27
Control unit MGCplus
Digital inputs, digital outputs and relay outputs
Function
Description
Buzzer
To this output you connect a buzzer that does not generate its own beep
pattern. The buzzer generates the beep pattern depending on the switching
status of the output.
The output is set when the selected events occur. The events are selected
using the "Buzzer" parameter.
IMPORTANT! Assign this function to a digital output. When using a relay out-
put, the life of the dry contact may be shortened if the buzzer is switched on
frequently.
Alternatively, you may use the "Buzzer (static)" output.
Buzzer (static)
To this output you connect a buzzer with an integrated beep pattern.
The output is set when the selected events occur. The events are selected
using the "Buzzer" parameter.
In contrast to the "Buzzer" function, this output is set statically.
Passage clear
This output is activated when there is no person in the passage.
Passage clear D1
This output is activated if no person is detected in the passage who has en-
tered on side 1.
Passage clear D2
Function such as "Passage clear D1" but for direction 2.
Val. pers. present
This output is activated when a validated person is still in the passage.
Val. pers. present D1 This output is activated when a validated person, who entered on side 1, is
still in the passage.
Val. pers. present D2 Function such as "Val. pers. present 1" but for direction 2.
Val. pers. passed
This output generates a pulse with a duration of 300 m for each validated
person passing the passage.
Val. pers. Passed D1 Function such as "Val. pers. Passed 1" but only for direction 1.
Val. pers. Passed D2 Function such as "Val. pers. Passed 2" but only for direction 1.
Fraud
An unauthorised access attempt such as "Intrusion", "Wrong direction" or
"Tailgating" was detected in one direction.
Fraud direction 1
Function such as "Fraud" but only for direction 1.
Fraud direction 2
Function such as "Fraud" but only for direction 2.
Intrusion
An unauthorised access attempt of the "Intrusion", type was detected in one
direction.
Intrusion D1
Function such as "Intrusion" but only for direction 1.
Intrusion D2
Function such as "Intrusion" but only for direction 2.
Wrong direction
An unauthorised access attempt of the "Wrong direction", type was detect-
ed in one direction.
Wrong direction D1
Function such as "Wrong direction" but only for direction 1.
Wrong direction D2
Function such as "Wrong direction" but only for direction 2.