Assembly and installation
58
8.4.2 Induction
loops
The induction loops are available as ready assembled cables in
various lengths from MAGNETIC.
Alternatively a loop can be manufactured from single wire. The
following requirements must be fulfilled:
Wire cross section: 0.75 to 1.5 mm
2
Inductance of the loop: 70 to 500
μ
H. This is equivalent to a
loop with 3 to 6 windings.
When using hot pouring compounds, such as bitumen
temperature resistant loop cables/strands must be used.
8.4.3
Testing induction loops
To verify the contact resistance, insulation resistance, and
inductance of the loop these properties must be measured after
installation:
Contact resistance: 0.8 to 2.0 ohms
Insulation resistance to earth: > 1 Mohm.
Inductance of the loop: 70 to 500
μ
H
If the values are not within the specified ranges, the loop is
defective.
8.4.4 Installing
induction loops in bitumen, asphalt, or concrete
1. Cut a 50 mm deep groove into the surface or asphalt using a
cutting disc. The groove must be equally deep at every point.
According to Fig. 14 the corners of the groove must be cut in a
45° angle.
Mag00085
3
1
4
2
Fig. 19: Installing induction loop in bitumen, asphalt, or concrete
1
Groove for induction loop feed line
2
Corners cut diagonally
3
Groove for induction loop
4 Induction
loop