Product Installation Guide
Automatic Load Control Relay
M
9
-ALCR
OVERVIEW
WIRING
EXAMPLES OF USE
The Magnum M
9
-ALCR is a UL 924 listed emergency lighting control device. This device is designed to ensure a
“lights on state” during a power outage. The M
9
-ALCR senses when a power outage occurs and switches on the
connected emergency lighting load to full brightness, bypassing any normal lighting switches and dimmer controls.
ELECTRICAL SPECIFICATIONS
Dim Relay Output
(Violet / Red)
Dim Relay Input
(Violet)
SPST-NO Relay Output
(Black / Blue)
SPST-NO Relay Input
(Blue / Black)
Utility HOT Input
(Black)
Utility Neutral Input
(White)
SPST-NC Relay Out
(Red / Blue)
SPST-NC Relay Input
(Blue / Red)
(-)
(Gray)
(+)
(Red)
Rated for indoor use only. UL, cUL listed Emergency Lighting and Power under UL 924 at line voltages of 120 and
277 VAC, 60 Hz.
• Load Rating of 10A Max at 277 VAC
WARNING: Risk of electric shock! The M
9
-ALCR utilizes high voltage and should only be
installed by a qualified installer or electrician. Follow all local codes for installation and follow
the proper lockout/tag out procedures per NFPA Standard 70E.
1.
Turn off all electrical power supplying this equipment before working on or inside the equipment, including
the emergency lighting circuit. Always use a properly rated voltage sensing device to confirm that power is off.
2.
Feed the M
9
-ALCR wiring through the preferred mounting box knockouts.
3.
Attach the M
9
-ALCR to the exterior of the junction box or panel with the ½” threaded nipple.
4.
Wire the M
9
-ALCR according to the wiring diagram in the wiring section; follow all applicable national and
local electrical codes.
WARNING: Before terminating the AC power wiring verify the breakers for the normal power and
emergency power are in the off position and follow the proper lockout/tag out procedures per NFPA
Standard 70E
INSTALLATION
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the follow:
• READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
• Do not use outdoors
• Install this unit to an approved electrical enclosure only. This emergency device must be installed in
locations and at heights where it will not readily be subjected to tampering by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
• Do not use this equipment for other than intended use.
SAVE THESE INSTRUCTIONS
Emergency
Power
Utility
Power
Utility
Power
UL
1008
E508564
Normal
Panel
Normal /
Emergency
Panel
Magnum
UL924
M9-ALCR
NO
Utility Hot
Utility Neutral
Normal Sense
Output
Input
SR Driver
MLD
Light Fixture
(Normal /
Emergency)
Emergency
Power
Utility
Power
Utility
Power
UL
1008
Magnum
USR Relay
Normal
Panel
Normal /
Emergency
Panel
Magnum
UL924
M9-ALCR
NO
NC
Utility Hot
Utility Neutral
Normal Sense
Hot
Relay IN Hot
N
Dim (-)
Violet
Violet / Red
Black /Blue
Blue / Black
Blue / Red
Black
White
Red / B
lue
Dim (+)
Light Fixture
(Normal /
Emergency)
Configuration 2
Configuration 1
2.439
2.939
2.319
A
A
R.563
R.320
.060
.060
73.74°
.071
2.26°
2.94°
.044
.049
.824
SECTION A-A
1.250
.900
.550
D
C
B
A
A
B
C
D
1
2
3
4
5
6
7
8
8
7
6
5
4
3
2
1
THE INFORMATION CONTAINED IN THIS
DRAWING IS THE SOLE PROPERTY OF
<INSERT COMPANY NAME HERE>. ANY
REPRODUCTION IN PART OR AS A WHOLE
WITHOUT THE WRITTEN PERMISSION OF
<INSERT COMPANY NAME HERE> IS
PROHIBITED.
PROPRIETARY AND CONFIDENTIAL
NEXT ASSY
USED ON
APPLICATION
DIMENSIONS ARE IN INCHES
TOLERANCES:
FRACTIONAL
ANGULAR: MACH BEND
TWO PLACE DECIMAL
THREE PLACE DECIMAL
INTERPRET GEOMETRIC
TOLERANCING PER:
MATERIAL
FINISH
DRAWN
CHECKED
ENG APPR.
MFG APPR.
Q.A.
COMMENTS:
DATE
NAME
TITLE:
SIZE
B
DWG. NO.
REV
WEIGHT:
SCALE: 1.25:1
UNLESS OTHERWISE SPECIFIED:
SHEET 1 OF 1
Relay 2-1
DO NOT SCALE DRAWING
TESTING - FOR CONFIGURATION 2
MAINTENANCE
1. Switch 1 light off using wireless switch (M9-ESRP or M9-ASW1)
2. Press Test Button and Keep Depressed – Light will turn on to full brightness
3. Release button – Light will shut off
No maintenance is required to keep the MX-ALCR functional. However, regular testing should be performed.
NOTE: USE THIS
CONFIGURATION
(1) IF AT LEAST
5 SECONDS
SWITCH-OVER
DELAY TIME CAN
BE GUARAN-
TEED.
SR/DA+
SR/DA+
SR/DA-