2.4 Installing the VFD (Recommended Clearances)
The following two figures show the recommended minimum clearances when mounting the VFD in standard or
side-by-side installations. If the recommended clearances cannot be met, decreased airflow may reduce the life of
the VFD.
Figure 2-5: Standard Installation
2.5 Installing the VFD (Side-by-Side)
It is recommended to set parameter L08.35 = 1 when mounting VFDs in a side-by-side configuration. This provides
a more conservative OL2 overload protection.