Table 5-2: DC Bus Regulation
Table 5-3: V/f Parameters
VFD Voltage
E01.01 Setting
Overvoltage Trip
Braking Transistor
Trip
Reset
On
Off
230
150-255
400V
380V
380V
375V
460
≥
400
800V
760V
760V
750V
460
<400
720V
680V
660V
650V
Parameter
Name
Function
Range
Default
E01.03
V/f Pattern
V/f Pattern Selection
00–0F, FF
04*
0 60Hz, Level 0
1 60Hz, Level 1
2 60Hz, Level 2
3 60Hz, Level 3
4 60Hz, Level 4
5 60Hz, Level 5
6 60Hz, Level 6
7 60Hz, Level 7
8 60Hz, Level 8
9 50Hz, Level 0
A 50Hz, Level 2
B 50Hz, Level 4
C 50Hz, Level 6
D 75Hz, Level 4
E 90Hz, Level 4
F Custom
FF Custom w/o Limit
E01.04***
Max Frequency
Maximum Frequency
20.0–150.0 Hz
**
E01.05
Max Voltage
Maximum Voltage
0.0–510.0 V
**
E01.06
Base Frequency
Motor Base Frequency
0.0–150.0 Hz
**
E01.07
Mid Frequency A
Midpoint Output
Frequency A
0.0–150.0 Hz
**
E01.08
Mid Voltage A
Midpoint Frequency
Voltage A
0.0–510.0 V
**
E01.09
Min Frequency
Minimum Frequency
0.0–150.0 Hz
**
E01.10
Min Voltage
Minimum Voltage
0.0–510.0 V
**
E01.11
Mid Frequency B
Midpoint Output Frequency B
0.0–150.0 Hz
0.0
E01.12
Mid Voltage B
Midpoint Output
Voltage B
0.0–510.0 V
0.0
E01.13
Base Voltage
Motor Base Voltage
0.0–510.0 V
0.0
* Initial value determined by X-Press Programming
** Initial value determined by voltage class and setting of E01.03.
and
.
*** To change E01.04 “Max Frequency,” E01.03 must first be set to “0F”, or pick a V/f pattern from
.
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...