Magnum Energy ME-PT1 Скачать руководство пользователя страница 4

ME-PT1 Instruction Sheet

© 2014 Magnum Energy, Inc.

Figure 4, ME-PT1 to ME-AGS-S Installation

12-volt

DC supply

fu

se

12-volt

DC supply

fu

se

External

Maintain Switch

External

Momentary Switch

One time push (or 

close): Gen runs for 

duration of RUN TIME 

HOURS period.

Coleman Air Conditioner Zone Control Box

ON

OFF

ON: Gen continues 

to run.

OFF: Gen stops 

once current RUN  

TIME HOURS cycle 

has been satisfied.

options

GEN connection 

pr12VDC 

from Zone Control 

Box when gen needs 

to start.

GEN

connection

GREEN (GND)
WHITE (L2)

BLACK (L1)

ZONE CONTROL BOX

115VAC IN

9

-PI

N

 PL

U

G

 T

O

 

U

PPE

R

 U

N

IT

FREEZE ROOM HE AT

SHED

COOL

SHED

TO

 U

S

E W

IT

H

 

LO

AD

 S

H

E

D

 

D

EVI

C

E R

EM

O

VE

 

JU

M

P

E

R

 A

N

D

 

CO

N

N

ECT

 T

O

 

N

.C

. CO

N

T

A

TCT

ROOM

SENSOR

FR

EE

ZE

 S

EN

S

O

R

PT1-AGS

Phone Splitter

(6-conductor)

ME-AGS-S

Remote Switch

(with Temp Sensor opened)

All grounds must be 

bonded together to 

ensure the ME-PT1 

works correctly

ME-PT1

AUTO GEN START

ENABLE

OFF

TEST

Содержание ME-PT1

Страница 1: ...ion To install the ME PT1 refer to Figure 1 and the steps below 1 Connect the red wire on the ME PT1 adapter to a 12 volt DC external switching device i e switch 2 Plug the ME PT1 adapter into the REMOTE purple port on the ME AGS N Info The remote temperature sensor that comes with the ME AGS N normally plugged into the AGS s REMOTE port is not used when a ME PT1 is connected Setup When using the ...

Страница 2: ...ion of run time cycle and then stops options PT1 AGS To Network port on Magnum inverter All grounds must be bonded together to ensure the ME PT1 works correctly GEN connection provides 12VDC from Zone Control Box when gen needs to start GEN connection GREEN GND WHITE L2 BLACK L1 ZONE CONTROL BOX 115 VAC IN 9 PIN PLUG TO UPPER UNIT FREEZE ROOM HEAT SHED COOL SHED TO USE WITH LOAD SHED DEVICE REMOVE...

Страница 3: ... the phone splitter s ports and then plug the remote switch using its communications cable into the phone splitter s other port 3 Connect the red wire on the ME PT1 adapter to a 12 volt DC external switching device i e switch Temperature Sensor Temperature Sensor cut open Figure 2 Locating Sensor Figure 3 Sensor Cut Open Setup 1 On the ME AGS S turn the START TEMP F adjustment clockwise to any tem...

Страница 4: ... current RUN TIME HOURS cycle has been satisfied options GEN connection provides 12VDC from Zone Control Box when gen needs to start GEN connection GREEN GND WHITE L2 BLACK L1 ZONE CONTROL BOX 115VAC IN 9 PIN PLUG TO UPPER UNIT FREEZE ROOM HEAT SHED COOL SHED TO USE WITH LOAD SHED DEVICE REMOVE JUMPER AND CONNECT TO N C CONTATCT ROOM SENSOR FREEZE SENSOR PT1 AGS Phone Splitter 6 conductor ME AGS S...

Отзывы: