Page 1 of 1
Addendum #: 147-20054 R0
February 2015
LaserGuard2 Systems
LaserGuard2 Systems Using a Special Laser
Addendum to:
LaserGuard2 Collision Avoidance System Instruction Manual (147-20004)
A special laser will be marked with a label to indicate it has a sensing distance that deviates from the
standard distance of 5 to 150 ft.
A laser with a label of “147-20051 SPC LASER” or “147-20061 SPC LASER” has a sensing distance of 8
in. to 150 ft.
When setting up a trip point close to the minimum sensing distance, it is important to keep in mind the
hysteresis inherent with the LaserGuard2 system. The LaserGuard2 system has about 1 ft. hysteresis
around the point where the trip points are set. For instance, if the crane is physically moved so the laser
and reflector have 10 ft. between them and the Stop button is pressed, the Stop relay will turn on at 11 ft.
and turn off at 9 ft.
NOTE: When setting up a Stop trip point, it is important to move the crane at least one foot farther away
than the desired stopping point.
Distributed by Ergonomic Partners | [email protected] | (314) 884-8884 | www.ErgonomicPartners.com
Содержание LaserGuard2 LG2-H-4
Страница 12: ...LaserGuard2 Instruction Manual April 2015 Page 12 of 31 Figure 3 Mounting Bracket Dimensions in mm ...
Страница 13: ...LaserGuard2 Instruction Manual April 2015 Page 13 of 31 Figure 4 Mounting Instructions ...
Страница 18: ...LaserGuard2 Instruction Manual April 2015 Page 18 of 31 Figure 10 Laser Support Unit Wiring for LG2 H 4 ...
Страница 19: ...LaserGuard2 Instruction Manual April 2015 Page 19 of 31 Figure 11 Laser Support Unit Wiring for LG2 L 4 ...
Страница 24: ...LaserGuard2 Instruction Manual April 2015 Page 24 of 31 4 Installation Diagrams Figure 13 Component Locations ...