MAGNITUDE LIGHTING T Series Скачать руководство пользователя страница 2

INSTALLATION GUIDE 

T-SERIES

120VAC / 12/24VDC

            

Magnitude, Inc.

Page 2 of 2

14711 Bentley Circle. Tustin, CA 92780

www.MagnitudeInc.com

[email protected]

DOC-GU-

XXXXX

 Rev. 1

Wiring Diagram

Do not install PWM low voltage 
controllers on the output without 
consulting with Magnitude Inc.

2

INPUT

120V AC 60Hz

With power turned off, route the 
input wires through a strain relief 
and connect one wire to black 
and one wire to white. for all wire 
connections use only UL listed 
wire nuts and connectors of 
suitable size and type. Connect 
the ground wire to the transformer 
green wire. 

3

4

Strain Reliefs

Output

Input

Output Connections 

Bring the wires of the light fixture through 

the other clamp connector and connect 
them to the driver wires - positive to 
the red (+ ) wire and negative to black 
( - ) wire. Measuring the output voltage 
without a load will result readings greater 
than the nominal voltage.

The transformer case MUST be 
grounded in accordance with the N.E.C

Dimming

Dimmable with any standard MLV / Incandescent 
TRIAC (Leading edge) dimmer switch. Dimmer 
switch is to be installed on the input (277VAC side) 
of the driver. For smooth dimming, 8W minimum 
load is required. Please visit our website for a full 
dimmer compatibility list www.magnitudeinc.com

Black

White

Green

Black

Red

Отзывы: