INSTALLATION GUIDE
T-SERIES
120VAC / 12/24VDC
Magnitude, Inc.
Page 2 of 2
14711 Bentley Circle. Tustin, CA 92780
www.MagnitudeInc.com
DOC-GU-
XXXXX
Rev. 1
Wiring Diagram
Do not install PWM low voltage
controllers on the output without
consulting with Magnitude Inc.
2
INPUT
120V AC 60Hz
With power turned off, route the
input wires through a strain relief
and connect one wire to black
and one wire to white. for all wire
connections use only UL listed
wire nuts and connectors of
suitable size and type. Connect
the ground wire to the transformer
green wire.
3
4
Strain Reliefs
Output
Input
Output Connections
Bring the wires of the light fixture through
the other clamp connector and connect
them to the driver wires - positive to
the red (+ ) wire and negative to black
( - ) wire. Measuring the output voltage
without a load will result readings greater
than the nominal voltage.
The transformer case MUST be
grounded in accordance with the N.E.C
Dimming
Dimmable with any standard MLV / Incandescent
TRIAC (Leading edge) dimmer switch. Dimmer
switch is to be installed on the input (277VAC side)
of the driver. For smooth dimming, 8W minimum
load is required. Please visit our website for a full
dimmer compatibility list www.magnitudeinc.com
Black
White
Green
Black
Red