12
Control unit MGCplus
Definitions
Designation
Description
B1 to B14
Positioning of the light barriers (PE beams) 1 to 14.
Side 1
The "Side 1" corresponds to the "Paid" zone or the zone controlled
(protected area).
Side 2
The "Side 2" corresponds to the "Unpaid" zone or the zone not con-
trolled (unprotected area).
Passage
direction 1
The "Passage direction 1" corresponds to the passage direction
from the "Paid" zone to the "Unpaid" zone.
Passage
direction 2
The "Passage direction 2" corresponds to the passage direction
from the "Unpaid" zone to the "Paid" zone.
Table 4:
Definitions
2.2
Unauthorised access attempts
The control unit differentiates between different kinds of unauthorised access
attempts.
Designation
Description
Intrusion
A person without validation enters the pedestrian gate.
Tailgating
A person without validation attempts to follow a validated person.
Wrong direction An already validated person passes the pedestrian gate in direc-
tion 1, while a second person tries to enter in direction 2.
or
An already validated person passes the pedestrian gate in direc-
tion 2, while a second person tries to enter in direction 1.
Table 5:
Descriptions for "Unauthorised access attempts"