Motor A5 Submenu
74
Motor A5 Submenu
This sub-menu contains parameters, which are
programmed with information about the motor
being controlled by the drive.
IMPORTANT
The parameters in this sub-menu defined the
motor model, which is very important for
proper operation. Ensure that the data is
accurate.
NOTE: When
Hidden Item
appears above a
parameter description, it indicates that its
appearance in the list is controlled by the
HIDDEN ITEMS setting.
See details on page
NOTE: When
Run lock out
appears above a
parameter description, the parameter cannot
be changed when the drive is in the RUN
mode.
Parameter
[
Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Motor ID
[A501]
(Motor Identification) This parameter
allows for the selection of motor
parameters. A listing of each Motor ID
with its corresponding set of motor
parameters is shown below.
motor parameter
Motor ID
4 pole
dflt
i,
iii
6 pole
dflt
i,
iii
Rated Mtr Power 0.0 HP
0.0 HP
Rated Mtr Volts
0.0 V
0.0 V
Rated Excit Freq 0.0 Hz
0.0 Hz
Rated Motor Curr 0.0 A
0.0 A
Motor Poles
0
0
Rated Mtr Speed 0.0 rpm 0.0 rpm
% No Load Curr
35.00% 45.00%
Stator Leakage X 9.00%
7.50%
Rotor Leakage X 9.00%
7.50%
Stator Resist
1.50%
1.50%
Motor Iron Loss
0.50%
0.50%
Motor Mech Loss 1.00%
1.00%
Flux Sat Break
75%
75%
Flux Sat Slope 1
0%
0%
Flux Sat Slope 2
50%
50%
NOTE: The default motor selections need
to have the motor nameplate information
entered in the appropriate motor
parameters. The other motor parameters
are already set to nominal values.
IMPORTANT
Whichever Motor ID is used, the Adaptive
Tune Procedure should be followed to
obtain maximum motor performance.
See
Using the Adaptive Tune on page 152 or
Auto Tune on page ix to Obtain Maximum
Motor Performance.
none
4 pole dflt
i,
ii
[1]
i
6 pole dflt
i,
ii
[2]
i
PM dflt
ii
[3]
4 POLE
DFLT
i,
iii
4 POLE
DFLT
i,
iii
N
i
Y
i
PM
Dflt
ii
PM
Dflt
ii
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation
Table 13: Motor ID Defaults
Содержание HPV 900 Series 2
Страница 4: ......
Страница 195: ...APPENDIX Dimensions Mounting Holes Weights 173 Figure 46 Frame 2 Dimensions Mounting Holes and Weight...
Страница 196: ...APPENDIX Dimensions Mounting Holes Weights 174 Figure 47 Frame 3 Dimensions Mounting Holes and Weight...
Страница 197: ...APPENDIX Dimensions Mounting Holes Weights 175 Figure 48 Frame 3 5 Dimensions Mounting Holes and Weight...
Страница 198: ...APPENDIX Dimensions Mounting Holes Weights 176 Figure 49 Frame 4 Dimensions Mounting Holes and Weight...
Страница 199: ...APPENDIX Dimensions Mounting Holes Weights 177 Figure 50 Frame 5 Dimensions Mounting Holes and Weight...
Страница 227: ...205 Z Z MARKER LOST 150 Zero Speed Level parameter 47 Zero Speed logic output 105 Zero Speed Time parameter 47...
Страница 228: ......
Страница 229: ......