI-76750-109

HINGE PIN

MI-76750-S10

AC MOTOR CONTROLLER

MI-76750-110

PANEL

MI-76750-S11

TRANSFORMER

MI-76750-111

BRARD

MI-76750-S12

CONTACTOR

MI-76750-901

CAP SCREW

MI-76750-S14

FUSE

MI-76750-902

PHILLIPS HEAD SCREW

MI-76750-S15

RELAY,2P

MI-76750-903

NUT M3

MI-76750-S16

RELAY,2P

MI-76750-904

NYLON NUT

MI-76750-S18

LIMIT SWITCH

MI-76750-905

HEX NUT

MI-76750-S19

POWER CORD

MI-76750-906

PHILLIPS HEAD SCREW 3/16"

MI-76750-S20

STRAIN RELIEF

MI-76750-907

PHILLIPS HEAD SCREW 1/4"

MI-76750-S21

RELAY,4P

PARTS LIST FOR MI-76750

Содержание MI-76750

Страница 1: ...MODEL NO MI 76750 OPERATINGMANAUL RPM...

Страница 2: ...ll visitors should be kept safe distance from work area 8 MAKE WORKSHOP KID PROOF with padlocks master switches or by removing starter keys 9 DON T FORCE TOOL it will do the job better and safer at th...

Страница 3: ...y and perform its intended function check for alignment of moving parts binding of moving parts breakage of parts mounting and any other conditions that may affect its operation A guard or other part...

Страница 4: ...d the power cord disconnected 20 Do not remove jammed cutoff pieces until blade has stopped ON OFF SWITCH PADLOCK To safeguard the band saw from unauthorized operation and to avoid accidental starting...

Страница 5: ...50 volts This tool is intended for use on a circuit that has an outlet that looks like the one illustrated in Sketch A in Figure 1 The tool has a grounding plug that looks like the plug illustrated in...

Страница 6: ...ool should comply with all local codes and ordinances Note In Canada the use of a temporary adaptor is not permitted by the Canadian Electrical Code GROUNDING PIN COVER OF GROUNDED OUTLET BOX METAL SC...

Страница 7: ...e for cord Ampere Rating Volta Total length of cord in feet 120V 240V 25ft 50ft 100ft 150ft 50ft 100ft 200ft 300ft Not More More Than Than AWG 0 6 6 10 10 12 12 16 18 16 16 14 18 16 14 12 16 16 14 12...

Страница 8: ...7 A Switch Plane B Depth Stop C Coarse Downfeed Handle D Table E Belt Tension Lever F Control box G Crank Handle A B C D E F G...

Страница 9: ...ltage 220V Phase 1 Phase Cycle 60HZ Type Induction Amps 6 6A Speed 1720RPM Power Transfer Belt Drive Power input 220V 3PH Swing 22 Spindle Travel 6 Spindle Taper MT 3 Rang of Speeds 150 2250RPM Table...

Страница 10: ......

Страница 11: ...ER SWITCH MI 76750 108 KNOB BOLT MI 76750 S09 TERMINAL BLOCK MI 76750 109 HINGE PIN MI 76750 S10 AC MOTOR CONTROLLER MI 76750 110 PANEL MI 76750 S11 TRANSFORMER MI 76750 111 BRARD MI 76750 S12 CONTACT...

Страница 12: ......

Страница 13: ...SE MI 76750 909 PHILLIPS HEAD SCREW MI 76750 214 SWITHC UP MI 76750 910 SET SCREW MI 76750 215 SWITHC DOWN MI 76750 911 PHILLIPS HEAD SCREW MI 76750 217 DEPTH STOP SCALE STUD MI 76750 912 HEX NUT MI 7...

Страница 14: ...5 7 6 7 I M W E R C S P A C 8 1 9 0 5 7 6 7 I M T F A H S R A E G 5 0 3 0 5 7 6 7 I M R E H S A W K C O L 4 2 9 0 5 7 6 7 I M K C O L E L D N A H 6 0 3 0 5 7 6 7 I M T U N X E H 5 2 9 0 5 7 6 7 I M T...