Magneti Marelli Smart Gas Скачать руководство пользователя страница 6

                                               

                                        

 

 
 

1161306-0 

27

In case of the Product sent for Repairing is not under Warranty, the Customer 
will be advised and will have to authorized the Repairing out-of-Warranty. 
The cost of the Repairing will be charged to the Customer. 
In  case  of  unjustified  demand  of  Warranty,  the  labor  cost  for  checking  and 
verifying the Product will be charged to the Customer. 
 
 

3   Product installation 

 
Take  the  instrument  out  of  the  package  and  follow  the  procedure  to 
carry out a vehicle first exhaust gas analysis in ten minutes. 

 

3.1   Power supply 

The  device  shall  be  powered  through  the  network  cable  supplied  with  the 
package. 
Insert  the  supply  cable  in  the  outlet  placed  in  the  instrument  rear  side,  as 
shown in the picture below. 

 

 

 
 
Turn on the instrument by pushing the rocker switch near the outlet. 

 

Содержание Smart Gas

Страница 1: ...1161306 0 22 Quick Start Smart Gas Logic Gas Gas analyzer Operating manual ENGLISH Rev 2 0...

Страница 2: ...____________________________________________30 4 2 Light test and gas official procedure _______________________31 4 2 1 Preliminary steps 31 4 2 2 Test start 31 4 2 3 HC test 32 4 2 4 Leak test 32 4...

Страница 3: ...1161306 0 24 1 Package contents Gas analyzer Smart Gas Logic Gas 220V supply cable Serial cable for connection to the PC Exhaust gas sampling probe Logbook...

Страница 4: ...lli After Market Parts and Services MM AM P S warrants the Product for 24 Twenty four Months starting from the date of the Product s activation or the date of the original purchase turning out by the...

Страница 5: ...e Document The Product will be returned back to the Customer in Carriage Forward Shipment 2 4 Warranty Exclusions The Warranty does not extend to degraded Parts caused by the wrong using of the Equipm...

Страница 6: ...ecking and verifying the Product will be charged to the Customer 3 Product installation Take the instrument out of the package and follow the procedure to carry out a vehicle first exhaust gas analysi...

Страница 7: ...exhaust pipe whereas the other side shall be connected to the analyzer The instrument gas inlet is situated on the condensate separator Connect the gas sampling probe as shown in the picture Arrow key...

Страница 8: ...alyzer Smart Gas switch on the display will show a short introduction message then the analyzer enters automatically in the main page where it is possible to select the type of test to be carried out...

Страница 9: ...bar will indicate the operation progress The warm up average time is of 3 5 minutes depending on the environment temperature At the end of the WARM UP the pump turns on and the display shows the mess...

Страница 10: ...ry steps Mandatory emission test you will be asked to select the vehicle engine type for any detail on the categories please refer to page 38 of the user manual Gas analysis Free page Light Test Offic...

Страница 11: ...lt be negative then the instrument will not start the Official Test or the Mandatory emission test 4 2 5 Test execution Follow the displayed instructions Once the gas sampling probe has been introduce...

Страница 12: ...guration menu when you want to change the settings date and time modification and each time you modify the used configuration for example when you pass form a rev counter with pliers to a M C T C NET...

Страница 13: ...l message display at instrument switch on press the ESC or F function key if you are in the instrument main menu press the ESC key twice Select the Set up item and press the key to confirm Set up Serv...

Страница 14: ...as values will remain displayed to facilitate the operation when you are connected with a computer Once the communication with the Computer is interrupted the instrument can be locally reused only aft...

Страница 15: ...the installation of the Greek version Select the first item for all the other kinds of installation Only one of the 3 options can be selected If the product is installed with the Bluetooth option sele...

Страница 16: ...de supplied with the CD it is written on the CD cover Do not carry out any operation until the end of the installation 7 Software use on PC Select the programme icon present on the desktop or which ca...

Страница 17: ...etooth Pairing module In case the product is fitted with Bluetooth communication system with commercial Bluetooth module installed on the PC the wireless module shall be configured in order to associa...

Страница 18: ...earch for nearby devices Select the required language Once the search is ended the window shown in the figure will be displayed If one or more products have been found in the area they will be highlig...

Страница 19: ...as follows to clean the instrument Make sure that the multiple outlet switch is OFF WARNING Do not clean the inside part of the condensate separator chambers with alcohol Check the filter see picture...

Страница 20: ...1161306 0 41 Clean the gas sam...