background image

D I M E N S I O N A L   S P E C I F I C A T I O N S

I N C H E S   ( M M )

O - R I N G   ( S E A L )   S E L E C T I O N   C H A R T

12

9.30

(236)

4.18

(106)

3.38

(86)

3.77

(96)

4.03

(102)

8.34

(212)

Transmitter

Material

Code

Maximum

Temperature

Maximum

Pressure

Min.

Temp.

Recommended

For Use In

Not Recommended

For Use In

Viton

®

GFLT

0

+400° F @ 232 psig

(+200° C @ 16 bar)

750 psig @ +70° F

(51.7 bar @ +20° C)

-40° F

(-40° C)

General purpose, steam, 
ethylene

Ketones (MEK, acetone), 
skydrol fluids, amines, anhydrous
ammonia, low molecular weight
esters and ethers, hot hydrofluoric
or chlorosulfuric acids, sour HCs

EPDM

1

+250° F @ 200 psig

(+125° C @ 14 bar)

750 psig @ +70° F

(51.7 bar @ +20° C)

-60° F

(-50° C)

Acetone, MEK, skydrol fluids
anhydrous ammonia

Petroleum oils, di-ester base
lubricants, propane, steam

Kalrez

®

(4079)

2

+400° F @ 232 psig

+(200° C @ 16 bar)

750 psig @ +70° F

(51.7 bar @ +20° C)

-40° F

(-40° C)

Inorganic and organic acids 
(including HF and nitric), 
aldehydes, ethylene, glycols,
organic oils, silicone oils,
vinegar, sour HCs

Black liquor, hot water/steam, hot
aliphatic amines, ethylene oxide,
propylene oxide, molten sodium,
molten potassium

Simriz SZ485

(formerly

Aegis PF128)

8

+400° F @ 232 psig

+(200° C @ 16 bar)

750 psig @ +70° F

(51.7 bar @ +20° C)

-4° F

(-20° C)

Inorganic and organic acids
(including HF and nitric), 
aldehydes, ethylene, glycols,
organic oils, silicone oils,
vinegar, sour HCs, steam,
amines, ethylene oxide,
propylene oxide

Black liquor, Freon 43, Freon 75,
Galden, KEL-F liquid, molten
sodium, molten potassium

2.8

(55)

0.68 (17) Thread
Engagement

A

C

B

D

3

(76)

H

Aperture 

Model #

Antenna

Extension

(maximum “L”

dimension)

All

All

BSP

8th Digit

Dim A

Dim B

Dim C

0

1 (25)

2.3 (58)

11.1 (282)

3.0 (76)

1

4 (100)

5.1 (130) 14.0 (356)

5.9 (150)

2

8 (200)

9.1 (231) 18.0 (457)

9.9 (251)

3

12 (300)

13.1 (333) 22.0 (559) 13.9 (353)

Antenna Extension O.D.

Dimension D

TFE Rod

∅ 

1.625 (41)

PP Rod

1.50 (38)

All-Plastic

Rod

∅ 

1.625 (41)

Model #

Antenna

Extension

(maximum “L”

dimension)

3" Horn

4" Horn

6" Horn

8th Digit

Dim H

Dim H

Dim H

0

1 (25)

2.7 (51)

1

4 (100)

N/A

4.6 (117)

2

8 (200)

8.4 (213)

8.3 (211)

3

12 (300)

12.4 (315)

12.4 (315)

Aperture

2.95 (75)

3.75 (95)

5.75 (146)

DIELECTRIC RODS – inches (mm)

HORNS – inches (mm)

Содержание Pulsar R96

Страница 1: ...transmitters Enhanced performance and innovative diagnostics bring simplicity to an often complicated technology This latest entry into the radar level measurement field is designed to provide unpara...

Страница 2: ...iplied by the transit time divided by two Distance C Transit Time 2 then developing the level value by factoring in tank height and other configura tion information Figure 3 The exact reference point...

Страница 3: ...om the sensor reference point bottom of NPT thread top of BSP thread or face of flange to the bottom of the tank Refer to Figure 4 Ideally the 6 150 mm horn antenna should be used to ensure the best p...

Страница 4: ...uld illuminate the maximum liquid surface with a minimum striking other objects in the vessel including the tank wall Use these drawings to determine the optimum installation location O B S T R U C T...

Страница 5: ...0 68 17 Thread Engagement A C B D 3 76 H Aperture Model Antenna Extension maximum L dimension All All BSP 8th Digit Dim A Dim B Dim C 0 1 25 2 2 56 11 1 282 3 0 76 1 4 100 5 1 130 14 0 356 5 9 150 2...

Страница 6: ...ghout length no reducers Use only horn antennas sized to pipe ID 3 6 80 150mm 8 pipe can use a 6 horn Stillwell length must cover complete range of measure ment i e liquid must be in stillwell Welds s...

Страница 7: ...U R S T R A D A R S T O R A G E A N D I N T E R M E D I A T E H O L D I N G T A N K S CONDITIONS Calm Surfaces R E A C T O R S CONDITIONS Turbulence and Foam E N C L O S E D S U M P S CONDITIONS Turbu...

Страница 8: ...ause poor performance Tanks heavily cluttered with false targets mixers pumps ladders pipes etc During times of very low liquid levels of low dielec tric media the metal tank bottom may be detected wh...

Страница 9: ...NSI IEC 60529 2004 C22 2 No 0 4 2009 C22 2 No 0 5 2008 C22 2 No 30 2007 C22 2 No 94 2001 C22 2 No 213 2012 C22 2 No 1010 1 2009 CAN CSA 60079 0 2011 CAN CSA 60079 1 2011 CAN CSA 60079 11 2014 CAN CSA...

Страница 10: ...fieldbus Host System English Power Measured at instrument terminals HART General Purpose Weather proof Intrinsically Safe Explosion proof 11 VDC minimum under certain conditions refer to I O Manual 58...

Страница 11: ...rsion 0x01 P E R F O R M A N C E A N T E N N A S P E C I F I C A T I O N S F U N C T I O N A L P H Y S I C A L T E M P E R A T U R E P R E S S U R E C H A R T 11 50 45 0 15 0 100 7 200 14 300 21 400 2...

Страница 12: ...oils vinegar sour HCs Black liquor hot water steam hot aliphatic amines ethylene oxide propylene oxide molten sodium molten potassium Simriz SZ485 formerly Aegis PF128 8 400 F 232 psig 200 C 16 bar 75...

Страница 13: ...t of a complete purchase order through the Expedite Ship Plan ESP 13 1 4 20 mA with HART 2 FOUNDATION fieldbus R 9 6 5 R96 Through Air Radar Level Transmitter 6 GHz Pulse Radar 1 BASIC MODEL NUMBER 5...

Страница 14: ...antennas 6 GHz TECHNOLOGY OPERATING FREQUENCY A TFE Material of Construction codes A B C and K only B Polypropylene Material of Construction codes A G K and L only C Halar Material of Construction co...

Страница 15: ...051 055 052 056 Polypropylene 057 061 058 062 059 063 060 064 TFE 065 069 066 070 067 071 068 072 15 53 3 150 ANSI raised face flange EA DN 80 PN 16 EN 1092 1 Type A 54 3 300 ANSI raised face flange E...

Страница 16: ...on MAGNETROL shall not be liable for misap plication labor claims direct or consequential damage or expense arising from the instal lation or use of equipment There are no other warranties expressed o...

Отзывы: